Literature DB >> 23397197

A comparison of outcomes and dislocation rates using dual articulation cups and THA for intracapsular femoral neck fractures.

Sarunas Tarasevicius1, Otto Robertsson, Paulius Dobozinskas, Hans Wingstrand.   

Abstract

Total hip arthroplasty for intracapsular femoral neck fractures (FNF) is associated with a greater risk of dislocation. Dual articulation systems in this group of patients may provide better implant stability and a reduced dislocation rate. The aim of our study was to investigate FNF patients treated with dual articulation cups (DAC) and conventional THA and compare their clinical results at four months and one year after surgery. Our study compared femoral neck fracture patients treated with either DAC or conventional THA during two different time periods. Before surgery and during follow-up, the patients answered questions regarding their mobility, pain and usage of walking aids. Additionally at four-month and one-year follow-ups EQ-5D and HOOS questionnaires were applied for those patients qualifying for functional and quality of life analysis. Out of 125 femoral neck fracture patients 58 were treated with DAC and 67 with conventional THA. At four months and one year follow-up the HOOS and EQ-5D results did not differ significantly between DAC and conventional THA. Five hips in the THA group were revised for recurrent dislocation and two had a single dislocation. One year after surgery, the functional result of DAC and conventional THA are comparable but DAC have a lower risk of dislocation.

Entities:  

Mesh:

Year:  2013        PMID: 23397197     DOI: 10.5301/HIP.2013.10632

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   2.135


  18 in total

1.  In total hip arthroplasty via the direct anterior approach, a dual-mobility cup prevents dislocation as effectively in hip fracture as in osteoarthritis.

Authors:  Yasuhiro Homma; Tomonori Baba; Yu Ozaki; Taiji Watari; Hideo Kobayashi; Hironori Ochi; Mikio Matsumoto; Kazuo Kaneko
Journal:  Int Orthop       Date:  2016-11-11       Impact factor: 3.075

2.  Do Dual-mobility Cups Reduce Revision Risk in Femoral Neck Fractures Compared With Conventional THA Designs? An International Meta-analysis of Arthroplasty Registries.

Authors:  John E Farey; James Masters; Alana R Cuthbert; Pernille Iversen; Liza N van Steenbergen; Heather A Prentice; Sam Adie; Adrian Sayers; Michael R Whitehouse; Elizabeth W Paxton; Matthew L Costa; Søren Overgaard; Cecilia Rogmark; Ola Rolfson; Ian A Harris
Journal:  Clin Orthop Relat Res       Date:  2022-06-16       Impact factor: 4.755

3.  Clinical Outcomes of Total Hip Arthroplasty With the Anterolateral Modified Watson-Jones Approach for Displaced Femoral Neck Fractures.

Authors:  Naoki Takemoto; Takuya Nakamura; Katsura Kagawa; Yoshinobu Maruhashi; Takeshi Sasagawa; Kiyonobu Funaki; Takao Aikawa; Daiki Yamamoto
Journal:  Geriatr Orthop Surg Rehabil       Date:  2022-10-15

4.  The efficacy of dual-mobility cup in preventing dislocation after total hip arthroplasty: a systematic review and meta-analysis of comparative studies.

Authors:  Matteo Romagnoli; Alberto Grassi; Giuseppe Gianluca Costa; Lionel E Lazaro; Mirco Lo Presti; Stefano Zaffagnini
Journal:  Int Orthop       Date:  2018-07-21       Impact factor: 3.075

Review 5.  Risk of revision and dislocation in single, dual mobility and large femoral head total hip arthroplasty: systematic review and network meta-analysis.

Authors:  Kwanchai Pituckanotai; Alisara Arirachakaran; Harit Tuchinda; Chinundorn Putananon; Nitiphol Nualsalee; Kittipong Setrkraising; Jatupon Kongtharvonskul
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-11-08

6.  Dual mobility hip arthroplasty provides better outcomes compared to hemiarthroplasty for displaced femoral neck fractures: a retrospective comparative clinical study.

Authors:  Yong Tae Kim; Je-Hyun Yoo; Min Ki Kim; Sanghyun Kim; Jihyo Hwang
Journal:  Int Orthop       Date:  2018-01-17       Impact factor: 3.075

7.  Total Hip Arthroplasty (THA) for Femoral Neck Fractures: Comparison between Standard and Dual Mobility Implants.

Authors:  Riccardo L Alberio; Mattia Rusconi; Loris Martinetti; Diego Monzeglio; Federico A Grassi
Journal:  Geriatrics (Basel)       Date:  2021-07-07

8.  The use of a dual mobility cup in the management of recurrent dislocations of hip hemiarthroplasty.

Authors:  Christian Carulli; Armando Macera; Fabrizio Matassi; Roberto Civinini; Massimo Innocenti
Journal:  J Orthop Traumatol       Date:  2015-07-18

9.  Risk factors and modes of failure in the modern dual mobility implant. A systematic review and meta-analysis.

Authors:  Fu-Yuan Pai; Hsuan-Hsiao Ma; Te-Feng Arthur Chou; Tsan-Wen Huang; Kuo-Chin Huang; Shang-Wen Tsai; Cheng-Fong Chen; Wei-Ming Chen
Journal:  BMC Musculoskelet Disord       Date:  2021-06-14       Impact factor: 2.362

10.  The Warwick Hip Trauma Evaluation Two -an abridged protocol for the WHiTE Two Study: An embedded randomised trial comparing the Dual-Mobility withpolyethylene cups in hip arthroplasty for fracture.

Authors:  X L Griffin; J McArthur; J Achten; N Parsons; M L Costa
Journal:  Bone Joint Res       Date:  2013-10-02       Impact factor: 5.853

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.