Comparison Between 3D TOF Magnetic Resonance Angiography and Intraarterial Digital Subtraction Angiography in Imaging the Circle of Willis.

Rozita Mohd Ghazali1, Ibrahim Lutfi Shuaib.   

Abstract

This study was done compare the accuracy of non-contrast enhanced 3D time of flight magnetic resonance angiography (3D TOF MRA) with intraarterial digital subtraction angiography (IADSA) in depicting the arterial segments of the circle of Willis. 398 arterial segments were analysed from 38 patients who underwent both non-contrast enhanced 3D TOF MRA and IADSA examinations in Hospital Universiti Sains Malaysia from November 1998 to December 2000. Two observers performed blinded retrospective analysis of the IADSA images and Maximum Intensity Projection display of the 3D TOF MRA of the circle of Willis on separate sessions. Non-contrast enhanced 3D TOF MRA was sensitive and specific in depicting the A1, A2, M1, P1 and Anterior Communicating segments of the circle of Willis with a sensitivity ranging from 94.5% to 100% and specificity ranging from 90.5% to 100%. However it was poor in depicting the Posterior Communicating segments with a sensitivity of 21.4%. MIP display of the non-contrast enhanced 3D TOF MRA is sensitive in depicting the anatomy of the circle of Willis except for the PCOM segment. It is thus a reliable method for screening of this arterial circle.

Entities:  

Keywords:  3D TOF MRA; IADSA; circle of Willis

Year:  2003        PMID: 23365498      PMCID: PMC3557107     

Source DB:  PubMed          Journal:  Malays J Med Sci        ISSN: 1394-195X


  5 in total

1.  Anatomic evaluation of the circle of Willis: MR angiography versus intraarterial digital subtraction angiography.

Authors:  K W Stock; S Wetzel; E Kirsch; G Bongartz; W Steinbrich; E W Radue
Journal:  AJNR Am J Neuroradiol       Date:  1996-09       Impact factor: 3.825

2.  Circle of Willis: evaluation with spiral CT angiography, MR angiography, and conventional angiography.

Authors:  D A Katz; M P Marks; S A Napel; P M Bracci; S L Roberts
Journal:  Radiology       Date:  1995-05       Impact factor: 11.105

Review 3.  Basic concepts in magnetic resonance angiography.

Authors:  S Sheppard
Journal:  Radiol Clin North Am       Date:  1995-01       Impact factor: 2.303

4.  Magnetic resonance angiography (MRA) of the circle of Willis: a prospective comparison with conventional angiography in 54 subjects.

Authors:  B Patrux; J P Laissy; S Jouini; W Kawiecki; P Coty; J Thiébot
Journal:  Neuroradiology       Date:  1994-04       Impact factor: 2.804

5.  Circle of Willis: morphologic variation on three-dimensional time-of-flight MR angiograms.

Authors:  M J Krabbe-Hartkamp; J van der Grond; F E de Leeuw; J C de Groot; A Algra; B Hillen; M M Breteler; W P Mali
Journal:  Radiology       Date:  1998-04       Impact factor: 11.105

  5 in total
  2 in total

1.  In Vivo Validation of Simultaneous Non-Contrast Angiography and intraPlaque Hemorrhage (SNAP) Magnetic Resonance Angiography: An Intracranial Artery Study.

Authors:  Jinnan Wang; Maobin Guan; Kiyofumi Yamada; Daniel S Hippe; William S Kerwin; Chun Yuan; Peter Börnert; Xihai Zhao
Journal:  PLoS One       Date:  2016-02-10       Impact factor: 3.240

2.  Magnetic resonance angiography determined variations in the circle of Willis: Analysis of a large series from a single center.

Authors:  Reddy Ravikanth; Babu Philip
Journal:  Ci Ji Yi Xue Za Zhi       Date:  2019 Jan-Mar
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.