Literature DB >> 23364950

Single file reciprocating technique using conventional nickel-titanium rotary endodontic files.

So-Youn Jin1, WooCheol Lee, Mo K Kang, Bock Hur, Hyeon-Cheol Kim.   

Abstract

This study was aimed to evaluate the applicability of a reciprocating movement technique with conventional nickel-titanium files for root canal preparation. Forty-four simulated canals in resin blocks were used in this study and divided as following four groups according to the instruments used and preparation methods. Group CP (n = 12) and CR (n = 12) were instrumented with continuous rotation using four files of ProFile and RaCe, respectively. Group RP (n = 10) and RR (n = 10) were instrumented with a reciprocation movement by using a single ProFile and RaCe file, respectively. The resin blocks were scanned before and after instrumentation, and the images were superimposed. To compare the efficiency of canal shaping, the preparation time, and centering ratio were calculated. Morphologic changes of tested files were examined by scanning electron microscopy (SEM). Data were analyzed by ANOVA and Duncan's post hoc test at p < 0.05. The preparation time was markedly shorter in Groups RP and RR than in Groups CP and CR. No significant difference in the centering ratio was noted between groups. Although the files used for Groups CP and CR showed no distortion under the SEM evaluation, the files used for Groups RP and RR had considerable torsional distortion. This study suggests that the reciprocating instrumentation technique using conventional nickel-titanium rotary file systems might have a comparable efficacy for the root canal shaping with reduced shaping time. Although the reciprocating technique seems to be an effective alternative to the conventional rotation technique, the risk of torsional distortion and fracture should be considered before clinical application. © Wiley Periodicals, Inc.

Entities:  

Keywords:  continuous rotation; nickel-titanium endodontic rotary file; reciprocating; shaping efficacy; torsional fracture

Mesh:

Substances:

Year:  2013        PMID: 23364950     DOI: 10.1002/sca.21074

Source DB:  PubMed          Journal:  Scanning        ISSN: 0161-0457            Impact factor:   1.932


  6 in total

1.  Preference of undergraduate students after first experience on nickel-titanium endodontic instruments.

Authors:  Sang Won Kwak; Gary Shun-Pan Cheung; Jung-Hong Ha; Sung Kyo Kim; Hyojin Lee; Hyeon-Cheol Kim
Journal:  Restor Dent Endod       Date:  2016-06-23

2.  Shaping ability of the profile 25/0.06 and protaper F2 in rotary motion, and reciproc in simulated canals.

Authors:  Gül Çelik; Murat Maden; Ahmet Savgat; Hikmet Orhan
Journal:  PeerJ       Date:  2018-12-14       Impact factor: 2.984

3.  Analysis of the Morpho-Geometrical Changes of the Root Canal System Produced by TF Adaptive vs. BioRace: A Micro-Computed Tomography Study.

Authors:  Loai Alsofi; Muhannad Al Harbi; Martin Stauber; Khaled Balto
Journal:  Materials (Basel)       Date:  2021-01-22       Impact factor: 3.623

4.  Effect of Rotary and Reciprocating Instrumentation Motions on Postoperative Pain Incidence in Non-Surgical Endodontic Treatments: A Systematic Review and Meta-Analysis.

Authors:  Behnam Rahbani Nobar; Omid Dianat; Behrad Rahbani Nobar; Armin Shirvani; Nazanin Zargar; Majid Kazem; Patricia Tordik
Journal:  Eur Endod J       Date:  2021-02-02

5.  Influence of glide path size and operating kinetics on time to reach working length and fracture resistance of Twisted File adaptive and Endostar E3 nickel-titanium file systems.

Authors:  Tamilkumaran Ramyadharshini; Inbaraj Anand Sherwood; V Shanmugham Vigneshwar; Prakasam Ernest Prince; Murugadoss Vaanjay
Journal:  Restor Dent Endod       Date:  2020-03-05

6.  Evaluation of Postoperative Pain Following Single-Visit Root Canal Treatment with Rotary and Reciprocal Ni-Ti File Systems in Children.

Authors:  Alp Abidin Atesci; Aslı Topaloglu-Ak; Ece Turan; Ozant Oncag; Mehmet Emin Kaval
Journal:  Medicina (Kaunas)       Date:  2021-12-29       Impact factor: 2.430

  6 in total