Literature DB >> 23342188

Bypass surgery in limb salvage: polytetrafluoroethylene prosthetic bypass.

Joseph J Naoum1, Elias J Arbid.   

Abstract

Polytetrafluoroethylene (PTFE) grafts have proven to be an adequate alternative conduit for peripheral bypass operations. Whether or not one uses PTFE depends on several factors: surgeon preference, individual patient circumstances, or when autologous greater saphenous vein is not available or adequate. These conventional grafts have evolved and undergone modification. The intraluminal surface has been coated with carbon or bonded with heparin. The structure of grafts has been modified with the creation of a hood or cuff, with the incorporation of a stent-graft segment for a sutureless anastomosis, or the fusion of PTFE with an outer polyester layer to minimize suture hole bleeding. This evolution intends to limit graft thrombogenicity, ameliorate the formation of intimal hyperplasia, decrease complications, and improve overall graft patency.

Entities:  

Keywords:  autologous greater saphenous vein (AGSV); critical limb ischemia; graft patency; heparin-bonded PTFE; peripheral arterial bypass graft; polytetrafluoroethylene (PTFE) graft

Mesh:

Substances:

Year:  2012        PMID: 23342188      PMCID: PMC3549650          DOI: 10.14797/mdcj-8-4-43

Source DB:  PubMed          Journal:  Methodist Debakey Cardiovasc J        ISSN: 1947-6108


  20 in total

1.  ViPS (Viabahn Padova Sutureless) technique: preliminary results in the treatment of peripheral arterial disease.

Authors:  Luca Ferretto; Michele Piazza; Stefano Bonvini; Piero Battocchio; Franco Grego; Joseph J Ricotta
Journal:  Ann Vasc Surg       Date:  2011-10-22       Impact factor: 1.466

2.  Complementary distal arteriovenous fistula and deep vein interposition: a five-year experience with a new technique to improve infrapopliteal prosthetic bypass patency.

Authors:  E Ascer; M Gennaro; R M Pollina; M Ivanov; W R Yorkovich; M Ivanov; E Lorensen
Journal:  J Vasc Surg       Date:  1996-07       Impact factor: 4.268

3.  Saphenous vein or PTFE for femoropopliteal bypass. A prospective randomized trial.

Authors:  H W Tilanus; H Obertop; H Van Urk
Journal:  Ann Surg       Date:  1985-12       Impact factor: 12.969

4.  A comparative evaluation of polytetrafluoroethylene, umbilical vein, and saphenous vein bypass grafts for femoral-popliteal above-knee revascularization: a prospective randomized Department of Veterans Affairs cooperative study.

Authors:  W C Johnson; K K Lee
Journal:  J Vasc Surg       Date:  2000-08       Impact factor: 4.268

5.  Femoral-infrapopliteal bypass with prosthetic grafts.

Authors:  M J Eagleton; K Ouriel; C Shortell; R M Green
Journal:  Surgery       Date:  1999-10       Impact factor: 3.982

6.  Heparin-bonded grafts induce platelet aggregation in the presence of heparin-associated antiplatelet antibodies.

Authors:  J I Almeida; T K Liem; D Silver
Journal:  J Vasc Surg       Date:  1998-05       Impact factor: 4.268

7.  Below-knee bypass for limb salvage. Comparison of autogenous saphenous vein, polytetrafluoroethylene, and composite dacron-autogenous vein grafts.

Authors:  R W Hobson; J A O'Donnell; Z Jamil; K Mehta
Journal:  Arch Surg       Date:  1980-07

8.  Failure of arteriovenous fistulas at distal tibial bypass anastomotic sites.

Authors:  S O Snyder; J R Wheeler; R T Gregory; R G Gayle
Journal:  J Cardiovasc Surg (Torino)       Date:  1985 Mar-Apr       Impact factor: 1.888

9.  Randomized clinical trial of distal anastomotic interposition vein cuff in infrainguinal polytetrafluoroethylene bypass grafting.

Authors:  G D Griffiths; J Nagy; D Black; P A Stonebridge
Journal:  Br J Surg       Date:  2004-05       Impact factor: 6.939

10.  Randomization of autogenous vein and polytetrafluorethylene grafts in femoral-distal reconstruction.

Authors:  J J Bergan; F J Veith; V M Bernhard; J S Yao; W R Flinn; S K Gupta; L A Scher; R H Samson; J B Towne
Journal:  Surgery       Date:  1982-12       Impact factor: 3.982

View more
  4 in total

1.  The use of polytetrafluoroethylene graft for damaged renal artery in ABO-incompatible living donor kidney transplantation: a case report.

Authors:  Won-Bae Chang; Young-Heun Shin; Hyung Sub Park; Dong-Hwan Kim; Taeseung Lee
Journal:  Korean J Transplant       Date:  2022-03-31

2.  Dynamic Luminal Topography: A Potential Strategy to Prevent Vascular Graft Thrombosis.

Authors:  Nandan N Nath; Luka Pocivavsek; Joseph A Pugar; Ya Gao; Karim Salem; Nandan Pitre; Ryan McEnaney; Sachin Velankar; Edith Tzeng
Journal:  Front Bioeng Biotechnol       Date:  2020-08-31

Review 3.  Clinical results of biologic prosthesis: A systematic review and meta-analysis of comparative studies.

Authors:  Chumpon Wilasrusmee; Boonying Siribumrungwong; Suthas Horsirimanont; Napaphat Poprom; Jakrapan Jirasiritham; Ammarin Thakkinstian
Journal:  Ann Med Surg (Lond)       Date:  2017-01-25

4.  Intercondylar Route of Prosthetic Infragenicular Femoropopliteal Bypass Has Better Primary, Assisted, and Secondary Patency but Not Limb Salvage Rate Compared to the Medial Route.

Authors:  Tomas Grus; Lukas Lambert; Rohan Banerjee; Gabriela Grusova; Vilem Rohn; Tomas Vidim; Petr Mitas
Journal:  Biomed Res Int       Date:  2016-09-07       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.