Literature DB >> 23377533

WHOLE BODY NONRIGID CT-PET REGISTRATION USING WEIGHTED DEMONS.

J W Suh1, Oh-K Kwon, D Scheinost, A J Sinusas, Gary W Cline, X Papademetris.   

Abstract

We present a new registration method for whole-body rat computed tomography (CT) image and positron emission tomography (PET) images using a weighted demons algorithm. The CT and PET images are acquired in separate scanners at different times and the inherent differences in the imaging protocols produced significant nonrigid changes between the two acquisitions in addition to heterogeneous image characteristics. In this situation, we utilized both the transmission-PET and the emission-PET images in the deformable registration process emphasizing particular regions of the moving transmission-PET image using the emission-PET image. We validated our results with nine rat image sets using M-Hausdorff distance similarity measure. We demonstrate improved performance compared to standard methods such as Demons and normalized mutual information-based non-rigid FFD registration.

Entities:  

Year:  2011        PMID: 23377533      PMCID: PMC3557845          DOI: 10.1109/isbi.2011.5872622

Source DB:  PubMed          Journal:  Proc IEEE Int Symp Biomed Imaging        ISSN: 1945-7928


  6 in total

1.  Nonrigid registration using free-form deformations: application to breast MR images.

Authors:  D Rueckert; L I Sonoda; C Hayes; D L Hill; M O Leach; D J Hawkes
Journal:  IEEE Trans Med Imaging       Date:  1999-08       Impact factor: 10.048

2.  Comparison of mutual information-based warping accuracy for fusing body CT and PET by 2 methods: CT mapped onto PET emission scan versus CT mapped onto PET transmission scan.

Authors:  Joseph Skalski; Richard L Wahl; Charles R Meyer
Journal:  J Nucl Med       Date:  2002-09       Impact factor: 10.057

3.  Automated 3-dimensional elastic registration of whole-body PET and CT from separate or combined scanners.

Authors:  Raj Shekhar; Vivek Walimbe; Shanker Raja; Vladimir Zagrodsky; Mangesh Kanvinde; Guiyun Wu; Bohdan Bybel
Journal:  J Nucl Med       Date:  2005-09       Impact factor: 10.057

4.  A three-dimensional registration method for automated fusion of micro PET-CT-SPECT whole-body images.

Authors:  Meei-Ling Jan; Keh-Shih Chuang; Guo-Wei Chen; Yu-Ching Ni; Sharon Chen; Chih-Hsien Chang; Jay Wu; Te-Wei Lee; Ying-Kai Fu
Journal:  IEEE Trans Med Imaging       Date:  2005-07       Impact factor: 10.048

5.  Object matching algorithms using robust Hausdorff distance measures.

Authors:  D G Sim; O K Kwon; R H Park
Journal:  IEEE Trans Image Process       Date:  1999       Impact factor: 10.856

6.  Multimodality image registration by maximization of mutual information.

Authors:  F Maes; A Collignon; D Vandermeulen; G Marchal; P Suetens
Journal:  IEEE Trans Med Imaging       Date:  1997-04       Impact factor: 10.048

  6 in total
  1 in total

1.  Experimental Evaluation of a Deformable Registration Algorithm for Motion Correction in PET-CT Guided Biopsy.

Authors:  Rahul Khare; Guillaume Sala; Paul Kinahan; Giuseppe Esposito; Filip Banovac; Kevin Cleary; Andinet Enquobahrie
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2013 Oct-Nov
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.