OBJECTIVE: To assess if predefined variables in study design, instrument type, and patient characteristics account for variance in reported retest reliability for the Oswestry Disability Index (ODI) and Roland-Morris Questionnaire (RMQ). A second aim was a more precise estimate of instrument reliability. STUDY DESIGN AND
SETTING: A systematic literature search of MEDLINE, EMBASE, AMED, PsycINFO, and CINAHL was performed from inception to January 2011. Hand search, gray literature, and reference retrieval completed the search. Two blinded reviewers extracted the data. Original authors were contacted for the missing data. A meta-analysis was performed with the intraclass correlation coefficient as the outcome measure.
RESULTS: Fifty studies on 31 ODI and 28 RMQ cohorts were retrieved that met the inclusion criteria. Meta-analysis found the ODI more reliable than the RMQ (coefficient, -0.2840; P = 0.009) and lower reliability on increased days to retest (coefficient, -0.0089; P = 0.005) and in low back pain (LBP) with leg pain than LBP only cohorts (coefficient, -0.2194; P = 0.046). The use of a transition item to identify stable patients and percentage of cohort not included at retest were significant only on single variable analysis.
CONCLUSION: Study design and population influence the reliability of a given instrument, however, a greater difference in reliability exists between instruments.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23347850     DOI: 10.1016/j.jclinepi.2012.06.024

Source DB:  PubMed          Journal:  J Clin Epidemiol        ISSN: 0895-4356            Impact factor:   6.437


  3 in total

1.  Getting serious about test-retest reliability: a critique of retest research and some recommendations.

Authors:  Denise F Polit
Journal:  Qual Life Res       Date:  2014-02-07       Impact factor: 4.147

2.  Feasibility of using the patient-reported outcomes measurement information system in academic health centers: case series design on pain reduction after chiropractic care.

Authors:  Jeanmarie R Burke
Journal:  J Chiropr Med       Date:  2014-09

3.  Construct validity and responsiveness of commonly used patient reported outcome instruments in decompression for lumbar spinal stenosis.

Authors:  Karthik Vishwanathan; Ian Braithwaite
Journal:  J Clin Orthop Trauma       Date:  2021-01-13