| Literature DB >> 2335326 |
K Sato1, K Tamaki, H Tsutsumi, H Okajima, Y Katsumata.
Abstract
Changes in methemoglobin (Met-Hb) concentrations during storage of whole blood or mixtures of blood and a cryoprotectant at refrigerated or various freezing temperatures were examined using blood samples from nitrite-administered rats and from autopsy cadavers. When whole blood was stored at 3 degrees C, Met-Hb reduction was observed in blood samples from nitrite-administered rats and in the blood from a victim poisoned by a weed killer containing some oxidant. When samples were stored at -30 degrees C, Met-Hb formation by autoxidation was inevitably observed in blood samples stored as whole blood, whereas addition of a cryoprotectant to whole blood could prevent Met-Hb formation in all the blood samples. When whole blood was stored at -80 degrees C or -196 degrees C, Met-Hb concentrations were practically stable until at least 30 days regardless of the initial values except in the control rat blood samples stored at -80 degrees C which showed slight formation of Met-Hb. From the results obtained, both the storage with a cryoprotectant at -30 degrees C and that without any additions at -80 degrees C or -196 degrees C proved to be suitable for long-term storage of blood samples from autopsy cadavers for Met-Hb determination.Entities:
Mesh:
Substances:
Year: 1990 PMID: 2335326 DOI: 10.1016/0379-0738(90)90229-r
Source DB: PubMed Journal: Forensic Sci Int ISSN: 0379-0738 Impact factor: 2.395