Literature DB >> 23369553

Heparin-bonded, expanded polytetrafluoroethylene-lined stent graft in the treatment of femoropopliteal artery disease: 1-year results of the VIPER (Viabahn Endoprosthesis with Heparin Bioactive Surface in the Treatment of Superficial Femoral Artery Obstructive Disease) trial.

Richard R Saxon1, Arun Chervu, Paul A Jones, Tanvir K Bajwa, Dennis R Gable, Peter A Soukas, Richard J Begg, John G Adams, Gary M Ansel, Darren B Schneider, Charles M Eichler, Michael J Rush.   

Abstract

PURPOSE: To evaluate the performance of a heparin-bonded, expanded polytetrafluoroethylene (ePTFE)-lined nitinol endoprosthesis in the treatment of long-segment occlusive disease of the femoropopliteal artery (FPA) and to identify factors associated with loss of patency.
MATERIALS AND METHODS: In a single-arm, prospective, 11-center study (VIPER [Gore Viabahn Endoprosthesis with Heparin Bioactive Surface in the Treatment of Superficial Femoral Artery Obstructive Disease] trial), 119 limbs (113 patients; 69 men; mean age, 67 y), including 88 with Rutherford category 3-5 disease and 72 with Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II) C or D lesions of the FPA, underwent stent graft implantation. The mean lesion length was 19 cm; 56% of lesions were occlusions. Follow-up evaluations included color duplex ultrasonography in all patients, with patency defined as a peak systolic velocity ratio< 2.5.
RESULTS: At 12 months, Rutherford category and ankle-brachial index (ABI) were significantly improved (mean category improvement, 2.4; ABI increased from 0.6±0.2 to 0.9±0.19; P<.0001). Primary and secondary patency rates were 73% and 92%. The primary patency for devices oversized<20% at the proximal landing zone was 88%, whereas the primary patency for devices oversized by>20% was 70% (P = .047). Primary patency was not significantly affected by device diameter (5 vs 6 vs 7 mm) or lesion length (≤20 cm vs>20 cm). The 30-day major adverse event rate was 0.8%.
CONCLUSIONS: The heparin-bonded, ePTFE/nitinol stent graft provided clinical improvement and a primary patency rate of 73% at 1 year in the treatment of long-segment FPA disease. Careful sizing of the device relative to vessel landing zones is essential for achieving optimal outcomes.
Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23369553     DOI: 10.1016/j.jvir.2012.10.004

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  24 in total

1.  An Update on Methods for Revascularization and Expansion of the TASC Lesion Classification to Include Below-the-Knee Arteries: A Supplement to the Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II): The TASC Steering Comittee(.).

Authors:  Michael R Jaff; Christopher J White; William R Hiatt; Gerry R Fowkes; John Dormandy; Mahmood Razavi; Jim Reekers; Lars Norgren
Journal:  Ann Vasc Dis       Date:  2015-10-23

Review 2.  [Stent-assisted recanalization of femoropopliteal arterial occlusive disease. Influence of stent design on patency rates].

Authors:  M Treitl; M F Reiser; K M Treitl
Journal:  Radiologe       Date:  2016-03       Impact factor: 0.635

Review 3.  Endovascular intervention for peripheral artery disease.

Authors:  Arun K Thukkani; Scott Kinlay
Journal:  Circ Res       Date:  2015-04-24       Impact factor: 17.367

Review 4.  Percutaneous versus surgical management of lower extremity peripheral artery disease.

Authors:  Amit M Kakkar; J Dawn Abbott
Journal:  Curr Atheroscler Rep       Date:  2015       Impact factor: 5.113

5.  Superficial Femoral Artery Intervention: Creating an Algorithmic Approach for the Use of Old and Novel (Endovascular) Technologies.

Authors:  John H Rundback; Kevin Chaim Herman; Amish Patel
Journal:  Curr Treat Options Cardiovasc Med       Date:  2015-09

6.  Techniques in Vascular and Interventional Radiology Drug Delivery Technologies in the Superficial Femoral Artery.

Authors:  Akshaar Brahmbhatt; Sanjay Misra
Journal:  Tech Vasc Interv Radiol       Date:  2016-05-05

7.  Nitinol self-expanding stents vs. balloon angioplasty for very long femoropopliteal lesions.

Authors:  Ehrin J Armstrong; Haseeb Saeed; Bejan Alvandi; Satinder Singh; Gagan D Singh; Khung Keong Yeo; David Anderson; Gregory G Westin; David L Dawson; William C Pevec; John R Laird
Journal:  J Endovasc Ther       Date:  2014-02       Impact factor: 3.487

8.  Complications associated with the Rotarex® wire in a patient with peripheral artery disease.

Authors:  Donghoon Han; Dong-Geum Shin; Min-Kyung Kang; Jung Rae Cho; Seonghoon Choi; Namho Lee; Jong-Wook Lee; Yoon Haeng Cho
Journal:  Clin Case Rep       Date:  2021-05-24

9.  A rechargeable anti-thrombotic coating for blood-contacting devices.

Authors:  Hyun Ok Ham; Carolyn A Haller; Guowei Su; Erbin Dai; Madhukar S Patel; David R Liu; Jian Liu; Elliot L Chaikof
Journal:  Biomaterials       Date:  2021-07-09       Impact factor: 15.304

10.  Drug-coated balloon versus standard percutaneous transluminal angioplasty for the treatment of superficial femoral and popliteal peripheral artery disease: 12-month results from the IN.PACT SFA randomized trial.

Authors:  Gunnar Tepe; John Laird; Peter Schneider; Marianne Brodmann; Prakash Krishnan; Antonio Micari; Christopher Metzger; Dierk Scheinert; Thomas Zeller; David J Cohen; David B Snead; Beaux Alexander; Mario Landini; Michael R Jaff
Journal:  Circulation       Date:  2014-12-03       Impact factor: 29.690

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.