Machine perfusion viability testing.

Tim C van Smaalen1, E R Pieter Hoogland, L W Ernest van Heurn.   

Abstract

PURPOSE OF REVIEW: Pretransplant assessment of kidney graft viability may help clinicians to decide whether to accept or discard a kidney for transplantation. With the increasing demand for donor kidneys and the increased use of marginal kidneys, the need of viability markers has increased to pursue superior transplant outcomes. Hypothermic machine perfusion (HMP) provides the theoretical opportunity to assess the viability of donor kidneys. We discuss the novel developments in viability testing during HMP and address the future prospects. RECENT
FINDINGS: HMP viability testing has focused on the analysis of machine perfusion parameters and perfusate biomarkers. Renal resistance and the biomarkers lactate dehydrogenase, aspartate transaminase, glutathione-S-transferase, N-acetyl-β-D-glucosaminidase, heart-type fatty acid binding protein, lipid peroxidation products, redox-active iron and IL-18 are correlated with transplant outcome in terms of development of delayed graft function or graft survival. However, they all lack adequate predictive value for transplant outcome. New techniques including contrast-enhanced ultrasound, three-dimensional ultrasound and magnetic resonance spectrometry are promising methods to test kidney viability during HMP, but their value has to be established. The introduction of normothermic machine perfusion offers other promising opportunities for viability testing.
SUMMARY: Machine perfusion characteristics and perfusate biomarkers have been extensively studied. They often correlate with the transplant outcome, but the present viability tests are not reliable predictors of transplant outcome. New developments in kidney graft viability assessment are necessary to have a chance of being clinically useful in the future.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23385886     DOI: 10.1097/MOT.0b013e32835e2a1b

Source DB:  PubMed          Journal:  Curr Opin Organ Transplant        ISSN: 1087-2418            Impact factor:   2.640


  8 in total

Review 1.  The promise of organ and tissue preservation to transform medicine.

Authors:  Sebastian Giwa; Jedediah K Lewis; Luis Alvarez; Robert Langer; Alvin E Roth; George M Church; James F Markmann; David H Sachs; Anil Chandraker; Jason A Wertheim; Martine Rothblatt; Edward S Boyden; Elling Eidbo; W P Andrew Lee; Bohdan Pomahac; Gerald Brandacher; David M Weinstock; Gloria Elliott; David Nelson; Jason P Acker; Korkut Uygun; Boris Schmalz; Brad P Weegman; Alessandro Tocchio; Greg M Fahy; Kenneth B Storey; Boris Rubinsky; John Bischof; Janet A W Elliott; Teresa K Woodruff; G John Morris; Utkan Demirci; Kelvin G M Brockbank; Erik J Woods; Robert N Ben; John G Baust; Dayong Gao; Barry Fuller; Yoed Rabin; David C Kravitz; Michael J Taylor; Mehmet Toner
Journal:  Nat Biotechnol       Date:  2017-06-07       Impact factor: 54.908

2.  Glutathione S-transferase iso-enzymes in perfusate from pumped kidneys are associated with delayed graft function.

Authors:  I E Hall; R S Bhangoo; P P Reese; M D Doshi; F L Weng; K Hong; H Lin; G Han; R D Hasz; M J Goldstein; B Schröppel; C R Parikh
Journal:  Am J Transplant       Date:  2014-02-24       Impact factor: 8.086

3.  Associations of Perfusate Biomarkers and Pump Parameters With Delayed Graft Function and Deceased Donor Kidney Allograft Function.

Authors:  C R Parikh; I E Hall; R S Bhangoo; J Ficek; P L Abt; H Thiessen-Philbrook; H Lin; M Bimali; P T Murray; V Rao; B Schröppel; M D Doshi; F L Weng; P P Reese
Journal:  Am J Transplant       Date:  2016-02-17       Impact factor: 8.086

4.  Presence of Cytotoxic Extracellular Histones in Machine Perfusate of Donation After Circulatory Death Kidneys.

Authors:  Tim C van Smaalen; Daniëlle M H Beurskens; E R Pieter Hoogland; Bjorn Winkens; Maarten H L Christiaans; Chris P Reutelingsperger; L W Ernest van Heurn; Gerry A F Nicolaes
Journal:  Transplantation       Date:  2017-04       Impact factor: 4.939

5.  Predictive Score Model for Delayed Graft Function Based on Hypothermic Machine Perfusion Variables in Kidney Transplantation.

Authors:  Chen-Guang Ding; Yang Li; Xiao-Hui Tian; Xiao-Jun Hu; Pu-Xu Tian; Xiao-Ming Ding; He-Li Xiang; Jin Zheng; Wu-Jun Xue
Journal:  Chin Med J (Engl)       Date:  2018-11-20       Impact factor: 2.628

6.  Hypothermic Oxygenated Machine Perfusion of Liver Grafts from Brain-Dead Donors.

Authors:  Damiano Patrono; Astrid Surra; Giorgia Catalano; Giorgia Rizza; Paola Berchialla; Silvia Martini; Francesco Tandoi; Francesco Lupo; Stefano Mirabella; Chiara Stratta; Mauro Salizzoni; Renato Romagnoli
Journal:  Sci Rep       Date:  2019-06-27       Impact factor: 4.379

7.  Dynamic Parameters of Hypothermic Machine Perfusion-An Image of Initial Graft Function in Adult Kidney Transplantation?

Authors:  Sebastian Weberskirch; Shadi Katou; Stefan Reuter; Felicia Kneifel; Mehmet Haluk Morgul; Felix Becker; Philipp Houben; Andreas Pascher; Thomas Vogel; Sonia Radunz
Journal:  J Clin Med       Date:  2022-09-27       Impact factor: 4.964

8.  Rapid Identification of Ischemic Injury in Renal Tissue by Mass-Spectrometry Imaging.

Authors:  T C van Smaalen; S R Ellis; N E Mascini; T Porta Siegel; B Cillero-Pastor; L M Hillen; L W E van Heurn; C J Peutz-Kootstra; R M A Heeren
Journal:  Anal Chem       Date:  2019-02-15       Impact factor: 6.986

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.