Literature DB >> 23370731

Application of the pencil-beam redefinition algorithm in heterogeneous media for proton beam therapy.

Y Egashira1, T Nishio, K Hotta, R Kohno, M Uesaka.   

Abstract

In proton beam therapy, changes in the proton range due to lateral heterogeneity may cause serious errors in the dose distribution. In the present study, the pencilbeam redefinition algorithm (PBRA) was applied to proton beam therapy to address the problem of lateral density heterogeneity. In the calculation, the phase-space parameters were characterized for multiple range (i.e. proton energy) bins for given pencil beams. The particles that were included in each pencil beam were transported and redefined periodically until they had stopped. The redefined beams formed a detouring path that was different from that of the non-redefined pencil beams, and the path of each redefined beam was straight. The results calculated by the PBRA were compared with measured proton dose distributions in a heterogeneous slab phantom and an anthropomorphic phantom. Through the beam redefinition process, the PBRA was able to predict the measured proton-detouring effects. Therefore, the PBRA may allow improved calculation accuracy when dealing with lateral heterogeneities in proton therapy applications.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23370731     DOI: 10.1088/0031-9155/58/4/1169

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Site-specific range uncertainties caused by dose calculation algorithms for proton therapy.

Authors:  J Schuemann; S Dowdell; C Grassberger; C H Min; H Paganetti
Journal:  Phys Med Biol       Date:  2014-07-03       Impact factor: 3.609

2.  Quantification of proton dose calculation accuracy in the lung.

Authors:  Clemens Grassberger; Juliane Daartz; Stephen Dowdell; Thomas Ruggieri; Greg Sharp; Harald Paganetti
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-04-11       Impact factor: 7.038

3.  Proton range verification in inhomogeneous tissue: Treatment planning system vs. measurement vs. Monte Carlo simulation.

Authors:  Dae-Hyun Kim; Sungkoo Cho; Kwanghyun Jo; EunHyuk Shin; Chae-Seon Hong; Youngyih Han; Tae-Suk Suh; Do Hoon Lim; Doo Ho Choi
Journal:  PLoS One       Date:  2018-03-05       Impact factor: 3.240