Literature DB >> 23392450

Late catch-up in lumen diameter at five-year angiography in MACE-free patients treated with sirolimus-eluting stents in the Primary Stenting of Totally Occluded Native Coronary Arteries: a randomised comparison of bare metal stent implantation with sirolimus-eluting stent implantation for the treatment of total coronary occlusions (PRISON II).

Koen Teeuwen1, Ben J L Van den Branden, Braim M Rahel, Gerrit J Laarman, Jan G P Tijssen, Johannes C Kelder, Ton Slagboom, Juriën M Ten Berg, Maarten J Suttorp.   

Abstract

AIMS: The present study was designed to examine the five-year angiographic follow-up of MACE-free patients enrolled in the PRISON II study. METHODS AND
RESULTS: In the PRISON II study a total of 200 patients were randomised to either bare metal stents (BMS) or sirolimus-eluting stents (SES) after successful recanalisation of total coronary occlusions (TCO). Patients free of MACE with available angiography at six months were approached for repeated angiography at five years. The primary endpoint was in-stent very late luminal loss (VLLL) at five years. The secondary endpoint was additional late luminal loss (ALLL) between six months and five years. At five years, repeated angiography was performed in 72 patients, 50/82 (61%) in the SES group and 22/58 (38%) in the BMS group. In-stent VLLL was lower in the SES group (0.19 mm ± 0.72 vs. 0.51 mm ± 0.71, p=0.09) compared to the BMS group and in-segment VLLL was comparable in both groups (0.01 mm±0.58 vs. 0.03 mm ± 0.73, p=0.89). Late catch-up in lumen diameter was observed in the SES group with a trend towards increased ALLL compared to the BMS group (in-stent, 0.35 mm ± 0.88 vs. 0.04 mm ± 0.81, p=0.16; in-segment, 0.20 mm ± 0.74 vs. -0.05 mm ± 0.73, p=0.19).
CONCLUSIONS: At five-year angiographic follow-up, late catch-up was observed after successful recanalisation of TCOs treated with SES. Despite a late catch-up, the angiographic results of SES were superior in-stent and similar in-segment compared to BMS.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23392450     DOI: 10.4244/EIJV9I2A36

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  2 in total

Review 1.  Choosing the right coronary stent in the modern era.

Authors:  Bora Toklu; Sripal Bangalore
Journal:  Curr Cardiol Rep       Date:  2014-04       Impact factor: 2.931

2.  Learning from the Cardiologists and Developing Eluting Stents Targeting the Mtor Pathway for Pulmonary Application; A Future Concept for Tracheal Stenosis.

Authors:  Paul Zarogoulidis; Kaid Darwiche; Kosmas Tsakiridis; Helmut Teschler; Lonny Yarmus; Konstantinos Zarogoulidis; Lutz Freitag
Journal:  J Mol Genet Med       Date:  2013-08-26
  2 in total