Literature DB >> 23392343

Registration of 3D+t coronary CTA and monoplane 2D+t X-ray angiography.

Coert T Metz1, Michiel Schaap, Stefan Klein, Nora Baka, Lisan A Neefjes, Carl J Schultz, Wiro J Niessen, Theo van Walsum.   

Abstract

A method for registering preoperative 3D+t coronary CTA with intraoperative monoplane 2D+t X-ray angiography images is proposed to improve image guidance during minimally invasive coronary interventions. The method uses a patient-specific dynamic coronary model, which is derived from the CTA scan by centerline extraction and motion estimation. The dynamic coronary model is registered with the 2D+t X-ray sequence, considering multiple X-ray time points concurrently, while taking breathing induced motion into account. Evaluation was performed on 26 datasets of 17 patients by comparing projected model centerlines with manually annotated centerlines in the X-ray images. The proposed 3D+t/2D+t registration method performed better than a 3D/2D registration method with respect to the accuracy and especially the robustness of the registration. Registration with a median error of 1.47 mm was achieved.

Entities:  

Mesh:

Year:  2013        PMID: 23392343     DOI: 10.1109/TMI.2013.2245421

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  4 in total

1.  A tree-topology preserving pairing for 3D/2D registration.

Authors:  Thomas Benseghir; Grégoire Malandain; Régis Vaillant
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-04-23       Impact factor: 2.924

2.  Registration of angiographic image on real-time fluoroscopic image for image-guided percutaneous coronary intervention.

Authors:  Dongkue Kim; Sangsoo Park; Myung Ho Jeong; Jeha Ryu
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-11-23       Impact factor: 2.924

3.  3D-2D registration in endovascular image-guided surgery: evaluation of state-of-the-art methods on cerebral angiograms.

Authors:  Uroš Mitrović; Boštjan Likar; Franjo Pernuš; Žiga Špiclin
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-10-24       Impact factor: 2.924

4.  3D multimodal cardiac data reconstruction using angiography and computerized tomographic angiography registration.

Authors:  Rohollah Moosavi Tayebi; Rahmita Wirza; Puteri S B Sulaiman; Mohd Zamrin Dimon; Fatimah Khalid; Aqeel Al-Surmi; Samaneh Mazaheri
Journal:  J Cardiothorac Surg       Date:  2015-04-22       Impact factor: 1.637

  4 in total