Literature DB >> 23367280

A data mining approach to reduce the false alarm rate of patient monitors.

Benedikt Baumgartner1, Kolja Rödel, Alois Knoll.   

Abstract

Patient monitors in intensive care units trigger alarms if the state of the patient deteriorates or if there is a technical problem, e.g. loose sensors. Monitoring systems have a high sensitivity in order to detect relevant changes in the patient state. However, multiple studies revealed a high rate of either false or clinically not relevant alarms. It was found that the high rate of false alarms has a negative impact on both patients and staff. In this study we apply data mining methods to reduce the false alarm rate of monitoring systems. We follow a multi-parameter approach where multiple signals of a monitoring system are used to classify given alarm situations. In particular we focus on five alarm types and let our system decide whether the triggered alarm is clinically relevant or can be considered as a false alarm. Several classification algorithms (Naive Bayes, Decision Trees, SVM, kNN and Multi-Layer Perceptron) were evaluated. For training and test sets a subset of the freely available MIMIC II database was used. Alarm-specific classification accuracy was between 78.56% and 98.84%. Suppression rates for false alarms were between 75.24% and 99.23%. Classification results strongly depend on available training data, which is still limited in the intensive care domain. However, this study shows that data mining methods are useful and applicable for alarm classification.

Entities:  

Mesh:

Year:  2012        PMID: 23367280     DOI: 10.1109/EMBC.2012.6347345

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  3 in total

1.  Sensor fusion methods for reducing false alarms in heart rate monitoring.

Authors:  Gabriel Borges; Valner Brusamarello
Journal:  J Clin Monit Comput       Date:  2015-10-06       Impact factor: 2.502

2.  Predictive Monitoring of Critical Cardiorespiratory Alarms in Neonates Under Intensive Care.

Authors:  Rohan Joshi; Zheng Peng; Xi Long; Loe Feijs; Peter Andriessen; Carola Van Pul
Journal:  IEEE J Transl Eng Health Med       Date:  2019-11-22       Impact factor: 3.316

3.  Actionable Ventricular Tachycardia During In-Hospital ECG Monitoring and Its Impact on Alarm Fatigue.

Authors:  Michele M Pelter; Sukardi Suba; Cass Sandoval; Jessica K Zègre-Hemsey; Sarah Berger; Amy Larsen; Fabio Badilini; Xiao Hu
Journal:  Crit Pathw Cardiol       Date:  2020-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.