BACKGROUND: Limited data are available on the accuracy of quantification methods for left atrial (LA) volumes using two-dimensional (2D) and particularly real-time three-dimensional echocardiographic (RT3DE) methods in comparison with a reference standard. The aim of this study was to perform a head-to-head comparison between 2D and RT3DE methods with magnetic resonance imaging (MRI) as the reference standard.
METHODS: LA volumes derived from 2D echocardiographic methods (i.e., biplane modified Simpson's, biplane area-length, and prolate ellipse methods) and from RT3DE methods (i.e., 4D LA Analysis and QLAB) in 60 consecutive patients were compared with MRI measurements. Offline analysis time was recorded.
RESULTS: The biplane modified Simpson's and area-length methods showed good intraclass correlations with MRI for maximum (r = 0.70 and r = 0.69, P < .001) and minimum (r = 0.83 and r = 0.82, P < .001) volumes. Although RT3DE methods led to moderate increases in correlations for maximum (r = 0.94 and 0.70, P < .001) and minimum (r = 0.95 and r = 0.90, P < .001) volumes and narrower Bland-Altman limits of agreement than 2D echocardiographic methods, offline analysis time was higher for RT3DE (155-161 vs 103-144 sec). Compared with MRI, maximum and minimum LA volumes were underestimated by -4.7% and -8.9%, respectively, using 4D LA Analysis, by -15.7% and -14.9% using QLAB, by -12.3% and -4.4% using the biplane Simpson's method, by -13.7% and -6.8% using the area-length method, and by -48.2% and -50.5% using the prolate ellipse method.
CONCLUSIONS: The biplane Simpson's and area-length methods offer reasonable accuracy for LA chamber quantification across a broad range of volumes, while RT3DE methods lead to a moderate improvement in accuracy at the cost of more elaborate offline analysis.
Copyright © 2013 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23411366     DOI: 10.1016/j.echo.2013.01.001

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  8 in total

1.  Evaluation of left atrial volume and function in patients with coronary slow flow phenomenon using real-time three-dimensional echocardiography.

Authors:  Yumeng Xing; Yongle Chen; Yu Liu; Dehong Kong; Yan Yan; Xianhong Shu; Cuizhen Pan
Journal:  Int J Cardiovasc Imaging       Date:  2019-07-25       Impact factor: 2.357

2.  Prognostic value of real-time three-dimensional echocardiography compared to two-dimensional echocardiography in patients with systolic heart failure.

Authors:  Frederico J N Mancuso; Valdir A Moises; Dirceu R Almeida; Dalva Poyares; Luciana J Storti; Flavio S Brito; Sergio Tufik; Angelo A V de Paola; Antonio C C Carvalho; Orlando Campos
Journal:  Int J Cardiovasc Imaging       Date:  2017-11-02       Impact factor: 2.357

Review 3.  Standardization of normal values for cardiac chamber size in echocardiography.

Authors:  Tatsuya Miyoshi; Hidekazu Tanaka
Journal:  J Med Ultrason (2001)       Date:  2021-11-17       Impact factor: 1.314

4.  Three-Dimensional Echocardiography in Evaluating LA Volumes and Functions in Diabetic Normotensive Patients without Symptomatic Cardiovascular Disease.

Authors:  Mohamed Hamza; Ahmed Mamdouh; Dina Ezzeldin; Adnan Tawfik; Ahmed Nayel
Journal:  Int J Vasc Med       Date:  2020-08-19

Review 5.  Principles of transthoracic echocardiographic evaluation.

Authors:  Anita C Boyd; Nelson B Schiller; Liza Thomas
Journal:  Nat Rev Cardiol       Date:  2015-04-28       Impact factor: 32.419

6.  Single breath-hold 3D measurement of left atrial volume using compressed sensing cardiovascular magnetic resonance and a non-model-based reconstruction approach.

Authors:  Orestis Vardoulis; Pierre Monney; Amit Bermano; Amir Vaxman; Craig Gotsman; Janine Schwitter; Matthias Stuber; Nikolaos Stergiopulos; Juerg Schwitter
Journal:  J Cardiovasc Magn Reson       Date:  2015-06-11       Impact factor: 5.364

7.  Evaluation of left atrial volume and function in systemic sclerosis patients using speckle tracking and real-time three-dimensional echocardiography.

Authors:  Halil Ataş; Alper Kepez; Kürşat Tigen; Fuad Samadov; Gülsen Özen; Altuğ Cincin; Murat Sünbül; Mehmet Bozbay; Haner Direşkeneli; Yelda Başaran
Journal:  Anatol J Cardiol       Date:  2015-07-03       Impact factor: 1.596

8.  Automated quantification of left atrial size using three-beat averaging real-time three dimensional Echocardiography in patients with atrial fibrillation.

Authors:  Ran Heo; Geu-Ru Hong; Young-Jin Kim; Joel Mancina; In-Jeong Cho; Chi Young Shim; Hyuk-Jae Chang; Jong-Won Ha; Namsik Chung
Journal:  Cardiovasc Ultrasound       Date:  2015-08-25       Impact factor: 2.062

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.