Biomechanical evaluation of undersized drilling on implant biomechanical stability at early implantation times.

Paulo G Coelho1, Charles Marin, Hellen S Teixeira, Felipe E Campos, Julio B Gomes, Fernando Guastaldi, Rodolfo B Anchieta, Lucas Silveira, Estevam A Bonfante.   

Abstract

PURPOSE: The present study evaluated the effect of different drilling dimensions (undersized, regular, and oversized) in the insertion and removal torques of dental implants in a beagle dog model.
METHODS: Six beagle dogs were acquired and subjected to bilateral surgeries in the radii 1 and 3 weeks before euthanasia. During surgery, 3 implants, 4 mm in diameter by 10 mm in length, were placed in bone sites drilled to 3.2 mm, 3.5 mm, and 3.8 mm in final diameter. The insertion and removal torque was recorded for all samples. Statistical analysis was performed by paired t tests for repeated measures and by t tests assuming unequal variances (all at the 95% level of significance).
RESULTS: Overall, the insertion torque and removal torque levels obtained were inversely proportional to the drilling dimension, with a significant difference detected between the 3.2 mm and 3.5 mm relative to the 3.8 mm groups (P < 0.03). Although insertion torque-removal torque paired observations was statistically maintained for the 3.5 mm and 3.8 mm groups, a significant decrease in removal torque values relative to insertion torque levels was observed for the 3.2 mm group. A different pattern of healing and interfacial remodeling was observed for the different groups.
CONCLUSIONS: Different drilling dimensions resulted in variations in insertion torque values (primary stability) and stability maintenance over the first weeks of bone healing.
Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23351770     DOI: 10.1016/j.joms.2012.10.008

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  11 in total

1.  Evaluation of accuracy in implant site preparation performed in single- or multi-step drilling procedures.

Authors:  Nadine Marheineke; Uta Scherer; Martin Rücker; Constantin von See; Björn Rahlf; Nils-Claudius Gellrich; Marcus Stoetzer
Journal:  Clin Oral Investig       Date:  2017-12-17       Impact factor: 3.573

2.  Differences in crestal bone-to-implant contact following an under-drilling compared to an over-drilling protocol. A study in the rabbit tibia.

Authors:  Omer Cohen; Zeev Ormianer; Haim Tal; Daniel Rothamel; Miron Weinreb; Ofer Moses
Journal:  Clin Oral Investig       Date:  2016-03-02       Impact factor: 3.573

3.  Drilling dimension effects in early stages of osseointegration and implant stability in a canine model.

Authors:  Felipe-Eduardo Baires-Campos; Ryo Jimbo; Estevam-Augusto Bonfante; Maiolino-Thomaz Fonseca-Oliveira; Camila Moura; Darceny Zanetta-Barbosa; Paulo-Guilherme Coelho
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2015-07-01

4.  Effects of aspirin-loaded graphene oxide coating of a titanium surface on proliferation and osteogenic differentiation of MC3T3-E1 cells.

Authors:  Liping Ren; Shuang Pan; Haiqing Li; Yanping Li; Lina He; Shuang Zhang; Jingyi Che; Yumei Niu
Journal:  Sci Rep       Date:  2018-10-11       Impact factor: 4.379

Review 5.  Osseodensification - A novel approach in implant dentistry.

Authors:  Umesh Y Pai; Shobha J Rodrigues; Karishma S Talreja; Mahesh Mundathaje
Journal:  J Indian Prosthodont Soc       Date:  2018 Jul-Sep

6.  Evaluation of Insertion Energy as Novel Parameter for Dental Implant Stability.

Authors:  Tanja Grobecker-Karl; Anthony Dickinson; Siegfried Heckmann; Matthias Karl; Constanze Steiner
Journal:  J Clin Med       Date:  2020-09-15       Impact factor: 4.241

Review 7.  Stability of Dental Implants and Thickness of Cortical Bone: Clinical Research and Future Perspectives. A Systematic Review.

Authors:  Danilo Alessio Di Stefano; Paolo Arosio; Paolo Capparè; Silvia Barbon; Enrico Felice Gherlone
Journal:  Materials (Basel)       Date:  2021-11-25       Impact factor: 3.623

8.  The Effect of Coronal Implant Design and Drilling Protocol on Bone-to-Implant Contact: A 3-Month Study in the Minipig Calvarium.

Authors:  Omer Cohen; Dieter D Bosshardt; Evegeny Weinberg; Gil Slutzkey; Ofer Moses
Journal:  Materials (Basel)       Date:  2021-05-18       Impact factor: 3.623

9.  New Osseodensification Implant Site Preparation Method to Increase Bone Density in Low-Density Bone: In Vivo Evaluation in Sheep.

Authors:  Paolo Trisi; Marco Berardini; Antonello Falco; Michele Podaliri Vulpiani
Journal:  Implant Dent       Date:  2016-02       Impact factor: 2.454

10.  Combined effect of undersized surgical technique and axial compression on the primary implant stability and host bone architecture.

Authors:  Afsheen Tabassum; Gert J Meijer; Vincent M J I Cuijpers; X Frank Walboomers
Journal:  Saudi Dent J       Date:  2020-03-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.