Laboratory assessment of novel oral anticoagulants: method suitability and variability between coagulation laboratories.

Tuukka A Helin1, Anja Pakkanen, Riitta Lassila, Lotta Joutsi-Korhonen.   

Abstract

BACKGROUND: Laboratory tests to assess novel oral anticoagulants (NOACs) are under evaluation. Routine monitoring is unnecessary, but under special circumstances bioactivity assessment becomes crucial. We analyzed the effects of NOACs on coagulation tests and the availability of specific assays at different laboratories.
METHODS: Plasma samples spiked with dabigatran (Dabi; 120 and 300 μg/L) or rivaroxaban (Riva; 60, 146, and 305 μg/L) were sent to 115 and 38 European laboratories, respectively. International normalized ratio (INR) and activated partial thromboplastin time (APTT) were analyzed for all samples; thrombin time (TT) was analyzed specifically for Dabi and calibrated anti-activated factor X (anti-Xa) activity for Riva. We compared the results with patient samples.
RESULTS: Results of Dabi samples were reported by 73 laboratories (13 INR and 9 APTT reagents) and Riva samples by 22 laboratories (5 INR and 4 APTT reagents). Both NOACs increased INR values; the increase was modest, albeit larger, for Dabi, with higher CV, especially with Quick (vs Owren) methods. Both NOACs dose-dependently prolonged the APTT. Again, the prolongation and CVs were larger for Dabi. The INR and APTT results varied reagent-dependently (P < 0.005), with less prolongation in patient samples. TT results (Dabi) and calibrated anti-Xa results (Riva) were reported by only 11 and 8 laboratories, respectively.
CONCLUSIONS: The screening tests INR and APTT are suboptimal in assessing NOACs, having high reagent dependence and low sensitivity and specificity. They may provide information, if laboratories recognize their limitations. The variation will likely increase and the sensitivity differ in clinical samples. Specific assays measure NOACs accurately; however, few laboratories applied them.
© 2013 American Association for Clinical Chemistry.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23378569     DOI: 10.1373/clinchem.2012.198788

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  27 in total

Review 1.  Laboratory Assessment of the Anticoagulant Activity of Direct Oral Anticoagulants: A Systematic Review.

Authors:  Bethany T Samuelson; Adam Cuker; Deborah M Siegal; Mark Crowther; David A Garcia
Journal:  Chest       Date:  2016-09-13       Impact factor: 9.410

Review 2.  Non-Vitamin K Antagonist Oral Anticoagulant Use in Patients With Atrial Fibrillation and Associated Intracranial Hemorrhage: A Focused Review.

Authors:  Boris Arbit; Jonathan C Hsu
Journal:  Clin Cardiol       Date:  2015-07-14       Impact factor: 2.882

3.  Effects of thromboprophylactic doses of apixaban and rivaroxaban on coagulation and thrombin generation in association with total hip replacement.

Authors:  Tuukka A Helin; Lauri Virtanen; Mikko Manninen; Jarkko Leskinen; Juhana Leppilahti; Lotta Joutsi-Korhonen; Riitta Lassila
Journal:  J Thromb Thrombolysis       Date:  2017-05       Impact factor: 2.300

4.  Laboratory tests during direct oral anticoagulant treatment? No.

Authors:  Giovanni Di Minno; Elena Ricciardi; Antonella Scalera
Journal:  Intern Emerg Med       Date:  2013-05-21       Impact factor: 3.397

5.  Perioperative management of patients who are receiving a novel oral anticoagulant.

Authors:  Aaron Liew; James Douketis
Journal:  Intern Emerg Med       Date:  2013-06-27       Impact factor: 3.397

Review 6.  Direct oral anticoagulant considerations in solid organ transplantation: A review.

Authors:  David M Salerno; Demetra Tsapepas; Apostolos Papachristos; Jae-Hyung Chang; Spencer Martin; Mark A Hardy; Jaclyn McKeen
Journal:  Clin Transplant       Date:  2016-12-28       Impact factor: 2.863

7.  A case of rivaroxaban associated spontaneous hemothorax.

Authors:  İbrahim Yıldız; Ebubekir Aksu; Pınar Özmen Özmen Yıldız; İsmail Gürbak
Journal:  Turk Gogus Kalp Damar Cerrahisi Derg       Date:  2019-01-01       Impact factor: 0.332

Review 8.  Laboratory measurement of the non-vitamin K antagonist oral anticoagulants: selecting the optimal assay based on drug, assay availability, and clinical indication.

Authors:  Adam Cuker
Journal:  J Thromb Thrombolysis       Date:  2016-02       Impact factor: 2.300

Review 9.  Measurement and reversal of the direct oral anticoagulants.

Authors:  Bethany T Samuelson; Adam Cuker
Journal:  Blood Rev       Date:  2016-09-02       Impact factor: 8.250

10.  Relationship between plasma dabigatran concentration and activated partial thromboplastin time in Japanese patients with non-valvular atrial fibrillation.

Authors:  Daiki Shimomura; Yoshihisa Nakagawa; Hirokazu Kondo; Toshihiro Tamura; Masashi Amano; Yukiko Hayama; Naoaki Onishi; Yodo Tamaki; Makoto Miyake; Kazuaki Kaitani; Chisato Izumi; Masahiko Hayashida; Aya Fukuda; Fumihiko Nakamura; Seiji Kawano
Journal:  J Arrhythm       Date:  2014-12-18
View more