The SADRA Lotus Valve System: a fully repositionable, retrievable prosthesis.

R Gooley1, S Lockwood, P Antonis, I T Meredith.   

Abstract

Transcatheter aortic valve implantation (TAVI) has become the preferred treatment option for patients with severe aortic stenosis at extreme surgical risk and an acceptable alternative to surgical aortic valve replacement in patients at high risk. Despite a growing amount of evidence in support of TAVI there remain important limitations and recognized complications. The SADRA Lotus Valve System is a novel TAVI device capable of allowing full repositionability and retrievability, which may address some of the first generation limitations.

Entities:  

Mesh:

Year:  2013        PMID: 23381379

Source DB:  PubMed          Journal:  Minerva Cardioangiol        ISSN: 0026-4725            Impact factor:   1.347


  4 in total

1.  Late expansion of mechanically expanding transcatheter aortic valves.

Authors:  Yusuke Kobari; Taku Inohara; Shohei Imaeda; Sosuke Myojin; Toshinobu Ryuzaki; Tetsuya Saito; Nobuhiro Yoshijima; Makoto Tanaka; Hikaru Tsuruta; Fumiaki Yashima; Hideyuki Shimizu; Keiichi Fukuda; Kentaro Hayashida
Journal:  Cardiovasc Interv Ther       Date:  2022-02-07

Review 2.  Clinical implications of conduction abnormalities and arrhythmias after transcatheter aortic valve implantation.

Authors:  Robert M A van der Boon; Patrick Houthuizen; Rutger-Jan Nuis; Nicolas M van Mieghem; Frits Prinzen; Peter P T de Jaegere
Journal:  Curr Cardiol Rep       Date:  2014-01       Impact factor: 2.931

3.  Clinical outcomes of the Lotus Valve in patients with bicuspid aortic valve stenosis: An analysis from the RESPOND study.

Authors:  Daniel J Blackman; Lennart Van Gils; Sabine Bleiziffer; Ulrich Gerckens; Anna Sonia Petronio; Mohamed Abdel-Wahab; Nikos Werner; Saib S Khogali; Peter Wenaweser; Jochen Wöhrle; Osama Soliman; Jean-Claude Laborde; Dominic J Allocco; Ian T Meredith; Volkmar Falk; Nicolas M Van Mieghem
Journal:  Catheter Cardiovasc Interv       Date:  2019-02-17       Impact factor: 2.692

4.  Transcatheter aortic valve implantation in patients with bicuspid aortic valve stenosis utilizing the next-generation fully retrievable and repositionable valve system: mid-term results from a prospective multicentre registry.

Authors:  Janusz Kochman; Karol Zbroński; Łukasz Kołtowski; Radosław Parma; Andrzej Ochała; Zenon Huczek; Bartosz Rymuza; Radosław Wilimski; Maciej Dąbrowski; Adam Witkowski; Piotr Scisło; Marek Grygier; Maciej Lesiak; Grzegorz Opolski
Journal:  Clin Res Cardiol       Date:  2019-09-02       Impact factor: 5.460