Difference in neointimal appearance between early and late restenosis after sirolimus-eluting stent implantation assessed by optical coherence tomography.

Yasushi Ino1, Takashi Kubo, Hironori Kitabata, Kohei Ishibashi, Takashi Tanimoto, Yoshiki Matsuo, Kunihiro Shimamura, Yasutsugu Shiono, Makoto Orii, Kenichi Komukai, Takashi Yamano, Tomoyuki Yamaguchi, Kumiko Hirata, Atsushi Tanaka, Masato Mizukoshi, Toshio Imanishi, Takashi Akasaka.   

Abstract

OBJECTIVES: Late in-stent restenosis (ISR) is an important clinical issue in the drug-eluting stent era. Autopsy studies have reported different underlying mechanisms between early ISR and late ISR. The aim of the present study was to compare the neointimal tissue appearance between early ISR (<1 year) and late ISR (>1 year) after sirolimus-eluting stent (SES) implantation using optical coherence tomography (OCT).
MATERIALS AND METHODS: We examined the neointimal tissue appearance in 48 ISR lesions after SES implantation [30 early ISR lesions (8±1 months after stenting) and 18 late ISR lesions (34±14 months after stenting)] by OCT. ISR was defined as percent diameter stenosis more than 50% within the stented segment in angiography. Lipid-rich neointima was characterized by signal-poor regions with diffuse borders. Thin-cap fibroatheroma (TCFA)-like neointima was defined by lipid-rich neointima with cap thickness 65 μm or less.
RESULTS: In the OCT findings, heterogeneous neointima was more often observed in the late ISR group compared with the early ISR group (89 vs. 43%, P=0.002). Although the frequency of intraluminal thrombus was not different between the two groups (P=0.085), the frequency of lipid-rich neointima (83 vs. 27%, P<0.001), TCFA-like neointima (39 vs. 10%, P=0.028), microchannels within neointima (67 vs. 27%, P=0.007), and neointimal disruption (33 vs. 3%, P=0.008) was significantly higher in the late ISR group.
CONCLUSION: In the present OCT study, it was found that atherosclerotic progression of neointima, such as lipid-rich neointima, TCFA-like neointima, microchannels, and neointimal disruption, was more often observed in late ISR lesions after SES implantation compared with early ISR ones.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23363984     DOI: 10.1097/MCA.0b013e32835c872b

Source DB:  PubMed          Journal:  Coron Artery Dis        ISSN: 0954-6928            Impact factor:   1.439


  3 in total

1.  Factors Associated with Lipid Goal Attainment among Patients with Deployed Drug Eluting Stent.

Authors:  Min-I Su; Cheng-Ting Tsai; Hung-I Yeh; Chun-Yen Chen
Journal:  Acta Cardiol Sin       Date:  2014-07       Impact factor: 2.672

Review 2.  Practical application of coronary imaging devices in cardiovascular intervention.

Authors:  Yun-Kyeong Cho; Seung-Ho Hur
Journal:  Korean Circ J       Date:  2015-03-24       Impact factor: 3.243

Review 3.  OCT demonstrating neoatherosclerosis as part of the continuous process of coronary artery disease.

Authors:  B-C Zhang; A Karanasos; E Regar
Journal:  Herz       Date:  2015-09       Impact factor: 1.443

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.