Literature DB >> 23387447

Orbital adherence with titanium mesh floor implants: a review of 10 cases.

Thomas L Kersey1, Stephen G J Ng, Paul Rosser, Brian Sloan, Richard Hart.   

Abstract

BACKGROUND: Multiple materials have been used in the repair of orbital floor fractures. We report 10 cases of complications relating to the use of titanium mesh orbital floor implants.
METHOD: A retrospective review of 10 cases in 2 centres in New Zealand. Patients presented with diplopia or eyelid retraction following repair of an orbital floor fracture with titanium mesh implants.
RESULTS: Ten patients (7 male, 3 female) aged between 15-78 years old (mean 39 years) presented with significant restriction of eye movement and/or eyelid retraction following repair of an orbital floor fracture with a titanium mesh implant. Seven patients presented with restriction of eye movement alone. Three patients had lower lid retraction in addition to restriction of eye movement. One patient presented with epiphora following erosion of the implant through the nasolacrimal duct. Seven patients underwent surgical removal of the implant with all patients showing improvement of extraocular movement post-operatively. Three cases did not undergo implant removal with one case showing mild improvement over 9 months, and 2 cases showing no improvement. The mean interval between the initial surgery and removal of the implant was 7.1 months. DISCUSSION: In our series, 7 cases required explantation of the original titanium implant. In these cases a vigorous fibrotic reaction had taken place between the orbital contents and the titanium mesh implant. We postulate that the fibrous reaction between the implant and the orbital contents caused the eye movement restriction and the lid retraction. Implant materials used in orbital floor fracture surgery should be inert with a flat profile rather than a mesh to prevent adhesions through the mesh that may cause cicatricial eye movement restriction and eyelid retraction.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23387447     DOI: 10.3109/01676830.2012.736597

Source DB:  PubMed          Journal:  Orbit        ISSN: 0167-6830


  6 in total

1.  Orbital Floor Reconstruction: A Comparison of Outcomes between Absorbable and Permanent Implant Systems.

Authors:  Marc A Polacco; Peter W Kahng; Chad K Sudoko; Benoit J Gosselin
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2018-06-05

2.  Orbital Adherence Syndrome following the Use of Titanium Precontoured Orbital Mesh for the Reconstruction of Posttraumatic Orbital Floor Defects.

Authors:  Geraldine Hwee Ping Lee; Samuel Yew Ming Ho
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2016-06-23

3.  Three-dimensional pre-bent titanium implant for concomitant orbital floor and medial wall fractures in an East asian population.

Authors:  Kyung Min Lee; Ji Ung Park; Sung Tack Kwon; Suk Wha Kim; Eui Cheol Jeong
Journal:  Arch Plast Surg       Date:  2014-09-15

4.  Orbital floor fractures--short- and intermediate-term complications depending on treatment procedures.

Authors:  Henrik Holtmann; Hatice Eren; Karoline Sander; Norbert R Kübler; Jörg Handschel
Journal:  Head Face Med       Date:  2016-01-05       Impact factor: 2.151

5.  Surgical Correction of Diplopia in Orbital Fracture: Influence of Material and Design.

Authors:  S M Balaji; Preetha Balaji
Journal:  Ann Maxillofac Surg       Date:  2019 Jan-Jun

6.  Orbital floor fractures: epidemiology and outcomes of 1594 reconstructions.

Authors:  Lukas Benedikt Seifert; Tim Mainka; Carlos Herrera-Vizcaino; Rene Verboket; Robert Sader
Journal:  Eur J Trauma Emerg Surg       Date:  2021-06-14       Impact factor: 3.693

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.