An interesting application of lung ultrasonography.

Paul H Mayo.   

Abstract

In the previous issue of Critical Care, Raimondi and colleagues investigate whether lung ultrasonography has utility for the assessment of respiratory distress in the neonate. This commentary reviews the results and implications of their study.

Entities:  

Mesh:

Year:  2013        PMID: 23369203      PMCID: PMC4056633          DOI: 10.1186/cc11914

Source DB:  PubMed          Journal:  Crit Care        ISSN: 1364-8535            Impact factor:   9.097


Lung ultrasonography has strong utility in adult critical care medicine, where it is a key element in the diagnosis and management of respiratory failure. In their welldesigned study, Raimondi and colleagues [1] describe an interesting application of lung ultrasonography to neonatology. They used ultrasonography to examine the lungs of babies at birth and serially at 24 and 36 hours post-delivery. They found a close correlation between the results of lung ultrasonography and the development of respiratory distress (RD) of the newborn. The positive and negative predictive value of the test indicates that it has major value in identifying neonates who are at risk for RD following delivery. Their results raise the consideration that ultrasonography should become the primary imaging modality for assessment of the neonatal lung. Given this possibility, Lichtenstein [2,3] has determined that the findings of lung ultrasonography in the neonatal population are identical to those found in the adult patient. Such key findings as A lines, B lines, consolidation, pleural effusion, or lung sliding, which have been described in the seminal work of Dr Lichtenstein [4], apply equally to the adult as to the neonate. When it comes to lung ultrasonography, a baby is simply an adult in miniature. The critical care clinician may confidently use the principles of lung ultrasonography across the entire age spectrum. When scanning the adult patient, the intensivist may face impediments in performing a comprehensive thoracic examination. The patient is in the supine position and may be difficult to position for a full examination, making it difficult to examine the postero-lateral thorax. Obesity, edema, or heavy musculature may degrade image quality. These are not considerations with the neonate, where the examination is characterized by ease of use. As the depth of examination is only a few centimeters, a high frequency transducer is used to yield images of excellent resolution. The transducer may be swept over the thorax in a series of scan lines to yield a high resolution image set of the entire lung. The examination may be easily repeated as often as needed. A portable ultrasound machine may be used to scan the lungs of multiple patients in the neonatal intensive unit and the delivery area for immediate assessment of risk for RD. The machine is not limited to use for scanning the lung and pleura, as ultrasonography has many other applications for the neonatologist and the pediatrician. A special reason to consider that ultrasonography should be the primary imaging modality for the neonate (or for all pediatric patients), is that it reduces the exposure of patients to ionizing radiation. The pediatric patient is at particular risk for the carcinogenic effects of radiation exposure. Every time that an ultrasound examination replaces a standard radiograph or a CT scan, benefit accrues to the patient in terms of reducing risk of cancer later in their life. The importance of this issue cannot be overstated. One of the practical impediments to the widespread use of ultrasonography is that some intensivists may still consider it as a traditional radiographic procedure, that is, an examination that is ordered by the bedside clinician but that is delayed in its performance, delayed in its interpretation, and interpreted by an offline reader with no deep understanding of the case. Intensivists should deploy ultrasonography using a different paradigm. The scan is done at point of care by the frontline clinician. The images are immediately interpreted by the clinician, and the results are immediately applied within the context of full knowledge of the clinical situation. The indicated ultrasound is repeated as often as is clinically indicated in order to observe the trajectory of the disease process, to guide management, and to examine for additional diagnosis or complications. While the study of Raimondi and colleagues shows that lung ultrasonography has excellent utility for assessment of RD in the neonate, it also presents to the critical care community an excellent example of point of care ultrasonography performed by the clinician and used for immediate clinical judgment call. It is an excellent example of the paradigm that brings ultrasonography to its best place: at the bedside of the patient. The study shows that lung ultrasonography may replace standard radiography for assessment of neonatal RD; and, by implication, for assessment of patients with other forms of respiratory failure in the critical care unit. Several European groups have done impressive work in defining the utility of lung ultrasonography in critical care medicine [5-13]. It is possible that critical care ultrasonographers may declare the death of the standard chest radiograph [14,15]. The usual intensive care unit chest radiograph, supine, rotated, and with uncertain penetration; is far outclassed by lung ultrasonography. Similarly, lung ultrasonography may largely replace chest CT with its heavy radiation exposure. Only then will ultrasonography reach its full potential at the bedside of the critically ill. To reach that point, faculty must recognize that a major challenge with lung ultrasonography remains that it requires training. Raimondi and colleagues are expert level ultrasonographers. All intensivists should be at their level. The issue is to design training programs that assure competence for intensivists in this key aspect of critical care ultrasonography

