OBJECTIVES: The Monson's sphere and curve of Wilson can be used as reference for prosthetic reconstructions or orthodontic treatments. This study aimed to generate and measure the three-dimensional (3-D) Monson's sphere and curve of Wilson using virtual dental models and custom software. METHODS: Mandibular dental casts from 79 young adults of Korean descent were scanned and rendered as virtual dental models using a 3-D digitizing scanner. 26 landmarks were digitized on the virtual dental models using a custom made software program. The Monson's sphere was estimated by fitting a sphere to the cusp tips using a least-squares method. Two curves of Wilson were generated by finding the intersecting circle between the Monson's sphere and two vertical planes orthogonal to a virtual occlusal plane. Non-parametric Mann-Whitney and Kruskal-Wallis tests were performed to test for difference between sex and in cusp number within tooth position. RESULTS: The mean radius of Monson's sphere was 110.89 ± 25.75 mm. There were significant differences between males and females in all measurements taken (p<0.01), within 16.87-17.27 mm. Furthermore, morphological variation derived from variability in cusp number in the second premolar and second molar were not found to influence occlusal curvature (p>0.05). CONCLUSIONS: This study describes a best-fit algorithm for generating 3-D Monson's sphere using occlusal curves quantified from virtual dental models. The radius of Monson's sphere in Korean subjects was greater than the original four-inch value suggested by Monson. CLINICAL SIGNIFICANCE: The Monson's sphere and curve of Wilson can be used as a reference for prosthetic reconstruction and orthodontic treatment. The data found in this study may be applied to improve dental treatment results.
OBJECTIVES: The Monson's sphere and curve of Wilson can be used as reference for prosthetic reconstructions or orthodontic treatments. This study aimed to generate and measure the three-dimensional (3-D) Monson's sphere and curve of Wilson using virtual dental models and custom software. METHODS: Mandibular dental casts from 79 young adults of Korean descent were scanned and rendered as virtual dental models using a 3-D digitizing scanner. 26 landmarks were digitized on the virtual dental models using a custom made software program. The Monson's sphere was estimated by fitting a sphere to the cusp tips using a least-squares method. Two curves of Wilson were generated by finding the intersecting circle between the Monson's sphere and two vertical planes orthogonal to a virtual occlusal plane. Non-parametric Mann-Whitney and Kruskal-Wallis tests were performed to test for difference between sex and in cusp number within tooth position. RESULTS: The mean radius of Monson's sphere was 110.89 ± 25.75 mm. There were significant differences between males and females in all measurements taken (p<0.01), within 16.87-17.27 mm. Furthermore, morphological variation derived from variability in cusp number in the second premolar and second molar were not found to influence occlusal curvature (p>0.05). CONCLUSIONS: This study describes a best-fit algorithm for generating 3-D Monson's sphere using occlusal curves quantified from virtual dental models. The radius of Monson's sphere in Korean subjects was greater than the original four-inch value suggested by Monson. CLINICAL SIGNIFICANCE: The Monson's sphere and curve of Wilson can be used as a reference for prosthetic reconstruction and orthodontic treatment. The data found in this study may be applied to improve dental treatment results.
Authors: K Suresh Babu; A Nanda Kumar; Pradeep Babu Kommi; P Hari Krishnan; M Senthil Kumar; R Senkutvan Sabapathy; V Vijay Kumar Journal: J Clin Diagn Res Date: 2017-08-01