Literature DB >> 23380409

Comparison of posterior corneal imaging before and after LASIK using dual rotating scheimpflug and scanning slit-beam corneal tomography systems.

Mary Ellen Sy1, Arturo Ramirez-Miranda, Siamak Zarei-Ghanavati, Jamison Engle, Jennifer Danesh, D Rex Hamilton.   

Abstract

PURPOSE: To compare the maximum posterior elevation (MPE) measurements before and after LASIK using a dual rotating Scheimpflug (DRS) imaging system (Galilei, Ziemer Ophthalmic Systems, Port, Switzerland) and a scanning slit-beam (SSB) imaging system (Orbscan IIz, Bausch & Lomb, Rochester, NY).
METHODS: This retrospective study included 78 eyes from 78 patients who underwent myopic LASIK. Preoperative and postoperative data collected included anterior and posterior best-fit sphere radius and axial curvature readings, posterior central elevation (PCE), and MPE relative to a best-fit sphere using a 7.8-mm region of interest. Data were compared using paired t test analysis.
RESULTS: Mean preoperative PCE (5.06 ± 2.29 μm with the DRS system and 12.78 ± 6.90 μm with the SSB system) and MPE (4.87 ± 4 μm with the DRS system and 15.44 ± 9.78 μm with the SSB system) were statistically different (P < .001). Mean postoperative PCE (4.55 ± 2.34 μm with the DRS system and 20.59 ± 8.11 μm with the SSB system) and MPE (4.90 ± 3.35 μm with the DRS system and 24.95 ± 10.15 μm with the SSB system) were statistically different (P < .001). The difference between preoperative and postoperative MPE measurements by DRS was not statistically significant (P = .953), whereas the difference measured by SSB was statistically significant (P < .001).
CONCLUSIONS: The consistency of DRS measurements suggests that the posterior surface of the cornea does not change appreciably after keratorefractive surgery and is imaged more accurately using DRS compared with SSB. The DRS system affords confidence in interpreting data that are useful for discerning morphologic abnormalities of the cornea, both before and after keratorefractive surgery. Copyright 2013, SLACK Incorporated.

Entities:  

Mesh:

Year:  2013        PMID: 23380409     DOI: 10.3928/1081597X-20130117-03

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  3 in total

1.  Five-year stability of posterior corneal surface after small incision lenticule extraction for high myopia.

Authors:  Yu Zhao; Xue Lin; Zhuoyi Chen; Xingtao Zhou
Journal:  BMC Ophthalmol       Date:  2022-05-28       Impact factor: 2.086

2.  Two-year observation of posterior corneal elevations after small incision lenticule extraction (SMILE) for myopia higher than -10 dioptres.

Authors:  Xueyi Zhou; Jianmin Shang; Bing Qin; Yu Zhao; Xingtao Zhou
Journal:  Br J Ophthalmol       Date:  2019-04-29       Impact factor: 4.638

3.  Three-Year Follow-Up of Posterior Corneal Elevation in Thin Corneas After Small Incision Lenticule Extraction.

Authors:  Yu Zhao; Dan Fu; Zhuoyi Chen; Xingtao Zhou
Journal:  Front Med (Lausanne)       Date:  2022-02-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.