Literature DB >> 23342356

Effect of various putty-wash impression techniques on marginal fit of cast crowns.

Joseph Nissan1, Ofir Rosner, Mohammed Amin Bukhari, Oded Ghelfan, Raphael Pilo.   

Abstract

Marginal fit is an important clinical factor that affects restoration longevity. The accuracy of three polyvinyl siloxane putty-wash impression techniques was compared by marginal fit assessment using the nondestructive method. A stainless steel master cast containing three abutments with three metal crowns matching the three preparations was used to make 45 impressions: group A = single-step technique (putty and wash impression materials used simultaneously), group B = two-step technique with a 2-mm relief (putty as a preliminary impression to create a 2-mm wash space followed by the wash stage), and group C = two-step technique with a polyethylene spacer (plastic spacer used with the putty impression followed by the wash stage). Accuracy was assessed using a toolmaker microscope to measure and compare the marginal gaps between each crown and finish line on the duplicated stone casts. Each abutment was further measured at the mesial, buccal, and distal aspects. One-way analysis of variance was used for statistical analysis. P values and Scheffe post hoc contrasts were calculated. Significance was determined at .05. One-way analysis of variance showed significant differences among the three impression techniques in all three abutments and at all three locations (P < .001). Group B yielded dies with minimal gaps compared to groups A and C. The two-step impression technique with 2-mm relief was the most accurate regarding the crucial clinical factor of marginal fit.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23342356     DOI: 10.11607/prd.0713

Source DB:  PubMed          Journal:  Int J Periodontics Restorative Dent        ISSN: 0198-7569            Impact factor:   1.840


  4 in total

1.  Impression Techniques Used for Single-Unit Crowns: Findings from the National Dental Practice-Based Research Network.

Authors:  Michael S McCracken; David R Louis; Mark S Litaker; Helena M Minyé; Thomas Oates; Valeria V Gordan; Don G Marshall; Cyril Meyerowitz; Gregg H Gilbert
Journal:  J Prosthodont       Date:  2017-01-11       Impact factor: 2.752

2.  Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique.

Authors:  Marie-Hélène Pastoret; Gabriel Krastl; Julia Bühler; Roland Weiger; Nicola Ursula Zitzmann
Journal:  J Adv Prosthodont       Date:  2017-08-16       Impact factor: 1.904

3.  Effect of Storage Time and Temperature on Dimensional Stability of Impressions Made with Zinc Oxide Impression Paste.

Authors:  Sareh Habibzadeh; Shima Safaeian; Marjan Behruzibakhsh; Parisa Kaviyani; Mohamadjavad Kharazifard
Journal:  J Dent (Tehran)       Date:  2016-06

4.  Trueness of CAD/CAM digitization with a desktop scanner - an in vitro study.

Authors:  G Joós-Kovács; B Vecsei; Sz Körmendi; V A Gyarmathy; J Borbély; P Hermann
Journal:  BMC Oral Health       Date:  2019-12-12       Impact factor: 2.757

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.