Literature DB >> 23347687

Image guidance to improve reliability and data integrity of transcranial Doppler sonography.

Axel Neulen1, Christian Greke, Esther Prokesch, Jochem König, Daniel Wertheimer, Alf Giese.   

Abstract

BACKGROUND: Principles and accuracy of image-guided transcranial Doppler (IG TCD) sonography have been published recently. However, it remains open whether combination of image guidance and TCD offers an additional clinical advantage. This study scores the accuracy of conventional TCD examinations and investigates the potential improvement of TCD data integrity and reliability regarding the additional use of IG.
METHODS: Conventional TCD was performed by a group of experienced investigators, who were blinded to images of a navigation system tracking the Doppler probe, whereas an independent observer documented the TCD findings, acquired by the investigators, due to saving spatial data of the TCD sample volume using IG for subsequent analysis. In a second set of experiments, image guidance was available to investigators without any previous TCD experience.
RESULTS: The analysis of 3D data of vessels (n=173) labeled by experienced investigators in conventional TCD, revealed a rate of 37% misinterpreted Doppler signals regarding the target vessel. Correctness of labeling was comparable between the different vascular segments. The rate of correct labeling was higher for right- (69%) than for left-sided vessels (57%). In comparison, by using IG, TCD investigators without any previous TCD experience achieved a significantly lower rate of 10% (n=39) mislabeled vessels.
CONCLUSIONS: Our data suggest, that misinterpretation of the vascular source of the Doppler signal is a common source of errors in conventional TCD. Visualization of the vascular anatomy by image guidance offers improved accuracy and reliability of TCD results and may positively influence the learning curve for inexperienced investigators.
Copyright © 2013. Published by Elsevier B.V.

Entities:  

Keywords:  Acoustic window; Bone window; ICU; Image guidance; Neurointensive care; Neuronavigation; Neurovascular diseases; Sonothrombolysis; TCD; Transcranial Doppler sonography; Ultrasound; Vasospasm

Mesh:

Year:  2013        PMID: 23347687     DOI: 10.1016/j.clineuro.2012.12.025

Source DB:  PubMed          Journal:  Clin Neurol Neurosurg        ISSN: 0303-8467            Impact factor:   1.876


  2 in total

Review 1.  Brain ultrasonography: methodology, basic and advanced principles and clinical applications. A narrative review.

Authors:  Chiara Robba; Alberto Goffi; Thomas Geeraerts; Danilo Cardim; Gabriele Via; Marek Czosnyka; Soojin Park; Aarti Sarwal; Llewellyn Padayachy; Frank Rasulo; Giuseppe Citerio
Journal:  Intensive Care Med       Date:  2019-04-25       Impact factor: 17.440

2.  Safety and efficacy of a novel robotic transcranial doppler system in subarachnoid hemorrhage.

Authors:  Kevin Clare; Alan Stein; Nitesh Damodara; Eric Feldstein; Hussein Alshammari; Syed Ali; Christeena Kurian; Jon Rosenberg; Andrew Bauerschmidt; Gurmeen Kaur; Justin Santarelli; Robert Hamilton; Stephan Mayer; Chirag D Gandhi; Fawaz Al-Mufti
Journal:  Sci Rep       Date:  2022-02-10       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.