Literature DB >> 23411124

New disposable forehead electrode set with excellent signal quality and imaging compatibility.

Sami Myllymaa1, Pasi Lepola, Juha Töyräs, Taina Hukkanen, Esa Mervaala, Reijo Lappalainen, Katja Myllymaa.   

Abstract

The use of emergency electroencephalography (EEG) in clinical practice is limited in part due to the lack of commercially available EEG monitoring sets that are suitable for rapid and simple use. The aim of this study was to develop a rapid and simple-to-use disposable forehead EEG electrode set for routine use that is also suitable for long-term monitoring. The EEG set we developed consists of 12 hydrogel-coated electrodes (10 recording electrodes, plus a reference and ground electrode) attached to a solid polymer film. The developed EEG set was compared to the full conventional 10-20 electrode setup in terms of the ability to detect epileptiform abnormalities in two critically ill patients. The technical quality of the EEG signal from the newly developed electrode set was excellent, and status epilepticus was reliably detected with this EEG set. Electric performance testing showed that the impedance spectra of the developed EEG electrodes were comparable to those of three commercially available, disposable electrodes, and the noise level was lower than that of the commercial electrodes. The developed EEG set is also MRI and CT compatible and lacks any signs of imaging artefacts or heat induction. These promising results provide a reason to expect that the developed EEG set may be applicable to situations in which the full, conventional 10-20 electrode setup is not available.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23411124     DOI: 10.1016/j.jneumeth.2013.02.003

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  6 in total

1.  A Handy EEG Electrode Set for patients suffering from altered mental state.

Authors:  Pasi Lepola; Sami Myllymaa; Juha Töyräs; Taina Hukkanen; Esa Mervaala; Sara Määttä; Reijo Lappalainen; Katja Myllymaa
Journal:  J Clin Monit Comput       Date:  2015-01-10       Impact factor: 2.502

2.  Forehead electrodes sufficiently detect propofol-induced slow waves for the assessment of brain function after cardiac arrest.

Authors:  Jukka Kortelainen; Eero Väyrynen; Ilkka Juuso; Jouko Laurila; Juha Koskenkari; Tero Ala-Kokko
Journal:  J Clin Monit Comput       Date:  2019-02-20       Impact factor: 2.502

Review 3.  Electrophysiologic monitoring in acute brain injury.

Authors:  Jan Claassen; Paul Vespa
Journal:  Neurocrit Care       Date:  2014-12       Impact factor: 3.210

4.  Unobtrusive ambulatory EEG using a smartphone and flexible printed electrodes around the ear.

Authors:  Stefan Debener; Reiner Emkes; Maarten De Vos; Martin Bleichner
Journal:  Sci Rep       Date:  2015-11-17       Impact factor: 4.379

5.  Novel wireless electroencephalography system with a minimal preparation time for use in emergencies and prehospital care.

Authors:  Andrei Jakab; Antti Kulkas; Timo Salpavaara; Pasi Kauppinen; Jarmo Verho; Hannu Heikkilä; Ville Jäntti
Journal:  Biomed Eng Online       Date:  2014-05-08       Impact factor: 2.819

Review 6.  Signal acquisition and analysis of ambulatory electromyographic recordings for the assessment of sleep bruxism: A scoping review.

Authors:  Magdalini Thymi; Frank Lobbezoo; Ghizlane Aarab; Jari Ahlberg; Kazuyoshi Baba; Maria Clotilde Carra; Luigi M Gallo; Antoon De Laat; Daniele Manfredini; Gilles Lavigne; Peter Svensson
Journal:  J Oral Rehabil       Date:  2021-05-02       Impact factor: 3.558

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.