Free breathing real-time cardiac cine imaging with improved spatial resolution at 3 T.

Felix Schwab1, Florian Schwarz, Olaf Dietrich, Titus Lanz, Frank Resmer, Tobias Wichmann, Bernd J Wintersperger, Fabian Bamberg, Konstantin Nikolaou, Maximilian Reiser, Daniel Theisen.   

Abstract

OBJECTIVES: The aim of this study was to evaluate free-breathing single-shot real-time cine imaging for functional cardiac imaging at 3 T with increased spatial resolution. Special emphasis of this study was placed on the influence of parallel imaging techniques.
MATERIALS AND METHODS: Gradient echo phantom images were acquired with GRAPPA and modified SENSE reconstruction using both integrated and separate reference scans as well as TGRAPPA and TSENSE. In vivo measurements were performed for GRAPPA reconstruction with an integrated and a separate reference scan, as well as TGRAPPA using balanced steady-state free precession protocols. Three clinical protocols, rtLRInt (Tres = 51.3 milliseconds; voxel, 2.5 × 5.0 × 10 mm³), rtMRSep (Tres = 48.8 milliseconds; voxel, 1.9 × 3.1 × 10 mm³), and rtHRSep (Tres = 48.3 milliseconds; voxel, 1.6 × 2.6 × 10 mm), were investigated on 20 volunteers using GRAPPA reconstruction with internal as well as separate reference scans. End-diastolic volume, end-systolic volume, ejection fraction, peak ejection rate, peak filling rate, and myocardial mass were evaluated for the left ventricle and compared with an electrocardiogram-triggered segmented readout cine protocol used as standard of reference. All studies were performed at 3 T.
RESULTS: Phantom and in vivo data demonstrate that the combination of GRAPPA reconstruction with a separate reference scan provides an optimal compromise of image quality as well as spatial and temporal resolution. Functional values (P values) for the standard of reference, rtLRInt, rtMRSep, and rtHRSep end-diastolic volume were 141 ± 24 mL, 138 ± 21 mL, 138 ± 19 mL, and 128 ± 33 mL, respectively (P = 0.7, 0.7, 0.4); end-systolic volume, 55 ± 15 mL, 61 ± 14 mL, 58 ± 12 mL, and 55 ± 20 mL, respectively (P = 0.23, 0.43, 0.62); ejection fraction, 61% ± 5%, 57% ± 5%, 58% ± 4%, and 56% ± 8%, respectively (P = 0.01, 0.11, 0.06); peak ejection rate, 481 ± 73 mL/s, 425 ± 62 mL/s, 434 ± 67 mL/s, and 381 ± 86 mL/s, respectively (P = 0.03, 0.04, 0.01); peak filling rate, 555 ± 80 mL/s, 480 ± 70 mL/s, 500 ± 70 mL/s, and 438 ± 108 mL/s, respectively (P= 0.007, 0.05, 0.004); and myocardial mass, 137 ± 26 g, 141 ± 25 g, 141 ± 23 g, and 130 ± 31 g, respectively (P = 0.62, 0.54, 0.99).
CONCLUSIONS: Using a separate reference scan and high acceleration factors up to R = 6, single-shot real-time cardiac imaging offers adequate temporal and spatial resolution for accurate assessment of global left ventricular function in free breathing with short examination times.

Entities:  

Mesh:

Year:  2013        PMID: 23344515     DOI: 10.1097/RLI.0b013e31827f1b68

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  5 in total

Review 1.  Recent advances in parallel imaging for MRI.

Authors:  Jesse Hamilton; Dominique Franson; Nicole Seiberlich
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2017-05-02       Impact factor: 9.795

2.  Single-Breath-Hold Evaluation of Cardiac Function with Use of Time-Resolved Parallel Cardiac Magnetic Resonance.

Authors:  Patrick Krumm; Jonas D Keuler; Stefanie Mangold; Tanja Zitzelsberger; Christer A Ruff; Bernhard D Klumpp; Petros Martirosian; Konstantin Nikolaou; Christof Burgstahler; Ulrich Kramer
Journal:  Tex Heart Inst J       Date:  2017-08-01

3.  Optimization of through-time radial GRAPPA with coil compression and weight sharing.

Authors:  James Ahad; Evan Cummings; Dominique Franson; Jesse Hamilton; Nicole Seiberlich
Journal:  Magn Reson Med       Date:  2022-04-15       Impact factor: 3.737

4.  Retrospective Electrocardiography-Gated Real-Time Cardiac Cine MRI at 3T: Comparison with Conventional Segmented Cine MRI.

Authors:  Chen Cui; Gang Yin; Minjie Lu; Xiuyu Chen; Sainan Cheng; Lu Li; Weipeng Yan; Yanyan Song; Sanjay Prasad; Yan Zhang; Shihua Zhao
Journal:  Korean J Radiol       Date:  2018-12-27       Impact factor: 3.500

5.  Real-Time Spiral CMR Is Superior to Conventional Segmented Cine-Imaging for Left-Ventricular Functional Assessment in Patients with Arrhythmia.

Authors:  Nicoleta Nita; Johannes Kersten; Alexander Pott; Fabian Weber; Temsgen Tesfay; Marius-Tudor Benea; Patrick Metze; Hao Li; Wolfgang Rottbauer; Volker Rasche; Dominik Buckert
Journal:  J Clin Med       Date:  2022-04-08       Impact factor: 4.241

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.