Literature DB >> 23385283

Intraoperative ultrasound guidance during intracavitary brachytherapy applicator placement in cervical cancer: the University of Alabama at Birmingham experience.

Philip E Schaner1, Jimmy J Caudell, Jennifer F De Los Santos, Sharon A Spencer, Sui Shen, Robert Y Kim.   

Abstract

OBJECTIVE: The objective of this study was to evaluate the University of Alabama at Birmingham experience with routine intraoperative ultrasound (IUS)-guided tandem placement for cervical cancer.
METHODS: Between 1999 and 2008, 243 cervical cancer patients underwent IUS-guided tandem placement. One hundred thirty-nine patients received low-dose-rate brachytherapy, and 104 received high-dose-rate brachytherapy. Three hundred fifty-six IUS-guided procedures were performed. Clinical and imaging data were retrospectively analyzed to evaluate complications requiring reinsertion of tandem placement in the context of IUS.
RESULTS: All 243 cervical cancer patients completed intracavitary brachytherapy. Five (1.4%) of 356 IUS-guided applicator placements resulted in uterine perforation. All of these patients underwent successful tandem insertion on the second attempt, and no significant clinical sequelae occurred. Intraoperative ultrasound enabled direct uterine visualization and facilitated real-time feedback for selection of a suitable tandem length and curvature; no suboptimal placements requiring return to the operating room occurred (excluding perforation).
CONCLUSIONS: In this large series, IUS guidance substantially increased the rate of successful applicator placement and diminished the rate of uterine perforation relative to historical controls. We strongly recommend the use of IUS guidance during operative intrauterine tandem placement for cervical cancer.

Entities:  

Mesh:

Year:  2013        PMID: 23385283     DOI: 10.1097/IGC.0b013e3182859302

Source DB:  PubMed          Journal:  Int J Gynecol Cancer        ISSN: 1048-891X            Impact factor:   3.437


  6 in total

1.  Routine use of ultrasound guided tandem placement in intracavitary brachytherapy for the treatment of cervical cancer - a South Indian institutional experience.

Authors:  Pamidimukkala Bramhananda Rao; Saptarshi Ghosh
Journal:  J Contemp Brachytherapy       Date:  2015-10-19

Review 2.  Improving the efficiency of image guided brachytherapy in cervical cancer.

Authors:  Sophie Otter; Adrian Franklin; Mazhar Ajaz; Alexandra Stewart
Journal:  J Contemp Brachytherapy       Date:  2016-12-06

3.  Clinical and dosimetric consequences of imperfect applicator insertion in cervical cancer brachytherapy.

Authors:  Bikramjit Chakrabarti; Suparna Kanti Pal; Harris Mahammad Sepai; Somapriya Basu Roy; Sanjay Kr Kar; Annesha Lahiri; Sounik Das; Amit Bala
Journal:  J Contemp Brachytherapy       Date:  2018-08-31

Review 4.  The use of intra-operative ultrasound in gynecological surgery: a review.

Authors:  Karen Grewal; Benjamin Jones; Ariadne L'Heveder; Sita Jindal; Nicolas Galazis; Srdjan Saso; Joseph Yazbek
Journal:  Future Sci OA       Date:  2021-01-12

5.  Prevention of uterine perforation during intracavitary brachytherapy of cervical cancer.

Authors:  Mehmet Bayrak; Candan D Abakay
Journal:  J Contemp Brachytherapy       Date:  2021-04-14

6.  Incidence of Suboptimal Applicator Placement and the Resulting Dosimetric Impact in Image-Based Intracavitary Brachytherapy.

Authors:  Ramya Rangarajan
Journal:  J Med Phys       Date:  2018 Jul-Sep
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.