Novel device (AirWave) to assess endotracheal tube migration: a pilot study.

Gustavo Cumbo Nacheli1, Manish Sharma, Xiaofeng Wang, Amit Gupta, Jorge A Guzman, Adriano R Tonelli.   

Abstract

INTRODUCTION: Little is known about endotracheal tube (ETT) migration during routine care among critically ill patients. AirWave is a novel device that uses sonar waves to measure ETT migration and obstructions in real time. The aim of the present study is to assess the accuracy of the AirWave to evaluate ETT migration. In addition, we determined the degree of variation in ETT position and tested whether more pronounced migration occurs in specific clinical scenarios.
METHODS: After institutional review board approval, we included mechanically ventilated patients from February 2012 to May 2012. A chest radiography (CXR) was obtained at baseline and 24 hours when clinically indicated. The ETT distance at the lips was recorded at baseline and every 4 hours. The AirWave system continuously recorded ETT position changes from baseline, and luminal obstructions.
RESULTS: A total of 42 patients (age: 61 [SD ±13] years, men: 52%) were recruited. A total of 19 patients had measurements of ETT migration at 24 hours by the 3 methodologies used in this study. The mean (SD) of the ETT migration at 24 hours was +0.04 (1.2), -0.42 (0.7) and +0.34 (1.81) cm when measured by portable CXR, ETT distance at the teeth and AirWave device, respectively. Bland-Altman analysis of tube migration at 24 hours comparing the AirWave with CXR readings showed a bias of 0.1 cm with 95% limit of agreement of -3.8 and +4.3 cm. Comparison of tube migration at 24 hours determined by AirWave with ETT distance at the lips revealed a bias of -0.4 with 95% limit of agreement -3.7 to +3 cm, similar to the values observed between CXR and ETT distance at the lips (bias of -0.3 cm, 95% limit of agreement of -3.4 to +2.8 cm). Factors associated with ETT migration at 24 hours were ETT size and initial measurement from ETT tip to carina by portable CXR. AirWave detected in eight patients some degree of ETT obstruction (30% ± 9.6%) that resolved with prompt ETT catheter suction.
CONCLUSIONS: The AirWave may provide useful information regarding ETT migration and obstruction in real time.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  AirWave; Endotracheal tube; Migration; Obstruction

Mesh:

Year:  2013        PMID: 23391719      PMCID: PMC3713168          DOI: 10.1016/j.jcrc.2012.10.015

Source DB:  PubMed          Journal:  J Crit Care        ISSN: 0883-9441            Impact factor:   3.425


  27 in total

1.  The efficacy of esophageal detector devices in verifying tracheal tube placement: a randomized cross-over study of out-of-hospital cardiac arrest patients.

Authors:  K Tanigawa; T Takeda; E Goto; K Tanaka
Journal:  Anesth Analg       Date:  2001-02       Impact factor: 5.108

2.  A prospective multicenter trial testing the SCOTI device for confirmation of endotracheal tube placement.

Authors:  J Li
Journal:  J Emerg Med       Date:  2001-04       Impact factor: 1.484

3.  Impact of unplanned extubation and reintubation after weaning on nosocomial pneumonia risk in the intensive care unit: a prospective multicenter study.

Authors:  Arnaud de Lassence; Corinne Alberti; Elie Azoulay; Eric Le Miere; Christine Cheval; François Vincent; Yves Cohen; Maïté Garrouste-Orgeas; Christophe Adrie; Gilles Troche; Jean-François Timsit
Journal:  Anesthesiology       Date:  2002-07       Impact factor: 7.892

4.  Alteration of endotracheal tube position. Flexion and extension of the neck.

Authors:  P A Conrardy; L R Goodman; F Lainge; M M Singer
Journal:  Crit Care Med       Date:  1976 Jan-Feb       Impact factor: 7.598

5.  Secondary confirmation of endotracheal tube position by ultrasound image.

Authors:  Kai-Sheng Hsieh; Cheng-Liang Lee; Chu-Chung Lin; Ta-Cheng Huang; Ken-Pen Weng; Wen-Hsien Lu
Journal:  Crit Care Med       Date:  2004-09       Impact factor: 7.598

Review 6.  Verification of endotracheal tube position.

Authors:  M R Salem
Journal:  Anesthesiol Clin North Am       Date:  2001-12

7.  Comparison of three different methods to confirm tracheal tube placement in emergency intubation.

Authors:  Stefek Grmec
Journal:  Intensive Care Med       Date:  2002-04-30       Impact factor: 17.440

8.  Utility of daily routine portable chest radiographs in mechanically ventilated patients in the medical ICU.

Authors:  Mark Krivopal; Oksana A Shlobin; Richard M Schwartzstein
Journal:  Chest       Date:  2003-05       Impact factor: 9.410

Review 9.  Suctioning techniques for the removal of respiratory secretions.

Authors:  Tina Moore
Journal:  Nurs Stand       Date:  2003 Nov 12-18

10.  Utility of postintubation chest radiographs in the intensive care unit.

Authors:  R Lotano; D Gerber; C Aseron; R Santarelli; M Pratter
Journal:  Crit Care       Date:  2000-01-24       Impact factor: 9.097

View more
  1 in total

1.  Continuous monitoring of endotracheal tube positioning: closer to the sangreal?

Authors:  Ahmed El Kalioubie; Saad Nseir
Journal:  J Clin Monit Comput       Date:  2015-02       Impact factor: 2.502