Literature DB >> 23357757

Reliability of principal components and discrete parameters of knee angle and moment gait waveforms in individuals with moderate knee osteoarthritis.

Shawn M Robbins1, Janie L Astephen Wilson, Derek J Rutherford, Cheryl L Hubley-Kozey.   

Abstract

Gait measures are used to evaluate change in patients with knee osteoarthritis (OA), but reliability has not been fully established in this population. This study examined test-retest reliability of knee angle and moment gait waveform characteristics captured using discrete parameters and principal component analysis (PCA) in individuals with moderate knee OA. Participants (n=20) underwent three-dimensional gait analysis on two occasions. Motion and force data were captured using two camera banks, infrared light emitting diodes and force plate during self-selected walking. Knee angle and moment waveforms were calculated and analyzed using discrete parameters and by identifying waveform characteristics using PCA. Intraclass correlation coefficients (ICC2,k) examined test-retest reliability of discrete parameters and PCA derived scores (PC-scores). ICC2,k values ranged from 0.57 to 0.93 for discrete parameters, 0.52-0.86 for knee angle PC-scores and 0.30-0.94 for the knee moment PC-scores. However, 10 of 13 discrete parameters, six of nine knee angle PC-scores and seven of nine knee moment PC-scores had ICC2,k values greater than or equal to 0.70. Discrete parameters and PC-scores from flexion angles and adduction moments had the highest ICC2,k values while adduction angles, rotation angles, and rotation moments had the lowest. Most knee angle and moment waveform characteristics demonstrated ICC2,k values that could be interpreted as acceptable. Caution should be used when examining adduction and rotation angle magnitudes and early/mid-stance rotation moment magnitudes due to lower ICC2,k values.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Biomechanics; Gait; Knee osteoarthritis; Principal component analysis; Reliability

Mesh:

Year:  2013        PMID: 23357757     DOI: 10.1016/j.gaitpost.2013.01.001

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  6 in total

1.  Evaluation of an ankle-foot orthosis effect on gait transitional stability during ramp ascent/descent.

Authors:  Imran Mahmood; Anam Raza; Hafiz Farhan Maqbool; Abbas A Dehghani-Sanij
Journal:  Med Biol Eng Comput       Date:  2022-05-21       Impact factor: 2.602

2.  Three-dimensional biomechanical gait characteristics at baseline are associated with progression to total knee arthroplasty.

Authors:  Gillian L Hatfield; William D Stanish; Cheryl L Hubley-Kozey
Journal:  Arthritis Care Res (Hoboken)       Date:  2015-07       Impact factor: 4.794

3.  Reliability of three-dimensional kinematic gait data in adults with spinal cord injury.

Authors:  Pia Wedege; Kathrin Steffen; Vegard Strøm; Arve Isak Opheim
Journal:  J Rehabil Assist Technol Eng       Date:  2017-09-14

4.  Statistical Modeling of Lower Limb Kinetics During Deep Squat and Forward Lunge.

Authors:  Joris De Roeck; J Van Houcke; D Almeida; P Galibarov; L De Roeck; Emmanuel A Audenaert
Journal:  Front Bioeng Biotechnol       Date:  2020-04-02

5.  Biomechanical Markers of Forward Hop-Landing After ACL-Reconstruction: A Pattern Recognition Approach.

Authors:  Prasanna Sritharan; Mario A Muñoz; Peter Pivonka; Adam L Bryant; Hossein Mokhtarzadeh; Luke G Perraton
Journal:  Ann Biomed Eng       Date:  2022-01-31       Impact factor: 3.934

6.  Test-retest reliability and sensitivity of the 20-meter walk test among patients with knee osteoarthritis.

Authors:  Jillian M Motyl; Jeffrey B Driban; Erica McAdams; Lori Lyn Price; Timothy E McAlindon
Journal:  BMC Musculoskelet Disord       Date:  2013-05-10       Impact factor: 2.362

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.