Literature DB >> 23353938

High-performance liquid chromatography using pressurized liquid extraction for the determination of seven tetracyclines in egg, fish and shrimp.

Yu Liu1, Hailan Yang, Sheng Yang, Qiwei Hu, Hongbo Cheng, Huiyu Liu, Yinsheng Qiu.   

Abstract

A simple and especially rapid method, pressurized liquid extraction, has been developed and applied to the quantitative determination of oxytetracycline, tetracycline, chlortetracycline, minocycline, methacycline, demeclocycline and doxycycline in egg, fish and shrimp. The procedure consisted of a trichloracetic acid/methanol extraction conducted at elevated temperature (60°C) and pressure (65bar), without further clean-up, the extraction solution was concentrated and finally for high-performance liquid chromatography analysis. The limits of detection were 5.0-10.0μg/kg and the limits of quantification were 10.0-15.0μg/kg for tetracyclines in egg, fish and shrimp using UV detection. The analytical limits CCα and CCβ were also calculated. The recoveries of tetracyclines spiked at levels of 15-300μg/kg, averaged 75.6-103.5% with the relative standard deviation values less than 11%. The optimized procedure has been successfully applied to real samples in our laboratories. It demonstrated that the new method was robust and useful for monitoring and quantification of 7 tetracycline residues in food of animal origin.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23353938     DOI: 10.1016/j.jchromb.2012.12.036

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  5 in total

1.  Occurrence and risk assessment of fluoroquinolones and tetracyclines in cultured fish from a coastal region of northern China.

Authors:  Sisi Liu; Guangbin Dong; Hongxia Zhao; Mo Chen; Wenna Quan; Baocheng Qu
Journal:  Environ Sci Pollut Res Int       Date:  2018-01-05       Impact factor: 4.223

2.  Visual and fluorometric lateral flow immunoassay combined with a dual-functional test mode for rapid determination of tetracycline antibiotics.

Authors:  Wei Sheng; Qing Chang; Yingjie Shi; Wenxia Duan; Yan Zhang; Shuo Wang
Journal:  Mikrochim Acta       Date:  2018-08-07       Impact factor: 5.833

Review 3.  Tetracyclines in Food and Feedingstuffs: From Regulation to Analytical Methods, Bacterial Resistance, and Environmental and Health Implications.

Authors:  Fabio Granados-Chinchilla; César Rodríguez
Journal:  J Anal Methods Chem       Date:  2017-01-12       Impact factor: 2.193

4.  Dual-Channel Probe of Carbon Dots Cooperating with Lanthanide Complex Employed for Simultaneously Distinguishing and Sequentially Detecting Tetracycline and Oxytetracycline.

Authors:  Lei Jia; Zhitao Xu; Rujie Chen; Xiangzhen Chen; Jun Xu
Journal:  Nanomaterials (Basel)       Date:  2021-12-31       Impact factor: 5.076

5.  Occurrence and human health risk assessment of antibiotics in cultured fish from 19 provinces in China.

Authors:  Yunyu Tang; Xiaoyi Lou; Guangxin Yang; Liangliang Tian; Yuan Wang; Xuanyun Huang
Journal:  Front Cell Infect Microbiol       Date:  2022-08-02       Impact factor: 6.073

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.