Common hand sanitizer may distort readings of breathalyzer tests in the absence of acute intoxication.

Syed S Ali1, Michael P Wilson, Edward M Castillo, Peter Witucki, Todd T Simmons, Gary M Vilke.   

Abstract

OBJECTIVES: The use of alcohol-based hand sanitizers has recently become widespread. To the authors' knowledge, no previous study has examined whether application of ethanol-based hand sanitizers by the person operating a common breathalyzer machine will affect the accuracy of the readings. This was a prospective study investigating whether the use of hand sanitizer applied according to manufacturer's recommendations (Group I), applied improperly at standard doses (Group II), or applied improperly at high doses (Group III) had an effect on breathalyzer readings of individuals who had not ingested alcohol.
METHODS: The participants of the prospective study were divided into three groups to assess the effect of hand sanitizer on breathalyzer readings. Group I used one pump (1.5 mL) of hand sanitizer (Purell), allowing the hands to dry per manufacturer's recommendations; Group II used one pump (1.5 mL), without allowing the hands to dry; and Group III used two pumps (3 mL), without allowing the hands to dry. Breathalyzer measures for each group are presented as medians with interquartile ranges (IQR) and ranges. Differences between each sequential group (I vs. II and II vs. III) were assessed using a Mann-Whitney U-test (p < 0.05 significant).
RESULTS: There were 25 study participants in each group for a total of 75 participants. The initial breathalyzer readings of all study participants were 0.000 g/dL. The median breathalyzer reading was 0.004 g/dL in Group I (IQR = 0.001 to 0.008 g/dL), 0.051 g/dL in Group II (IQR = 0.043 to 0.064 g/dL), and 0.119 g/dL in Group III (IQR = 0.089 to 0.134 g/dL). Measures between each subsequent group were all statistically different (p < 0.001).
CONCLUSIONS: The use of common alcohol-based hand sanitizer may cause false-positive readings with a standard hospital breathalyzer when the operator uses the hand sanitizer correctly. The breathalyzer readings are further elevated if more sanitizer is used or if it is not allowed to dry appropriately.
© 2013 by the Society for Academic Emergency Medicine.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23406081     DOI: 10.1111/acem.12073

Source DB:  PubMed          Journal:  Acad Emerg Med        ISSN: 1069-6563            Impact factor:   3.451


  6 in total

Review 1.  Inhalation of Alcohol Vapor: Measurement and Implications.

Authors:  Robert Ross MacLean; Gerald W Valentine; Peter I Jatlow; Mehmet Sofuoglu
Journal:  Alcohol Clin Exp Res       Date:  2017-01-05       Impact factor: 3.455

2.  Wearable Electrochemical Alcohol Biosensors.

Authors:  Alan S Campbell; Jayoung Kim; Joseph Wang
Journal:  Curr Opin Electrochem       Date:  2018-05-23

3.  Commentary on: ethyl glucuronide and ethyl sulfate assays in clinical trials, interpretation, and limitations: results of a dose ranging alcohol challenge study and 2 clinical trials.

Authors:  Raymond F Anton
Journal:  Alcohol Clin Exp Res       Date:  2014-06-24       Impact factor: 3.455

4.  Ethanol-based disinfectant sprays drive rapid changes in the chemical composition of indoor air in residential buildings.

Authors:  Jinglin Jiang; Xiaosu Ding; Kristofer P Isaacson; Antonios Tasoglou; Heinz Huber; Amisha D Shah; Nusrat Jung; Brandon E Boor
Journal:  J Hazard Mater Lett       Date:  2021-09-08

5.  Driving under the influence of alcohol during the COVID-19 pandemic.

Authors:  Sorin Hostiuc; Doina Radu; Lidia Seretean; Cosmin Tirdea; Răzvan Siminiuc; George Cristian Curcă
Journal:  Forensic Sci Int       Date:  2021-10-23       Impact factor: 2.395

Review 6.  A Review on Flexible Electrochemical Biosensors to Monitor Alcohol in Sweat.

Authors:  Nuna G Costa; Joana C Antunes; Antonio J Paleo; Ana M Rocha
Journal:  Biosensors (Basel)       Date:  2022-04-16
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.