Literature DB >> 23369751

Reliability and validity of goniometric and photographic measurements of clavicular tilt angle.

Sung-min Ha1, Oh-yun Kwon, Jong-hyuck Weon, Moon-hwan Kim, Su-jung Kim.   

Abstract

The aims of the present study were to assess the reliability of clavicular tilt angle measurement using goniometric and photographic measurements and to test the validity of the measurement by comparing the results with radiographic findings (gold standard). Clavicular tilt angles were measured in 18 healthy subjects (36 clavicles) using goniometric, photographic, and radiographic measurement. Repeated measurements using goniometric and photographic measurements were made in two test sessions conducted on different days by two examiners to assess inter-rater and intra-rater reliability of the two methods. Radiographic measurement was taken once, and the correlation between the radiographic findings and those of the indirect methods was calculated to test the validity of the goniometric and photographic measurement of clavicular tilt angle. No significant difference in clavicular tilt angle measurement was found between test sessions. The reliability of goniometric measurement (inter-rater intraclass correlation coefficients (ICC) = 0.85 (95% CI = 0.72-0.92) - 0.87 (95% CI = 0.77-0.87); intra-rater ICC = 0.80 (95% CI = 0.64-0.89)) and photographic measurement (inter-rater ICC = 0.89 (95% CI = 0.80-0.94) - 0.95 (95% CI = 0.91-0.98); intra-rater ICC = 0.84 (95% CI = 0.71-0.92) - 0.84 (95% CI = 0.69-0.91)) were excellent. The goniometric and photographic measurements of clavicular tilt angle were highly correlated with the radiographic findings (r = 0.83, 0.78, respectively). Goniometric and photographic measurements of clavicular tilt angle obtained by raters in this study may be considered reliable, and data obtained using the goniometric and photographic measurements are representative of radiographic findings of clavicular tilt angle.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Keywords:  Clavicular tilt angle; Postural alignment; Shoulder girdle

Mesh:

Year:  2013        PMID: 23369751     DOI: 10.1016/j.math.2012.12.006

Source DB:  PubMed          Journal:  Man Ther        ISSN: 1356-689X


  1 in total

1.  Reliability and validity of angle measurements using radiograph and smartphone applications: experimental research on protractor.

Authors:  Takenori Awatani; Taisuke Enoki; Ikuhiro Morikita
Journal:  J Phys Ther Sci       Date:  2017-10-21