OBJECTIVE: To (1) determine the temperature change in equine tendon and muscle during therapeutic ultrasound and (2) develop guidelines for treating horses for muscular or tendinous injury using therapeutic ultrasound. STUDY DESIGN: Experimental, in vivo study. ANIMALS: Adult horses (n = 10). METHODS: Thermistors were inserted in the superficial and deep digital flexor tendons (SDFT and DDFT) of the thoracic limbs of 10 adult horses. On the left, 3.3 MHz therapeutic continuous ultrasound was done for 10 minutes at an intensity of 1.0 W/cm(2) and for the right thoracic limb at 1.5 W/cm(2). Thermistors were placed at 1 cm, 4 cm, and 8 cm depths in the epaxial muscles of the same 10 horses, for a 20-minute treatment at a frequency of 3.3 MHz and intensity of 1.5 W/cm(2). Temperature was recorded before, during, and after treatment. Data were statistically analyzed. RESULTS: Mean temperature rise was 3.5°C in the SDFT and 2.5°C in the DDFT at the end of the 1.0 W/cm(2) treatment (P = .94) and 5.2°C in the SDFT and 3.0°C in the DDFT at the end of the 1.5-W/cm(2) treatment (P = .48). Mean temperature rise in epaxial musculature was 1.3°C at a depth of 1.0 cm, 0.7°C at 4.0 cm, and 0.7°C at 8 cm. CONCLUSIONS: The SDFT and DDFT are heated to a therapeutic temperature using a frequency of 3.3 MHz and intensity of 1.0 W/cm(2). The epaxial muscles are not heated to a therapeutic temperature using a frequency of 3.3 MHz and an intensity of 1.5 W/cm(2). © Copyright 2013 by The American College of Veterinary Surgeons.
OBJECTIVE: To (1) determine the temperature change in equine tendon and muscle during therapeutic ultrasound and (2) develop guidelines for treating horses for muscular or tendinous injury using therapeutic ultrasound. STUDY DESIGN: Experimental, in vivo study. ANIMALS: Adult horses (n = 10). METHODS: Thermistors were inserted in the superficial and deep digital flexor tendons (SDFT and DDFT) of the thoracic limbs of 10 adult horses . On the left, 3.3 MHz therapeutic continuous ultrasound was done for 10 minutes at an intensity of 1.0 W/cm(2) and for the right thoracic limb at 1.5 W/cm(2). Thermistors were placed at 1 cm, 4 cm, and 8 cm depths in the epaxial muscles of the same 10 horses , for a 20-minute treatment at a frequency of 3.3 MHz and intensity of 1.5 W/cm(2). Temperature was recorded before, during, and after treatment. Data were statistically analyzed. RESULTS: Mean temperature rise was 3.5°C in the SDFT and 2.5°C in the DDFT at the end of the 1.0 W/cm(2) treatment (P = .94) and 5.2°C in the SDFT and 3.0°C in the DDFT at the end of the 1.5-W/cm(2) treatment (P = .48). Mean temperature rise in epaxial musculature was 1.3°C at a depth of 1.0 cm, 0.7°C at 4.0 cm, and 0.7°C at 8 cm. CONCLUSIONS: The SDFT and DDFT are heated to a therapeutic temperature using a frequency of 3.3 MHz and intensity of 1.0 W/cm(2). The epaxial muscles are not heated to a therapeutic temperature using a frequency of 3.3 MHz and an intensity of 1.5 W/cm(2). © Copyright 2013 by The American College of Veterinary Surgeons.
Entities: Disease
Species
Mesh: See more »
Year: 2013
PMID: 23373839 DOI: 10.1111/j.1532-950X.2013.01099.x
Source DB: PubMed Journal: Vet Surg ISSN: 0161-3499 Impact factor: 1.495