Literature DB >> 23363207

On the importance of modeling stent procedure for predicting arterial mechanics.

Shijia Zhao1, Linxia Gu, Stacey R Froemming.   

Abstract

The stent-artery interactions have been increasingly studied using the finite element method for better understanding of the biomechanical environment changes on the artery and its implications. However, the deployment of balloon-expandable stents was generally simplified without considering the balloon-stent interactions, the initial crimping process of the stent, its overexpansion routinely used in the clinical practice, or its recoil process. In this work, the stenting procedure was mimicked by incorporating all the above-mentioned simplifications. The impact of various simplifications on the stent-induced arterial stresses was systematically investigated. The plastic strain history of stent and its resulted geometrical variations, as well as arterial mechanics were quantified and compared. Results showed the model without considering the stent crimping process underestimating the minimum stent diameter by 17.2%, and overestimating the maximum radial recoil by 144%. It was also suggested that overexpansion resulted in a larger stent diameter, but a greater radial recoil ratio and larger intimal area with high stress were also obtained along with the increase in degree of overexpansion.

Mesh:

Year:  2012        PMID: 23363207     DOI: 10.1115/1.4023094

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  8 in total

1.  Target Lesion Calcium Arc Influence the Performance of Stenting.

Authors:  Pengfei Dong; Shengmao Lin; David L Wilson; Hiram G Bezerra; Linxia Gu
Journal:  2017 Des Med Devices Conf (2017)       Date:  2017-04

2.  Co-registration of pre- and post-stent intravascular OCT images for validation of finite element model simulation of stent expansion.

Authors:  Yazan Gharaibeh; Juhwan Lee; David Prabhu; Pengfei Dong; Vladislav N Zimin; Luis A Dallan; Hiram Bezerra; Linxia Gu; David Wilson
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2020-02-28

3.  MECHANICAL PERFORMANCE OF PLLA STENT.

Authors:  Longzhen Wang; Junfei Tong; Pengfei Dong; David L Wilson; Hiram G Bezerra; Linxia Gu
Journal:  2018 Des Med Devices Conf (2018)       Date:  2018-04

4.  IMPACT OF CALCIUM QUANTIFICATIONS ON STENT EXPANSIONS.

Authors:  Pengfei Dong; Hiram G Bezerra; David L Wilson; Linxia Gu
Journal:  J Biomech Eng       Date:  2018-11-15       Impact factor: 2.097

5.  Two-stage degradation and novel functional endothelium characteristics of a 3-D printed bioresorbable scaffold.

Authors:  Tieying Yin; Ruolin Du; Yang Wang; Junyang Huang; Shuang Ge; Yuhua Huang; Youhua Tan; Qing Liu; Zhong Chen; Hanqing Feng; Jie Du; Yazhou Wang; Guixue Wang
Journal:  Bioact Mater       Date:  2021-08-24

6.  Simulation-Driven Machine Learning for Predicting Stent Expansion in Calcified Coronary Artery.

Authors:  Pengfei Dong; Guochang Ye; Mehmet Kaya; Linxia Gu
Journal:  Appl Sci (Basel)       Date:  2020-08-22       Impact factor: 2.838

Review 7.  Recent Advances in Manufacturing Innovative Stents.

Authors:  Natalia Beshchasna; Muhammad Saqib; Honorata Kraskiewicz; Łukasz Wasyluk; Oleg Kuzmin; Oana Cristina Duta; Denisa Ficai; Zeno Ghizdavet; Alexandru Marin; Anton Ficai; Zhilei Sun; Vladimir F Pichugin; Joerg Opitz; Ecaterina Andronescu
Journal:  Pharmaceutics       Date:  2020-04-13       Impact factor: 6.321

8.  Experimentally validated simulation of coronary stents considering different dogboning ratios and asymmetric stent positioning.

Authors:  Lisa Wiesent; Ulrich Schultheiß; Christof Schmid; Thomas Schratzenstaller; Aida Nonn
Journal:  PLoS One       Date:  2019-10-18       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.