Abbreviations

RD: respiratory distress.

Competing interests

The author declares that they have no competing interests.
  13 in total

1.  Lung ultrasound characteristics of community-acquired pneumonia in hospitalized children.

Authors:  Vito Antonio Caiulo; Luna Gargani; Silvana Caiulo; Andrea Fisicaro; Fulvio Moramarco; Giuseppe Latini; Eugenio Picano; Giuseppe Mele
Journal:  Pediatr Pulmonol       Date:  2012-05-02

2.  Thoracic ultrasound for diagnosing pulmonary embolism: a prospective multicenter study of 352 patients.

Authors:  Gebhard Mathis; Wolfgang Blank; Angelika Reissig; Peter Lechleitner; Joachim Reuss; Andreas Schuler; Sonja Beckh
Journal:  Chest       Date:  2005-09       Impact factor: 9.410

3.  An integrated approach for prescribing fewer chest x-rays in the ICU.

Authors:  Vincent Ioos; Arnaud Galbois; Ludivine Chalumeau-Lemoine; Bertrand Guidet; Eric Maury; Gilles Hejblum
Journal:  Ann Intensive Care       Date:  2011-03-21       Impact factor: 6.925

4.  Bedside ultrasound assessment of positive end-expiratory pressure-induced lung recruitment.

Authors:  Belaïd Bouhemad; Hélène Brisson; Morgan Le-Guen; Charlotte Arbelot; Qin Lu; Jean-Jacques Rouby
Journal:  Am J Respir Crit Care Med       Date:  2010-09-17       Impact factor: 21.405

5.  Can chest ultrasonography replace standard chest radiography for evaluation of acute dyspnea in the ED?

Authors:  Maurizio Zanobetti; Claudio Poggioni; Riccardo Pini
Journal:  Chest       Date:  2010-10-14       Impact factor: 9.410

6.  Ultrasound assessment of antibiotic-induced pulmonary reaeration in ventilator-associated pneumonia.

Authors:  Bélaïd Bouhemad; Zhi-Hai Liu; Charlotte Arbelot; Mao Zhang; Fabio Ferarri; Morgan Le-Guen; Martin Girard; Qin Lu; Jean-Jacques Rouby
Journal:  Crit Care Med       Date:  2010-01       Impact factor: 7.598

7.  Relevance of lung ultrasound in the diagnosis of acute respiratory failure: the BLUE protocol.

Authors:  Daniel A Lichtenstein; Gilbert A Mezière
Journal:  Chest       Date:  2008-04-10       Impact factor: 9.410

Review 8.  Lung ultrasound in acute respiratory distress syndrome and acute lung injury.

Authors:  Charlotte Arbelot; Fabio Ferrari; Belaïd Bouhemad; Jean-Jacques Rouby
Journal:  Curr Opin Crit Care       Date:  2008-02       Impact factor: 3.687

9.  Can neonatal lung ultrasound monitor fluid clearance and predict the need of respiratory support?

Authors:  Francesco Raimondi; Fiorella Migliaro; Angela Sodano; Angela Umbaldo; Antonia Romano; Gianfranco Vallone; Letizia Capasso
Journal:  Crit Care       Date:  2012-11-14       Impact factor: 9.097

10.  Chest sonography: a useful tool to differentiate acute cardiogenic pulmonary edema from acute respiratory distress syndrome.

Authors:  Roberto Copetti; Gino Soldati; Paolo Copetti
Journal:  Cardiovasc Ultrasound       Date:  2008-04-29       Impact factor: 2.062

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.