| Literature DB >> 23346191 |
Jianzi Wei1, Huijuan Mao, Yu Zhou, Lina Wang, Sheng Liu, Xueyong Shen.
Abstract
A highly sensitive volt-ampere characteristics detecting system was applied to measure the volt-ampere curves of nine acupuncture points, LU9, HT7, LI4, PC6, ST36, SP6, KI3, LR3, and SP3, and corresponding nonacupuncture points bilaterally from 42 healthy volunteers. Electric currents intensity was increased from 0 μA to 20 μA and then returned to 0 μA again. The results showed that the volt-ampere curves of acupuncture points had nonlinear property and magnetic hysteresis-like feature. On all acupuncture point spots, the volt-ampere areas of the increasing phase were significantly larger than that of the decreasing phase (P < 0.01). The volt-ampere areas of ten acupuncture point spots were significantly smaller than those of the corresponding nonacupuncture point spots when intensity was increase (P < 0.05 ~ P < 0.001). And when intensity was decrease, eleven acupuncture point spots showed the same property as above (P < 0.05 ~ P < 0.001), while two acupuncture point spots showed opposite phenomenon in which the areas of two acupuncture point spots were larger than those of the corresponding nonacupuncture point spots (P < 0.05 ~ P < 0.01). These results show that the phenomenon of low skin resistance does not exist to all acupuncture points.Entities:
Year: 2012 PMID: 23346191 PMCID: PMC3533649 DOI: 10.1155/2012/179657
Source DB: PubMed Journal: Evid Based Complement Alternat Med ISSN: 1741-427X Impact factor: 2.629
Figure 1Hardware schematic diagram of volt-ampere characteristic detection system. A highly sensitive volt-ampere characteristic detecting system was constructed using a single chip micyoco (SCM), a digital-analog component (DAC), a constant current source component (CCS), a voltage follower, an attenuator, an analog-digital component (ADC), and two electrodes. The detecting electrode was a plane electrode installed a silver head 4 mm in diameter. The negative electrode was silver-gilt like that of the limb lead of an electrocardiograph. The SCM was connected to the USB of a personal computer (PC) through a data line.
Figure 2Electrical current-time I-T curve of detecting system. The electrical current first increase from 0 μA to 20 μA (0–10 s), than decrease from 20 μA to 0 μA (10–20 s).
Figure 3Schematic diagram of volt-ampere curve of the acupuncture points.
Figure 4Volt-ampere curve of PC 6. The volt-ampere curves of acupuncture points were parabola-like rather than straight. The curves produced by increasing current intensity did not totally overlap those produced by decreasing current intensity.
Volt-ampere areas of acupuncture points at human bodies.
| Right increasing scan | Left increasing scan | Right decreasing scan | Left decreasing scan | ||
|---|---|---|---|---|---|
| LU9 | ( | 169.83 ± 104.30∗∗∗∗∧ | 172.82 ± 89.55∗∗∗∗∧ | 151.95 ± 77.63**** | 154.36 ± 66.58**** |
| Control point of LU9 | 249.27 ± 97.82∧ | 227.31 ± 103.34∧ | 218.89 ± 76.96 | 198.43 ± 74.39 | |
| HT7 | ( | 272.30 ± 113.63∧ | 245.28 ± 109.48∧ | 239.73 ± 88.99 | 217.69 ± 87.27 |
| Control point of HT7 | 277.38 ± 103.41∧ | 255.53 ± 94.83∧ | 238.10 ± 79.92 | 226.31 ± 70.41 | |
| LI4 | ( | 244.83 ± 106.56∧ | 244.40 ± 115.35∧ | 197.87 ± 71.71* | 191.88 ± 77.26 |
| Control point of LI4 | 226.53 ± 102.00∧ | 227.89 ± 111.78∧ | 178.56 ± 70.65 | 182.05 ± 76.23 | |
| PC6 | ( | 208.72 ± 112.58∗∗∧ | 190.58 ± 92.47∗∗∧∗ | 164.05 ± 79.60*** | 151.38 ± 60.60**** |
| Control point of PC6 | 231.81 ± 124.30∧ | 213.01 ± 97.60∧ | 183.09 ± 87.69 | 166.43 ± 64.45 | |
| ST36 | ( | 178.14 ± 89.23∗∗∗∗∧ | 186.57 ± 109.47∗∗∗∗∧ | 141.57 ± 61.71**** | 147.46 ± 72.01**** |
| Control point of ST36 | 221.76 ± 98.97∧ | 240.41 ± 124.20∧ | 172.61 ± 65.90 | 179.18 ± 82.20 | |
| SP6 | ( | 225.24 ± 104.14∗∗∗∧ | 231.55 ± 106.51∗∧ | 178.29 ± 75.88 | 179.91 ± 71.66** |
| Control point of SP6 | 258.02 ± 122.97∧ | 252.07 ± 114.07∧ | 188.38 ± 81.09 | 193.26 ± 73.30 | |
| KI3 | ( | 187.65 ± 116.88∗∗∗∗∧ | 209.78 ± 114.49∗∧ | 157.43 ± 81.57**** | 169.14 ± 79.60** |
| Control point of KI3 | 257.00 ± 146.53∧ | 262.43 ± 134.84∧ | 213.14 ± 112.28 | 212.54 ± 90.84 | |
| LR3 | ( | 212.60 ± 100.70∧ | 220.67 ± 103.65∧ | 177.58 ± 69.11** | 180.98 ± 68.45*** |
| Control point of LR3 and SP3 | 227.19 ± 104.57∧ | 245.27 ± 95.29∧ | 197.35 ± 73.69 | 211.21 ± 65.99 | |
| SP3 | 247.47 ± 100.95∧ | 252.68 ± 90.14∧ | 229.31 ± 82.53*** | 228.73 ± 70.15 |
Compare to decreasing-scan P < 0.01.
Compare to control point *P < 0.05; **P < 0.01; ***P < 0.005; ****P < 0.0001.