| Literature DB >> 23362433 |
Marek Roslan1, Marcin M Markuszewski, Joanna Bagińska, Kazimierz Krajka.
Abstract
Some minimally invasive techniques have been introduced to decrease morbidity related to standard laparoscopic procedures. One such approach is laparoendoscopic single-site surgery (LESS), which can also be applied for transvesical surgery. The aim of the study was to present our initial clinical experience of using this technique for transvesical vesicovaginal fistula (VVF) repair. In August 2011, we carried out the LESS repair of a 3-mm in diameter vesicovaginal fistula on a 72-year-old woman, who failed the conservative treatment with Foley placement. The procedure was performed transvesically (percutaneous intraluminal approach) with a single-port device (4-channel, TriPort+, Olympus Winter&IBE GMBH) via a 1.5-cm incision made 2 cm above the pubic symphysis. A standard 10-mm optic and straight laparoscopic instruments were used. The fistulous tract was dissected and partially excised. The bladder and vaginal wall defects were closed in two layers with running absorbable V-Loc (Covidien, Norwalk, CT, USA) suture. Ureteral catheters were left for 5 days and the Foley catheter for 14 days. The operative time was 170 min. The blood loss was minimal. No complications were observed. The postoperative period was uneventful. During a 6-month follow-up the patient reported no involuntary discharge of urine into the vagina. Diagnostic scans revealed no presence of VVF and laboratory examination results were all within the normal range. Although substantial development of the instruments and skills is needed, the transvesical LESS vesicovaginal fistula repair appeared to be feasible and safe. Nevertheless, further experience and observations are necessary.Entities:
Keywords: laparoendoscopic single-site surgery; minimally invasive surgery; vesicovaginal fistula
Year: 2012 PMID: 23362433 PMCID: PMC3557738 DOI: 10.5114/wiitm.2011.30816
Source DB: PubMed Journal: Wideochir Inne Tech Maloinwazyjne ISSN: 1895-4588 Impact factor: 1.195
Figure 1A cystourethrography scan shows contrast medium leaking into the vagina
Figure 2Intraoperative photographs. A – Ureteric catheterization to safeguard the ureters. Note another ureteric catheter through the fistula. B – Circuitous dissection of the VVF orifice from the bladder mucosa with a hook electrode. C – Developing a plane between the bladder and the anterior vaginal wall. D – Closure of the vaginal defect with a 3/0 absorbable running suture (V-Loc). E – Closure of the bladder defect with a 3/0 absorbable running suture (V-Loc)
Figure 3A postoperative cystogram obtained 7 weeks later does not show any leak