Literature DB >> 23345184

Use of centrifugal left ventricular assist device as a bridge to candidacy in severe heart failure with secondary pulmonary hypertension.

Ramesh S Kutty1, Jayan Parameshwar, Clive Lewis, Pedro A Catarino, Catherine D Sudarshan, David P Jenkins, John J Dunning, Steven S Tsui.   

Abstract

OBJECTIVES: Raised pulmonary artery pressure (PAP), trans-pulmonary gradient (TPG) and pulmonary vascular resistance (PVR) are risk factors for poor outcomes after heart transplant in patients with secondary pulmonary hypertension (PH) and may contraindicate transplant. Unloading of the left ventricle with an implantable left ventricular assist device (LVAD) may reverse these pulmonary vascular changes. We studied the effect of implanting centrifugal LVADs in a cohort of patients with secondary PH as a bridge to candidacy.
METHODS: Pulmonary haemodynamics on patients implanted with centrifugal LVADs at a single unit between May 2005 and December 2010 were retrospectively reviewed.
RESULTS: Twenty-nine patients were implanted with centrifugal LVADs (eight HeartWare ventricular assist device (HVAD), HeartWare International, USA and 21 VentrAssist, Ventracor Ltd., Australia). Seventeen were ineligible for transplant by virtue of high TPG/PVR. All the patients were optimized with inotrope/balloon pump followed by LVAD insertion. Four required temporary right VAD support. Thirty-day mortality post-LVAD was 3.4% (1 of 29) with a 1-year survival of 85.7% (24 of 28). Thirteen patients have been transplanted to date: 30-day mortality was 7.7% (1 of 13) and 1-year survival was 91% (10 of 11). Baseline and post-VAD pulmonary haemodynamics were significantly improved: systolic PAP (mmHg), mean PAP, TPG (mmHg) of 57 ± 9.5, 42 ± 4.4 and 14 ± 3.9 reduced to 32 ± 7.5, 18 ± 5.5 and 9 ± 3.3, respectively. PVR reduced from 5 ± 1.5 to 2.1 ± 0.5 Wood units (P < 0.05).
CONCLUSIONS: In selected heart failure patients with secondary PH, use of centrifugal LVAD results in significant reductions in PAP, TPG and PVR, which are observed within 1 month, reaching a nadir by 3 months. Such patients bridged to candidacy have post-transplant survival comparable with those having a heart transplant as primary treatment.

Entities:  

Keywords:  Bridge to candidacy; Centrifugal; Heart transplant; Pulmonary hypertension; Ventricular assist device

Mesh:

Year:  2013        PMID: 23345184     DOI: 10.1093/ejcts/ezs678

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  19 in total

Review 1.  Treatment and Prognosis of Pulmonary Hypertension in the Left Ventricular Assist Device Patient.

Authors:  Christopher W Jensen; Andrew B Goldstone; Y Joseph Woo
Journal:  Curr Heart Fail Rep       Date:  2016-06

Review 2.  Current status of the implantable LVAD.

Authors:  Sagar Kadakia; Ryan Moore; Vishnu Ambur; Yoshiya Toyoda
Journal:  Gen Thorac Cardiovasc Surg       Date:  2016-06-06

Review 3.  Pulmonary Hypertension in Heart Failure Patients: Pathophysiology and Prognostic Implications.

Authors:  Marco Guazzi; Valentina Labate
Journal:  Curr Heart Fail Rep       Date:  2016-12

Review 4.  Management of pulmonary hypertension from left heart disease in candidates for orthotopic heart transplantation.

Authors:  Anna Koulova; Alan L Gass; Saikrishna Patibandla; Chhaya Aggarwal Gupta; Wilbert S Aronow; Gregg M Lanier
Journal:  J Thorac Dis       Date:  2017-08       Impact factor: 2.895

5.  Long-term continuous-flow left ventricular assist devices (LVAD) as bridge to heart transplantation.

Authors:  Matteo Pozzi; Raphaël Giraud; Piergiorgio Tozzi; Karim Bendjelid; Jacques Robin; Philippe Meyer; Jean François Obadia; Carlo Banfi
Journal:  J Thorac Dis       Date:  2015-03       Impact factor: 2.895

Review 6.  Clinical implications of hemodynamic assessment during left ventricular assist device therapy.

Authors:  Teruhiko Imamura; Ben Chung; Ann Nguyen; Gabriel Sayer; Nir Uriel
Journal:  J Cardiol       Date:  2017-12-26       Impact factor: 3.159

7.  How to cope with a temporarily aborted transplant program: solutions for a prolonged waiting period.

Authors:  Frédéric Vanden Eynden; Martine Antoine; Bachar El Oumeiri; Marie-Luce Chirade; Jean-Luc Vachiéry; Guido J Van Nooten
Journal:  Ann Transl Med       Date:  2015-11

Review 8.  Pulmonary Hypertension in the Era of Mechanical Circulatory Support.

Authors:  Yamini Krishnamurthy; Lauren B Cooper; Kishan S Parikh; G Michael Felker; Carmelo A Milano; Joseph G Rogers; Adrian F Hernandez; Chetan B Patel
Journal:  ASAIO J       Date:  2016 Sep-Oct       Impact factor: 2.872

Review 9.  Pulmonary Hypertension Due to Left Ventricular Cardiomyopathy: Is it the Result or Cause of Disease Progression?

Authors:  Srinath Adusumalli; Jeremy A Mazurek
Journal:  Curr Heart Fail Rep       Date:  2017-12

Review 10.  Mechanical Circulatory Support for Decompensated Heart Failure.

Authors:  Tarique Al Musa; Colin Dominic Chue; Hoong Sern Lim
Journal:  Curr Heart Fail Rep       Date:  2017-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.