Literature DB >> 2339531

Evaluation of the polyethylene glycol antiglobulin test for detection of red blood cell antibodies.

A J de Man1, M A Overbeeke.   

Abstract

The polyethylene glycol (PEG) antiglobulin test (AGT) was evaluated by testing antibodies in the sera of 362 different patients and by screening of 4,685 random patient sera with both the PEG AGT and the albumin AGT. Agglutination in the PEG method was stronger in 254 (70.2%), identical in 99 (27.3%) and weaker in 9 (2.5%) of the 363 sera. Mean end-point titers of the antibodies measured with the PEG method (n = 137) were 2-3 dilutions higher than with the albumin method. In sera with anti-K and anti-Fyb antibodies the mean titer in the PEG method was only one dilution higher. Antibodies within the rhesus system were also tested with a two-stage enzyme test. Agglutination in the PEG method was stronger in 93 (50.3%), identical in 64 (34.6%) and weaker in 28 (15.1%) of the 185 sera. Mean antibody titers (n = 76) in the PEG method were 1-3 dilution steps higher for the various specificities than in the enzyme test. In 92 (2.0%) of the 4,685 sera screened in the PEG method, specific antibodies were detected; with the albumin method in 74 (1.6%) sera. The antibodies only detected with the PEG method had the specificities anti-D,-C,-Cw,-c,E,-K,-Jka and -M. Not detected by the PEG method were anti-Lea antibodies in one of the sera. It is concluded that the PEG AGT is a sensitive technique for the detection and identification of red cell antibodies and that it is superior to the albumin AGT.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2339531     DOI: 10.1111/j.1423-0410.1990.tb02092.x

Source DB:  PubMed          Journal:  Vox Sang        ISSN: 0042-9007            Impact factor:   2.144


  5 in total

1.  Factors affecting the antigen-antibody reaction.

Authors:  Roberto Reverberi; Lorenzo Reverberi
Journal:  Blood Transfus       Date:  2007-11       Impact factor: 3.443

2.  The statistical analysis of immunohaematological data.

Authors:  Roberto Reverberi
Journal:  Blood Transfus       Date:  2008-01       Impact factor: 3.443

3.  Increased detection of clinically significant antibodies and decreased incidence of delayed haemolytic transfusion reaction with the indirect antiglobulin test potentiated by polyethylene glycol compared to albumin: a Japanese study.

Authors:  Miho Okutsu; Hitoshi Ohto; Hiroyasu Yasuda; Kinuyo Kawabata; Satoshi Ono; Shunnichi Saito; Akiko Sugawara; Masami Kikuchi; Saori Miura; Youko Ishii; Kazuya Watanabe; Yuriko Tohyama; Kenneth E Nollet
Journal:  Blood Transfus       Date:  2010-11-26       Impact factor: 3.443

4.  Evaluation of a modified IAT-gel with polyethylenglycol (PEG) addition method for red blood cell antibody identification.

Authors:  L Gustafsson; A Wikman; J Lundahl
Journal:  J Clin Lab Anal       Date:  2004       Impact factor: 2.352

5.  Electrical properties of the red blood cell membrane and immunohematological investigation.

Authors:  Heloise Pöckel Fernandes; Carlos Lenz Cesar; Maria de Lourdes Barjas-Castro
Journal:  Rev Bras Hematol Hemoter       Date:  2011
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.