Homogeneous high attenuation renal cysts and solid masses--differentiation with single phase dual energy computed tomography.

X l Liu1, J j Zhou, M S Zeng, Z p Ma, Y q Ding.   

Abstract

AIM: To assess the feasibility of using single-phase dual-energy computed tomography (DECT) to differentiate between homogeneous high attenuation renal cysts and solid renal masses.
MATERIALS AND METHODS: Twenty-nine pathologically proven solid renal masses in 29 patients and 14 high attenuation renal cysts from 11 patients were evaluated retrospectively. Two readers independently measured CT values from each lesion using both unenhanced single-energy phase and nephrographic dual-energy phase scans. Enhancement was defined as the attenuation difference between average-weighted 120 kV images and unenhanced images. Diagnostic sensitivity, specificity and accuracy based on enhancement, D-value (CT: 80 kV-140 kV) and DE-ratio (CT: 80/140 kV) were compared by the receiver operator characteristic (ROC) curves.
RESULTS: Using 17.6 HU as the cutoff value for enhancement, resulted in a sensitivity, specificity and accuracy of 96.6%, 100% and 97.7%, respectively. Corresponding values were 100%, 92.9% and 97.7% using a D-value cutoff of 15.6 HU, and 100%, 85.7% and 95.3% using a DE-ratio cutoff of 1.3. There were no significant differences in the AUCs obtained from the ROC curves for enhancement, D-value or DE-ratio. The mean effective radiation dose was 6.04 mSv with biphasic scanning compared with 2.91 mSv for single dual-energy nephrographic phase scanning.
CONCLUSION: Single-phase dual-energy CT is able to differentiate high attenuation renal cysts and solid renal masses with high sensitivity, specificity and accuracy, based on either D-value or DE-ratio. Omitting unenhanced scanning reduces the radiation dose by more than 50%.
Copyright © 2012 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23352763     DOI: 10.1016/j.crad.2012.11.008

Source DB:  PubMed          Journal:  Clin Radiol        ISSN: 0009-9260            Impact factor:   2.350


  3 in total

Review 1.  CT and MRI of small renal masses.

Authors:  Zhen J Wang; Antonio C Westphalen; Ronald J Zagoria
Journal:  Br J Radiol       Date:  2018-05-10       Impact factor: 3.039

2.  Renal cystic lesions characterization using spectral detector CT (SDCT): Added value of spectral results.

Authors:  Rivka Kessner; Nils Große Hokamp; Les Ciancibello; Nikhil Ramaiya; Karin A Herrmann
Journal:  Br J Radiol       Date:  2019-05-24       Impact factor: 3.039

3.  Diagnostic accuracy of contrast-enhanced computed tomography and contrast-enhanced magnetic resonance imaging of small renal masses in real practice: sensitivity and specificity according to subjective radiologic interpretation.

Authors:  Jae Heon Kim; Hwa Yeon Sun; Jiyoung Hwang; Seong Sook Hong; Yong Jin Cho; Seung Whan Doo; Won Jae Yang; Yun Seob Song
Journal:  World J Surg Oncol       Date:  2016-10-12       Impact factor: 2.754

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.