Literature DB >> 23360391

Brief report: Comparison of continuous glucose monitoring and finger-prick blood glucose levels in hospitalized patients administered basal-bolus insulin.

Morton G Burt1, Gregory W Roberts, Norma R Aguilar-Loza, Stephen N Stranks.   

Abstract

BACKGROUND: Previous studies have assessed the efficacy of basal-bolus insulin (BBI) in hospitalized patients by measuring four finger-prick blood glucose levels (BGLs) per day. The aim of this study was to investigate whether this BGL monitoring regimen provides an accurate reflection of glycemia in hospitalized patients administered BBI. We hypothesized that, as three of four readings are preprandial, finger-prick BGLs would underestimate the mean glucose concentration. SUBJECTS AND METHODS: Twenty-six consecutive consenting subjects with type 1 (n=3) or type 2 (n=23) diabetes mellitus admitted to the hospital and administered insulin glargine once daily and rapid-acting insulin before meals underwent continuous glucose monitoring for up to 72 h. Finger-prick BGLs were performed before each main meal (0700, 1200, and 1700 h) and at 2100 h.
RESULTS: Mean daily glucose concentration was not significantly different when assessed by continuous glucose monitoring and finger-prick BGLs (9.6±2.4 vs. 9.6±2.7 mmol/L, P=0.84). A Bland-Altman plot revealed some variability but no bias between the two methods of measurement of glucose concentration. There were 88 postprandial hyperglycemic excursions recorded on continuous glucose monitoring; 61 (69%) were identified by finger-prick BGL monitoring. There were 10 glucose excursions <4 mmol/L during continuous glucose monitoring; only one was detected by finger-prick BGL monitoring.
CONCLUSIONS: Traditional finger-prick BGL monitoring provides a reasonable approximation of mean daily glucose concentration in the majority of hospitalized patients receiving BBI but underestimates the prevalence of postprandial hyperglycemia and hypoglycemia.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23360391     DOI: 10.1089/dia.2012.0282

Source DB:  PubMed          Journal:  Diabetes Technol Ther        ISSN: 1520-9156            Impact factor:   6.118


  22 in total

Review 1.  Diabetes Technology in the Inpatient Setting for Management of Hyperglycemia.

Authors:  Georgia M Davis; Rodolfo J Galindo; Alexandra L Migdal; Guillermo E Umpierrez
Journal:  Endocrinol Metab Clin North Am       Date:  2020-03       Impact factor: 4.741

Review 2.  Designing the Glucose Telemetry for Hospital Management: From Bedside to the Nursing Station.

Authors:  Medha Satyarengga; Tariq Siddiqui; Elias K Spanakis
Journal:  Curr Diab Rep       Date:  2018-08-29       Impact factor: 4.810

3.  Consensus Statement on Inpatient Use of Continuous Glucose Monitoring.

Authors:  Amisha Wallia; Guillermo E Umpierrez; Robert J Rushakoff; David C Klonoff; Daniel J Rubin; Sherita Hill Golden; Curtiss B Cook; Bithika Thompson
Journal:  J Diabetes Sci Technol       Date:  2017-04-21

4.  Hypoglycemia Incidence and Factors Associated in a Cohort of Patients With Type 2 Diabetes Hospitalized in General Ward Treated With Basal Bolus Insulin Regimen Assessed by Continuous Glucose Monitoring.

Authors:  Ana María Gómez; Angélica Imitola Madero; Diana Cristina Henao Carrillo; Martín Rondón; Oscar Mauricio Muñoz; Maria Alejandra Robledo; Martín Rebolledo; Maira García Jaramillo; Fabian León Vargas; Guillermo Umpierrez
Journal:  J Diabetes Sci Technol       Date:  2019-01-24

Review 5.  Continuous glucose monitoring in insulin-treated patients in non-ICU settings.

Authors:  Ana Maria Gomez; Guillermo E Umpierrez
Journal:  J Diabetes Sci Technol       Date:  2014-08-13

6.  Mitigating Severe Hypoglycemia by Initiating Inpatient Continuous Glucose Monitoring for Type 1 Diabetes Mellitus.

Authors:  David L Levitt; Kristi D Silver; Elias K Spanakis
Journal:  J Diabetes Sci Technol       Date:  2016-08-20

7.  Insulin Pump and Continuous Glucose Monitor Initiation in Hospitalized Patients with Type 2 Diabetes Mellitus.

Authors:  David L Levitt; Elias K Spanakis; Kathleen A Ryan; Kristi D Silver
Journal:  Diabetes Technol Ther       Date:  2018-01-02       Impact factor: 6.118

8.  The Effect of Continuous Glucose Monitoring in Preventing Inpatient Hypoglycemia in General Wards: The Glucose Telemetry System.

Authors:  Elias K Spanakis; David L Levitt; Tariq Siddiqui; Lakshmi G Singh; Lillian Pinault; John Sorkin; Guillermo E Umpierrez; Jeffrey C Fink
Journal:  J Diabetes Sci Technol       Date:  2017-12-13

9.  Continuous Glucose Monitors and Automated Insulin Dosing Systems in the Hospital Consensus Guideline.

Authors:  Rodolfo J Galindo; Guillermo E Umpierrez; Robert J Rushakoff; Ananda Basu; Suzanne Lohnes; James H Nichols; Elias K Spanakis; Juan Espinoza; Nadine E Palermo; Dessa Garnett Awadjie; Leigh Bak; Bruce Buckingham; Curtiss B Cook; Guido Freckmann; Lutz Heinemann; Roman Hovorka; Nestoras Mathioudakis; Tonya Newman; David N O'Neal; Michaela Rickert; David B Sacks; Jane Jeffrie Seley; Amisha Wallia; Trisha Shang; Jennifer Y Zhang; Julia Han; David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2020-09-28

10.  Continuous Glucose Monitoring Versus Capillary Point-of-Care Testing for Inpatient Glycemic Control in Type 2 Diabetes Patients Hospitalized in the General Ward and Treated With a Basal Bolus Insulin Regimen.

Authors:  Ana M Gómez; Guillermo E Umpierrez; Oscar M Muñoz; Felipe Herrera; Claudia Rubio; Pablo Aschner; Richard Buendia
Journal:  J Diabetes Sci Technol       Date:  2015-08-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.