Literature DB >> 23351879

Use of bone graft substitutes in the management of tibial plateau fractures.

Thomas Goff1, Nikolaos K Kanakaris, Peter V Giannoudis.   

Abstract

The current available evidence for the use of bone graft substitutes in the management of subchondral bone defects associated with tibial plateau fractures as to their efficiency and safety has been collected following a literature review of the Ovid MEDLINE (1948-Present) and EMBASE (1980-Present). Nineteen studies were analysed reporting on 672 patients (674 fractures), with a mean age of 50.35 years (range 15-89), and a gender ratio of 3/2 males/females. The graft substitutes evaluated in the included studies were calcium phosphate cement, hydroxyapatite granules, calcium sulphate, bioactive glass, tricalcium phosphate, demineralised bone matrix, allografts, and xenograft. Fracture healing was uneventful in over 90% of the cases over a variant period of time. Besides two studies reporting on injectable calcium phosphate cement excellent incorporation was reported within 6 to 36 months post-surgery. No correlation was made by any of the authors between poor incorporation/resorption and adverse functional or radiological outcome. Secondary collapse of the knee joint surface ≥ 2 mm was reported in 8.6% in the biological substitutes (allograft, DBM, and xenograft), 5.4% in the hydroxyapatite, 3.7% in the calcium phosphate cement, and 11.1% in the calcium sulphate cases. The recorded incidence of primary surgical site and donor site infection (3.6%) was not statistically significant different, however donor site-related pain was reported up to 12 months following autologous iliac bone graft (AIBG) harvest. Shorter total operative time, greater tolerance of early weight bearing, improved early functional outcomes within the first year post-surgery was also recorded in the studies reporting on the use of injectable calcium phosphate cement (Norian SRS). Despite a lack of good quality randomised control trials, there is arguably sufficient evidence supporting the use of bone graft substitutes at the clinical setting of depressed plateau fractures.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23351879     DOI: 10.1016/S0020-1383(13)70019-6

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  26 in total

1.  Fixation augmentation using calcium-phosphate bone substitute improves outcomes of complex tibial plateau fractures. A matched, cohort study.

Authors:  Matthieu Ollivier; Yassine Bulaïd; Christophe Jacquet; Sebastien Pesenti; Jean-Noel Argenson; Sebastien Parratte
Journal:  Int Orthop       Date:  2018-04-07       Impact factor: 3.075

2.  The outcome after lateral tibial plateau fracture treated with percutaneus screw fixation show a tendency towards worse functional outcome compared with a reference population.

Authors:  R Elsoe; P Larsen; N Shekhrajka; L Ferreira; S E Ostgaard; S Rasmussen
Journal:  Eur J Trauma Emerg Surg       Date:  2015-02-13       Impact factor: 3.693

Review 3.  Safe clinical use of carbon nanotubes as innovative biomaterials.

Authors:  Naoto Saito; Hisao Haniu; Yuki Usui; Kaoru Aoki; Kazuo Hara; Seiji Takanashi; Masayuki Shimizu; Nobuyo Narita; Masanori Okamoto; Shinsuke Kobayashi; Hiroki Nomura; Hiroyuki Kato; Naoyuki Nishimura; Seiichi Taruta; Morinobu Endo
Journal:  Chem Rev       Date:  2014-04-10       Impact factor: 60.622

4.  Minimally invasive opening wedge tibia outpatient osteotomy, using screw-to-plate locking technique and a calcium phosphate cement.

Authors:  Claude Schwartz
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-01-10

Review 5.  Orthobiologics in the augmentation of osteoporotic fractures.

Authors:  J Tracy Watson; Daemeon A Nicolaou
Journal:  Curr Osteoporos Rep       Date:  2015-02       Impact factor: 5.096

6.  Bone substitutes and implantation depths for subchondral bone repair in osteochondral defects of porcine knee joints.

Authors:  Tomohiko Matsuo; Keisuke Kita; Tatsuo Mae; Yasukazu Yonetani; Satoshi Miyamoto; Hideki Yoshikawa; Ken Nakata
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-02-01       Impact factor: 4.342

7.  Autograft versus allograft reconstruction of acute tibial plateau fractures: a comparative study of complications and outcome.

Authors:  Abolfazl Bagherifard; Hassan Ghandhari; Mahmoud Jabalameli; Mohammad Rahbar; Hosseinali Hadi; Mehdi Moayedfar; Mohammadreza Minatour Sajadi; Alireza Karimpour
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-10-08

8.  Lateral tibial plateau fractures-functional outcomes and complications after open reduction and internal fixation.

Authors:  Sasa Milenkovic; Milan Mitkovic; Milorad Mitkovic; Predrag Stojiljkovic; Mladen Stojanovic
Journal:  Int Orthop       Date:  2020-08-01       Impact factor: 3.075

9.  Updates in biological therapies for knee injuries: bone.

Authors:  Mauricio Kfuri; Rafael Lara de Freitas; Bruno Bellaguarda Batista; Rodrigo Salim; Marcello Teixeira Castiglia; Ricardo Antonio Tavares; Paulo Henrique Araújo
Journal:  Curr Rev Musculoskelet Med       Date:  2014-09

10.  Settable polymer/ceramic composite bone grafts stabilize weight-bearing tibial plateau slot defects and integrate with host bone in an ovine model.

Authors:  Sichang Lu; Madison A P McGough; Stefanie M Shiels; Katarzyna J Zienkiewicz; Alyssa R Merkel; Joseph P Vanderburgh; Jeffry S Nyman; Julie A Sterling; David J Tennent; Joseph C Wenke; Scott A Guelcher
Journal:  Biomaterials       Date:  2018-06-26       Impact factor: 12.479

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.