Literature DB >> 23374550

Mucinous carcinomas of the breast: imaging features and potential for misdiagnosis.

Judith Zhi-Yie Tan1, John Waugh, Beena Kumar, Jill Evans.   

Abstract

INTRODUCTION: Pure mucinous breast carcinomas (PMBC) are commonly lobulated, therefore appear relatively benign compared with the imaging features of invasive ductal carcinoma. The aim of this study was to determine mammographic and sonographic patterns of PMBC, in particular features that may result in misdiagnosis.
METHODS: Retrospective review of available mammography and sonography in 90 patients diagnosed with PMBC within the Monash BreastScreen service, 1993-2011 inclusive.
RESULTS: PMBC commonly have indistinct or lobulated mammographic and sonographic margins. Mammographic calcifications are absent in the majority (82%). On ultrasound, these neoplasms are commonly isoechoic (51%) with normal posterior acoustic appearances (80%). However, most (77%) of these lesions have suspicious or definite imaging features of malignancy.
CONCLUSION: PMBC are commonly lobulated with homogeneous, isoechoic and normal posterior acoustic sonographic appearances but rarely have benign imaging features.
© 2012 The Authors. Journal of Medical Imaging and Radiation Oncology © 2012 The Royal Australian and New Zealand College of Radiologists.

Entities:  

Mesh:

Year:  2012        PMID: 23374550     DOI: 10.1111/1754-9485.12006

Source DB:  PubMed          Journal:  J Med Imaging Radiat Oncol        ISSN: 1754-9477            Impact factor:   1.735


  7 in total

1.  Clinicopathological Characteristics of Mucinous Breast Cancer: A Retrospective Analysis of a 10-Year Study.

Authors:  Lei Lei; Xingfei Yu; Bo Chen; Zhanhong Chen; Xiaojia Wang
Journal:  PLoS One       Date:  2016-05-27       Impact factor: 3.240

2.  Histopathological analysis of mucinous breast cancer subtypes and comparison with invasive carcinoma of no special type.

Authors:  Michał Piotr Budzik; Marta Magdalena Fudalej; Anna Maria Badowska-Kozakiewicz
Journal:  Sci Rep       Date:  2021-03-11       Impact factor: 4.379

3.  Diagnostic value of artificial intelligence automatic detection systems for breast BI-RADS 4 nodules.

Authors:  Shu-Yi Lyu; Yan Zhang; Mei-Wu Zhang; Bai-Song Zhang; Li-Bo Gao; Lang-Tao Bai; Jue Wang
Journal:  World J Clin Cases       Date:  2022-01-14       Impact factor: 1.337

4.  Mucinous carcinoma of the breast: Diagnosis and management of an unusually young patient.

Authors:  Denny Marcela Achicanoy Puchana; Fabricio Andres Lasso Andrade; Diana Fernanda Achicanoy Puchana; María Alejandra Boada Fuentes; María Alejandra Álvarez Duarte; Karolayn Angarita Acuña; Andrea Carolina Jaime Aguirre; Jessica Alejandra Muñoz Murillo; Amanda Mercedes González Lago; Daniel Andres Alegria Cuellar; Luisa Katherine Orozco Morales; Migdalia Zamirna Zuleny Lasso Anacona; Alex Efren Alvarado Rengifo; Jose Rafael Rosero Rosero
Journal:  Radiol Case Rep       Date:  2022-03-02

5.  Pure mucinous carcinoma of the breast: clinicopathologic characteristics and long-term outcome among Taiwanese women.

Authors:  Hsin-Shun Tseng; Che Lin; Szu-Erh Chan; Su-Yu Chien; Shou-Jen Kuo; Shou-Tung Chen; Tsai-Wang Chang; Dar-Ren Chen
Journal:  World J Surg Oncol       Date:  2013-06-14       Impact factor: 2.754

6.  Mucinous breast cancer - clinical characteristics and treatment results in patients treated at the Oncology Centre in Kraków between 1952 and 2002.

Authors:  Beata Sas-Korczyńska; Jerzy Mituś; Andrzej Stelmach; Janusz Ryś; Anna Majczyk
Journal:  Contemp Oncol (Pozn)       Date:  2014-06-03

7.  Aggressive behavior of Her-2 positive colloid breast carcinoma: A case report in a metastatic breast cancer.

Authors:  Sumadi Lukman Anwar; Ery Kus Dwianingsih; Widya Surya Avanti; Lina Choridah; Teguh Aryandono
Journal:  Ann Med Surg (Lond)       Date:  2020-03-10
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.