Literature DB >> 23403398

Laser speckle contrast imaging for assessment of liver microcirculation.

Christian Sturesson1, Dan M J Milstein, Ivo C J H Post, Adrie M Maas, Thomas M van Gulik.   

Abstract

OBJECTIVE: Laser speckle contrast imaging (LSCI) is a novel technique for microcirculation imaging not previously used in the liver. The aim of the present experimental study was to evaluate the use of LSCI for assessing liver microcirculation.
MATERIALS AND METHODS: In six male Wistar rats, the median liver lobe was exposed through a midline laparotomy. Liver blood perfusion was measured simultaneously with LSCI and sidestream dark-field (SDF) imaging at baseline and during sequential temporary occlusions of the portal vein, hepatic artery, and total blood inflow occlusion. Both the inter-individual variability associated with perfusion sampling area and comparisons in perfusion measurements between both imaging techniques were investigated and validated for the application of LSCI in the liver.
RESULTS: Occlusion of the hepatic artery, portal vein, and total inflow occlusion resulted in a significant decrease in LSCI signal to 74.7±6.4%, 15.0±2.3%, and 10.4±0.5% respectively (p<0.005 vs. baseline). The LSCI perfusion units correlated with sinusoidal blood flow velocity as measured with SDF imaging (Pearson's r=0.94, p<0.001). In a 10 mm diameter region of interest, as measured with LSCI, baseline inter-individual variability measured by the coefficient of variability was 13%.
CONCLUSION: Alterations in LSCI signal during sequential inflow occlusions were in accordance with previously published results on hepatic hemodynamics in the rat and correlated well with our SDF imaging-derived sinusoidal blood flow velocity measurements. We found that LSCI was able to produce reproducible real-time blood perfusion measurements of hepatic microcirculation. Compared to established techniques for liver blood perfusion measurements LSCI holds the advantages of non-contact measurements over large surfaces with a high speed of data acquisition.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23403398     DOI: 10.1016/j.mvr.2013.01.004

Source DB:  PubMed          Journal:  Microvasc Res        ISSN: 0026-2862            Impact factor:   3.514


  13 in total

1.  Design and evaluation of a miniature laser speckle imaging device to assess gingival health.

Authors:  Caitlin Regan; Sean M White; Bruce Y Yang; Thair Takesh; Jessica Ho; Cherie Wink; Petra Wilder-Smith; Bernard Choi
Journal:  J Biomed Opt       Date:  2016-10-01       Impact factor: 3.170

2.  Laser speckle imaging based on photothermally driven convection.

Authors:  Caitlin Regan; Bernard Choi
Journal:  J Biomed Opt       Date:  2016-02       Impact factor: 3.170

3.  In vivo imaging of hepatic hemodynamics and light scattering property during ischemia-reperfusion in rats based on spectrocolorimetry.

Authors:  Sharmin Akter; Satoko Kawauchi; Shunichi Sato; Suefumi Aosasa; Junji Yamamoto; Izumi Nishidate
Journal:  Biomed Opt Express       Date:  2017-01-19       Impact factor: 3.732

4.  Real-time, label-free, intraoperative visualization of peripheral nerves and micro-vasculatures using multimodal optical imaging techniques.

Authors:  Jaepyeong Cha; Aline Broch; Scott Mudge; Kihoon Kim; Jung-Man Namgoong; Eugene Oh; Peter Kim
Journal:  Biomed Opt Express       Date:  2018-02-12       Impact factor: 3.732

5.  Multichannel imaging to quantify four classes of pharmacokinetic distribution in tumors.

Authors:  Sumit Bhatnagar; Emily Deschenes; Jianshan Liao; Cornelius Cilliers; Greg M Thurber
Journal:  J Pharm Sci       Date:  2014-07-21       Impact factor: 3.534

6.  The use of pulse pressure variation for predicting impairment of microcirculatory blood flow.

Authors:  Christoph R Behem; Michael F Graessler; Till Friedheim; Rahel Kluttig; Hans O Pinnschmidt; Anna Duprée; E Sebastian Debus; Daniel A Reuter; Sabine H Wipper; Constantin J C Trepte
Journal:  Sci Rep       Date:  2021-04-28       Impact factor: 4.379

7.  Laser speckle contrast imaging for intraoperative assessment of liver microcirculation: a clinical pilot study.

Authors:  Sam Eriksson; Jan Nilsson; Gert Lindell; Christian Sturesson
Journal:  Med Devices (Auckl)       Date:  2014-07-25

8.  Establishment of a rat model of portal vein ligation combined with in situ splitting.

Authors:  Libin Yao; Chonghui Li; Xinlan Ge; Hongdong Wang; Kesen Xu; Aiqun Zhang; Jiahong Dong
Journal:  PLoS One       Date:  2014-08-21       Impact factor: 3.240

Review 9.  Non-invasive imaging of microcirculation: a technology review.

Authors:  Sam Eriksson; Jan Nilsson; Christian Sturesson
Journal:  Med Devices (Auckl)       Date:  2014-12-09

10.  Preserving low perfusion during surgical liver blood inflow control prevents hepatic microcirculatory dysfunction and irreversible hepatocyte injury in rats.

Authors:  Chong-Hui Li; Yong-Wei Chen; Yong-Liang Chen; Li-Bin Yao; Xin-Lan Ge; Ke Pan; Ai-Qun Zhang; Jia-Hong Dong
Journal:  Sci Rep       Date:  2015-09-24       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.