Literature DB >> 23369006

Changes in exhaled breath condensate pH in healthy and asthmatic pregnant women.

Noémi Eszes1, András Bikov, Zsófia Lázár, Anikó Bohács, Veronika Müller, Balázs Stenczer, János Rigó, György Losonczy, Ildikó Horváth, Lilla Tamási.   

Abstract

OBJECTIVE: Asthma is a common chronic disease complicating pregnancy with a risk for perinatal complications. Control of airway inflammation in the asthmatic pregnancy improves pregnancy outcomes. Our aim was to evaluate pH of exhaled breath condensate (EBC), a non-invasive method for the assessment of asthmatic airway inflammation, in healthy and asthmatic pregnancies.
DESIGN: Cross-sectional study.
SETTING: Hungarian university clinics. POPULATION: Seventeen healthy pregnant women, 21 asthmatic pregnant women, 23 healthy non-pregnant women and 22 asthmatic non-pregnant women.
METHODS: EBC samples were collected using a portable condenser, EBC pH was measured after argon deaeration. MAIN OUTCOME MEASURE: EBC pH.
RESULTS: EBC pH (mean ± SD) of healthy non-pregnant and asthmatic non-pregnant women was similar (7.75 ± 0.27 vs. 7.54 ± 0.57; p = 0.118), probably indicating an optimal control of airway inflammation in asthmatic women. On the other hand, EBC pH was higher in healthy pregnant women compared with healthy non-pregnant women (8.02 ± 0.43 vs. 7.75 ± 0.27; p = 0.017). Higher EBC pH accompanying healthy pregnancy was absent in asthmatic pregnant patients whose EBC pH was lower (7.65 ± 0.38) than that of healthy pregnant women (p = 0.006), and it was similar to that in asthmatic and healthy non-pregnant women (p = 0.470 and p = 0.300, respectively). The EBC pH in asthmatic pregnant women correlated positively with birthweight (r = 0.49, p = 0.047) and negatively with forced vital capacity (r = 0.45, p = 0.039). EBC pH was not related to blood pH.
CONCLUSIONS: EBC pH is higher in healthy pregnant women but not in asthmatic pregnant women compared with data from healthy non-pregnant women, indicating that oxidative inflammatory processes induced by asthma may compromise the regulatory mechanisms causing alkaline pH in the airways during pregnancy.
© 2013 The Authors Acta Obstetricia et Gynecologica Scandinavica © 2013 Nordic Federation of Societies of Obstetrics and Gynecology.

Entities:  

Mesh:

Year:  2013        PMID: 23369006     DOI: 10.1111/aogs.12094

Source DB:  PubMed          Journal:  Acta Obstet Gynecol Scand        ISSN: 0001-6349            Impact factor:   3.636


  1 in total

1.  Specific Metabolome Profile of Exhaled Breath Condensate in Patients with Shock and Respiratory Failure: A Pilot Study.

Authors:  Brice Fermier; Hélène Blasco; Emmanuel Godat; Cinzia Bocca; Joseph Moënne-Loccoz; Patrick Emond; Christian R Andres; Marc Laffon; Martine Ferrandière
Journal:  Metabolites       Date:  2016-09-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.