Changes in upper limb extracellular water content 
during hemodialysis measured by multi-frequency bioimpedance.

Sanjeev Kumar1, Maryam Khosravi, Annick Massart, Madhu Potluri, Andrew Davenport.   

Abstract

INTRODUCTION: Hemodialysis patients are at risk of chronic volume overload, with consequent increased cardiovascular morbidity and mortality. Multifrequency bioimpedance allows assessment of body fluid volumes. Devices vary from two paired electrodes which measure bioimpedance down one side of the body to four paired electrodes which measure both sides of the body. As arteriovenous fistulae may cause arm swelling, we investigated whether the presence of a fistula affected bioimpedance limb measurements.
METHODS: We audited the change in extracellular water (ECW) and total body water (TBW) in the arms following hemodialysis in 414 adult patients attending for routine mid-week hemodialysis session 
by multifrequency bioimpedance using a four-paired electrode bioimpedance device (InBody 720; Biospace, Seoul, South Korea).
RESULTS: Patients with right-sided brachial fistulae had a greater percentage ECW/TBW in the fistula arm both prior to and post dialysis compared to those dialyzing with catheters (pre 39.6 ± 3.5 vs. 38.4.3 ± 1.6 and post 38.5 ± 1.3 vs. 37.8 ± 1.1, p<0.01), but there was no difference in the ECW/TBW in the non-fistula arm, pre dialysis between those dialyzing with fistulae compared to catheters, but the ECW/TBW was greater post dialysis with both brachial (38.4 ± 1.1) and radial fistulae (38.1 ± 1.3) compared to those with catheters (37.7 ± 0.9, p<0.05 respectively).
CONCLUSIONS: Although absolute and also relative extracellular fluid volumes are increased in the fistula arm of hemodialysis patients, particularly right-sided and with brachial fistulae, the amount of fluid is unlikely to be of clinical significance when making bioimpedance measurements in the non-fistula side of the body to determine volume status.

Entities:  

Mesh:

Year:  2013        PMID: 23404642     DOI: 10.5301/IJAO.5000190

Source DB:  PubMed          Journal:  Int J Artif Organs        ISSN: 0391-3988            Impact factor:   1.595


  4 in total

1.  Can non-invasive measurements aid clinical assessment of volume in patients with cirrhosis?

Authors:  Andrew Davenport; Banwari Argawal; Gavin Wright; Konstantinos Mantzoukis; Rumyana Dimitrova; Joseph Davar; Panayota Vasianopoulou; Andrew K Burroughs
Journal:  World J Hepatol       Date:  2013-08-27

2.  Changes in muscle and fat mass with haemodialysis detected by multi-frequency bioelectrical impedance analysis.

Authors:  K Panorchan; A Nongnuch; S El-Kateb; C Goodlad; A Davenport
Journal:  Eur J Clin Nutr       Date:  2015-06-03       Impact factor: 4.016

3.  Dialysis: Bioimpedance spectroscopy for assessment of fluid overload.

Authors:  Andrew Davenport
Journal:  Nat Rev Nephrol       Date:  2013-03-26       Impact factor: 28.314

4.  Wearing a face mask during controlled-intensity exercise is not a risk factor for exertional heatstroke: A pilot study.

Authors:  Taigo Sakamoto; Hiroyuki Narita; Kensuke Suzuki; Hirofumi Obinata; Kei Ogawa; Ryotaro Suga; Haruka Takahashi; Mayumi Nakazawa; Marina Yamada; Satoo Ogawa; Hiroyuki Yokota; Shoji Yokobori
Journal:  Acute Med Surg       Date:  2021-11-26
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.