Literature DB >> 23353067

Making three-dimensional Monson's sphere using virtual dental models.

Shin-Eun Nam1, Young-Seok Park, WooCheol Lee, Sug-Joon Ahn, Seung-Pyo Lee.   

Abstract

OBJECTIVES: The Monson's sphere and curve of Wilson can be used as reference for prosthetic reconstructions or orthodontic treatments. This study aimed to generate and measure the three-dimensional (3-D) Monson's sphere and curve of Wilson using virtual dental models and custom software.
METHODS: Mandibular dental casts from 79 young adults of Korean descent were scanned and rendered as virtual dental models using a 3-D digitizing scanner. 26 landmarks were digitized on the virtual dental models using a custom made software program. The Monson's sphere was estimated by fitting a sphere to the cusp tips using a least-squares method. Two curves of Wilson were generated by finding the intersecting circle between the Monson's sphere and two vertical planes orthogonal to a virtual occlusal plane. Non-parametric Mann-Whitney and Kruskal-Wallis tests were performed to test for difference between sex and in cusp number within tooth position.
RESULTS: The mean radius of Monson's sphere was 110.89 ± 25.75 mm. There were significant differences between males and females in all measurements taken (p<0.01), within 16.87-17.27 mm. Furthermore, morphological variation derived from variability in cusp number in the second premolar and second molar were not found to influence occlusal curvature (p>0.05).
CONCLUSIONS: This study describes a best-fit algorithm for generating 3-D Monson's sphere using occlusal curves quantified from virtual dental models. The radius of Monson's sphere in Korean subjects was greater than the original four-inch value suggested by Monson. CLINICAL SIGNIFICANCE: The Monson's sphere and curve of Wilson can be used as a reference for prosthetic reconstruction and orthodontic treatment. The data found in this study may be applied to improve dental treatment results.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Mesh:

Year:  2013        PMID: 23353067     DOI: 10.1016/j.jdent.2013.01.003

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  3 in total

1.  Evaluating the Correlation between Anteroposterior and Mediolateral Compensatory Curves and their Influence on Dentoskeletal Morphology-An In vitro CBCT Study.

Authors:  K Suresh Babu; A Nanda Kumar; Pradeep Babu Kommi; P Hari Krishnan; M Senthil Kumar; R Senkutvan Sabapathy; V Vijay Kumar
Journal:  J Clin Diagn Res       Date:  2017-08-01

2.  Evaluation of the Relationship between Curve of Spee, WALA-FA Distance and Curve of Wilson in Normal Occlusion.

Authors:  Furkan Dindaroğlu; Gökhan Serhat Duran; Alaattin Tekeli; Serkan Görgülü; Servet Doğan
Journal:  Turk J Orthod       Date:  2016-12-01

3.  Comparison of Dental Stone Models and Their 3D Printed Acrylic Replicas for the Accuracy and Mechanical Properties.

Authors:  Marta Czajkowska; Ewa Walejewska; Łukasz Zadrożny; Monika Wieczorek; Wojciech Święszkowski; Leopold Wagner; Eitan Mijiritsky; Jarosław Markowski
Journal:  Materials (Basel)       Date:  2020-09-13       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.