Performance of infrared ear and forehead thermometers: a comparative study in 205 febrile and afebrile children.

Patricia A Hamilton1, Lorenzo S Marcos, Michelle Secic.   

Abstract

AIMS AND
OBJECTIVES: This study compared readings from two professional-grade, commercially available infrared (IR) thermometers, the ThermoScan® PRO 4000 prewarmed tip ear thermometer and the Temporal Scanner(™) TAT-5000 temporal artery thermometer.
BACKGROUND: The repeatability and precision of readings from IR thermometers for professional use were questioned in the past, but in recent years, these types of thermometers have been technologically improved, so their ability to replicate standard temperature readings reliably should be re-examined.
DESIGN: Febrile and afebrile children were recruited from the emergency department, overflow treatment areas and the paediatric intensive care unit of a large hospital in Argentina. Each child had a randomised sequence of seven temperature readings, including three from the ear, three from the forehead or behind the ear and one reference oral or rectal reading.
METHODS: Temperature readings were taken with the ThermoScan PRO 4000, the Temporal Scanner TAT-5000 and the monitor mode of SureTemp® Plus, a widely used professional-grade contact thermometer, for reference.
RESULTS: Of 205 children, 46% were febrile, per reference thermometer readings. While mean ThermoScan PRO 4000 febrile measurements did not differ significantly from reference, mean Temporal Scanner TAT-5000 febrile measurements were significantly lower (by a mean of 0·42 °C) than the reference. Overall bias of the ThermoScan PRO 4000 was significantly lower than that of the Temporal Scanner TAT-5000; repeatability was 1·5 times higher, and overall false-negative rate was about a third that of Temporal Scanner TAT-5000, when compared to the reference.
CONCLUSIONS: This study indicates that the ThermoScan PRO 4000 provides measurements closer to those of a professional-grade contact thermometer when compared to the Temporal Scanner TAT-5000. RELEVANCE TO CLINICAL PRACTICE: The odds of misclassifying a febrile child as non-febrile were about threefold higher with the Temporal Scanner TAT-5000 temporal artery thermometer than with the ThermoScan® PRO 4000 ear thermometer.
© 2013 Blackwell Publishing Ltd.

Entities:  

Keywords:  ear thermometer; fever; forehead thermometer; infrared thermometry; oral thermometer; temporal artery thermometer

Mesh:

Year:  2013        PMID: 23388031     DOI: 10.1111/jocn.12060

Source DB:  PubMed          Journal:  J Clin Nurs        ISSN: 0962-1067            Impact factor:   3.036


  6 in total

1.  Physiological responses between players with and without spinal cord injury in wheelchair basketball small-sided games.

Authors:  A Iturricastillo; J Yanci; A Los Arcos; C Granados
Journal:  Spinal Cord       Date:  2016-07-12       Impact factor: 2.772

2.  Effects of the off-Season Period on Field and Assistant Soccer Referees `Physical Performance.

Authors:  Daniel Castillo; Jesús Cámara; Carlo Castagna; Javier Yanci
Journal:  J Hum Kinet       Date:  2017-03-12       Impact factor: 2.193

Review 3.  The diagnostic accuracy of digital, infrared and mercury-in-glass thermometers in measuring body temperature: a systematic review and network meta-analysis.

Authors:  Valentina Pecoraro; Davide Petri; Giorgio Costantino; Alessandro Squizzato; Lorenzo Moja; Gianni Virgili; Ersilia Lucenteforte
Journal:  Intern Emerg Med       Date:  2020-11-25       Impact factor: 3.397

Review 4.  Temperature measurements with a temporal scanner: systematic review and meta-analysis.

Authors:  Håkan Geijer; Ruzan Udumyan; Georg Lohse; Ylva Nilsagård
Journal:  BMJ Open       Date:  2016-03-31       Impact factor: 2.692

5.  Forehead or ear temperature measurement cannot replace rectal measurements, except for screening purposes.

Authors:  Christian Backer Mogensen; Lena Wittenhoff; Gitte Fruerhøj; Stephen Hansen
Journal:  BMC Pediatr       Date:  2018-01-26       Impact factor: 2.125

6.  Diagnostic test accuracy of new generation tympanic thermometry in children under different cutoffs: a systematic review and meta-analysis.

Authors:  Dan Shi; Li-Yuan Zhang; Hai-Xia Li
Journal:  BMC Pediatr       Date:  2020-05-12       Impact factor: 2.125

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.