Literature DB >> 23391635

Prevention of hemolysis in blood samples collected from intravenous catheters.

Giuseppe Lippi1, Paola Avanzini, Gianfranco Cervellin.   

Abstract

OBJECTIVES: Samples drawn through intravenous catheters are frequently hemolyzed. We planned a prospective, randomized study to establish whether hemolysis in samples drawn from intravenous catheters may be reduced using S-Monovette® tubes collected by manual aspiration as compared with standard vacuum tubes. DESIGN AND METHODS: We studied 52 consecutive patients admitted to the ED. Blood was drawn through a 20-gauge intravenous catheter. A 5.0mL, Becton Dickinson Vacutainer® SST II Plus serum tube was collected and discarded. In the odd group of patients (i.e., n. 1, 3, 5, etc.), a second SST II tube was drawn with vacuum ("BD-V"), followed by a 5.5mL S-Monovette® serum tube collected with manual aspiration ("SD-A") and an identical S-Monovette collected by vacuum ("SD-V"). In the pair group of patients (i.e., n. 2, 4, 6, etc.), the sequence was modified to "SD-A", "SD-V" and "BD-V". Serum was separated and tested for lactate dehydrogenase (LDH), potassium and cell-free hemoglobin.
RESULTS: The mean concentration of potassium (+2.7% in BD-V and +1.7% in SD-V, respectively), LDH (+15% in BD-V and +7% in SD-V, respectively) and cell-free hemoglobin was significantly increased when samples were collected with vacuum tubes as compared with manual aspiration. No significant differences were observed between SD-V and BD-V. The frequency of hemolyzed samples was higher when blood was collected with the vacuum as compared with SD-A (i.e., 2%), but did not differ between BD-V and SD-V (i.e., 29 versus 31%; p=0.70).
CONCLUSION: S-Monovette can be used with vacuum or aspiration collection. This latter approach allows blood drawing with limited shear stress and less likelihood of generating spuriously hemolysis.
Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23391635     DOI: 10.1016/j.clinbiochem.2013.01.021

Source DB:  PubMed          Journal:  Clin Biochem        ISSN: 0009-9120            Impact factor:   3.281


  10 in total

1.  The "EPiQ"-Study (Evaluation of preanalytical quality): S-Monovette® in manual aspiration mode drastically reduces hemolytic samples in head-to-head study.

Authors:  Laura Millius; Erwin Riedo; Thierry Caron; Juliette Belissent; Benoît Fellay; Vincent Ribordy; Jean-Luc Magnin
Journal:  Pract Lab Med       Date:  2021-07-28

2.  The use of S-Monovette is effective to reduce the burden of hemolysis in a large urban emergency department.

Authors:  Giuseppe Lippi; Patrizia Bonelli; Laura Bonfanti; Gianfranco Cervellin
Journal:  Biochem Med (Zagreb)       Date:  2015       Impact factor: 2.313

3.  Blood Samples of Peripheral Venous Catheter or The Usual Way: Do Infusion Fluid Alters the Biochemical Test Results?

Authors:  Mahboobeh Taghizadeganzadeh; Mohammadreza Yazdankhahfard; Mohammadreza Farzaneh; Kamran Mirzaei
Journal:  Glob J Health Sci       Date:  2015-11-03

4.  A review on laboratory tests' utilization: A trigger for cutting costs and quality improvement in health care settings.

Authors:  Zahra Meidani; Mehrdad Farzandipour; Alireza Farrokhian; Masomeh Haghighat
Journal:  Med J Islam Repub Iran       Date:  2016-05-08

5.  MicroRNA profiling of patient plasma for clinical trials using bioinformatics and biostatistical approaches.

Authors:  Joseph Markowitz; Zachary Abrams; Naduparambil K Jacob; Xiaoli Zhang; John N Hassani; Nicholas Latchana; Lai Wei; Kelly E Regan; Taylor R Brooks; Sarvani R Uppati; Kala M Levine; Tanios Bekaii-Saab; Kari L Kendra; Gregory B Lesinski; J Harrison Howard; Thomas Olencki; Philip R Payne; William E Carson
Journal:  Onco Targets Ther       Date:  2016-09-29       Impact factor: 4.147

6.  Effect of the PIVO Device on the Procedure of Phlebotomy from Peripheral IV Catheters.

Authors:  Suzanne Adams; Bridget Toroni; Meenal Lele
Journal:  Nurs Res Pract       Date:  2018-05-22

7.  Determination of Postprandial Glycemic Responses by Continuous Glucose Monitoring in a Real-World Setting.

Authors:  Martin Röhling; Tobias Martin; Meinolf Wonnemann; Martin Kragl; Horst Harald Klein; Lutz Heinemann; Stephan Martin; Kerstin Kempf
Journal:  Nutrients       Date:  2019-09-27       Impact factor: 5.717

8.  Intra-patient potassium variability after hypothermic cardiac arrest: a multicentre, prospective study.

Authors:  M Pasquier; M Blancher; S Buse; B Boussat; G Debaty; M Kirsch; M de Riedmatten; P Schoettker; T Annecke; P Bouzat
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2019-12-16       Impact factor: 2.953

9.  Reduction of gross hemolysis in catheter-drawn blood using Greiner Holdex tube holder.

Authors:  Giuseppe Lippi; Paola Avanzini; Rosalia Aloe; Gianfranco Cervellin
Journal:  Biochem Med (Zagreb)       Date:  2013       Impact factor: 2.313

Review 10.  Critical review and meta-analysis of spurious hemolysis in blood samples collected from intravenous catheters.

Authors:  Giuseppe Lippi; Gianfranco Cervellin; Camilla Mattiuzzi
Journal:  Biochem Med (Zagreb)       Date:  2013       Impact factor: 2.313

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.