Literature DB >> 23397186

Transarterial embolization of type II endoleaks after EVAR: the role of ethylene vinyl alcohol copolymer (Onyx).

René Müller-Wille1, Walter A Wohlgemuth, Peter Heiss, Philipp Wiggermann, Oliver Güntner, Andreas G Schreyer, Patrick Hoffstetter, Christian Stroszczynski, Niels Zorger.   

Abstract

PURPOSE: To determine the feasibility and efficacy of transarterial endoleak embolization using the liquid embolic agent ethylene vinyl alcohol copolymer (Onyx).
METHODS: Over a 7-year period eleven patients (6 women, 5 men; mean age 68 years, range 37-83 years) underwent transarterial embolization of a type II endoleak after endovascular aortic aneurysm repair using the liquid embolic agent Onyx. Two patients (18 %) had a simple type II endoleak with only one artery in communication with the aneurysm sac, whereas 9 patients (82 %) had a complex type II endoleak with multiple communicating vessels. We retrospectively analyzed the technical and clinical success of transarterial type II endoleak embolization with Onyx. Complete embolization of the nidus was defined as technical success. Embolization was considered clinically successful when volume of the aneurysm sac was stable or decreased on follow-up CT scans. RESULT: Mean follow-up time was 26.0 (range 6-50) months. Clinical success was achieved in 8 of 11 patients (73 %). Transarterial nidus embolization with Onyx was technically successful in 6 of 11 patients (55 %). In three cases the nidus was embolized without direct catheterization from a more distal access through the network of collateral vessels.
CONCLUSION: Onyx is a favorable embolic agent for transarterial endoleak embolization. To achieve the best clinical results, complete occlusion of the nidus is mandatory.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23397186     DOI: 10.1007/s00270-013-0567-5

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  6 in total

Review 1.  [Endovascular aortic repair of endoleaks : Diagnosis, treatment, and outcomes].

Authors:  Sven Rudolf Hauck; Rüdiger Schernthaner; Theresa-Marie Dachs; Maximilian Kern; Martin Funovics
Journal:  Radiologie (Heidelb)       Date:  2022-06-23

Review 2.  Secondary interventions following endovascular repair of abdominal aortic aneurysm.

Authors:  Naoki Toya; Yuji Kanaoka; Takao Ohki
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-10-22

3.  A Right Intercosto-Bronchial Artery Derived from the Thyrocervical Trunk: An Unusual Cause of Type II Endoleak Post Thoracic Aortic Stenting.

Authors:  Andrew Mtl Choong; Ken Mitchell; Jason Jenkins
Journal:  Korean J Thorac Cardiovasc Surg       Date:  2015-04-05

Review 4.  Endoluminal occlusion devices: technology update.

Authors:  Tobias Zander; Samantha Medina; Guillermo Montes; Lourdes Nuñez-Atahualpa; Michel Valdes; Manuel Maynar
Journal:  Med Devices (Auckl)       Date:  2014-12-01

Review 5.  Type II endoleaks: challenges and solutions.

Authors:  Andrew Brown; Greta K Saggu; Matthew J Bown; Robert D Sayers; David A Sidloff
Journal:  Vasc Health Risk Manag       Date:  2016-03-02

Review 6.  Secondary Endoleak Management Following TEVAR and EVAR.

Authors:  Seyed Ameli-Renani; Vyzantios Pavlidis; Robert A Morgan
Journal:  Cardiovasc Intervent Radiol       Date:  2020-08-10       Impact factor: 2.740

  6 in total