Literature DB >> 23341147

Differences in tissue characterization of restenotic neointima between sirolimus-eluting stent and bare-metal stent: integrated backscatter intravascular ultrasound analysis for in-stent restenosis.

Hirohiko Ando1, Tetsuya Amano, Hiroaki Takashima, Kazuhiro Harada, Katsuhide Kitagawa, Akihiro Suzuki, Ayako Kunimura, Yusaku Shimbo, Ken Harada, Tomohiro Yoshida, Bunichi Kato, Tadayuki Uetani, Masataka Kato, Tatsuaki Matsubara, Soichiro Kumagai, Daiji Yoshikawa, Satoshi Isobe, Hideki Ishii, Toyoaki Murohara.   

Abstract

AIMS: The pathogenesis of in-stent restenosis (ISR) after drug-eluting stent (DES) implantation remains unclear. The purpose of this study is to analyse tissue characterizations of neointima in restenosis lesions after sirolimus-eluting stent (SES), comparing with those after bare metal stent (BMS) using integrated backscatter intravascular ultrasound (IB-IVUS). METHODS AND
RESULTS: A total of 54 consecutive patients who had ISR lesions after SES (n = 20) or BMS (n = 34) implantation were enrolled. For tissue characterization of neointima, IB-IVUS was performed by cross-sectional (at the minimum lumen area) and volumetric (within the stented segment) analyses. In addition, angiographic patterns of restenosis were evaluated with division into focal and diffuse. The focal angiographic pattern of restenosis was predominantly observed in the SES group (SES vs. BMS; 80.0 vs. 26.5%; P = 0.0001), whereas the diffuse pattern was more common in the BMS group (SES vs. BMS; 20.0 vs. 73.5%; P = 0.0001). On both cross-sectional and volumetric IB-IVUS analyses, the neointimal tissue in restenosis lesions after SES implantation had a significantly larger percentage of lipid tissue (cross-sectional: 23.3 ± 12.7 vs. 15.7 ± 11.9%; P = 0.033; volumetric: 22.8 ± 10.4 vs. 16.3 ± 7.0%; P = 0.008) and a significantly smaller percentage of fibrous tissue compared with that after BMS implantation (cross-sectional: 73.6 ± 11.6 vs. 82.0 ± 11.2%; P = 0.011, volumetric: 73.8 ± 9.5 vs. 80.5 ± 6.7%; P = 0.004).
CONCLUSION: This IB-IVUS study indicates that larger amounts of lipid tissue are present in neointima of SES when compared with BMS, suggesting that neoatherosclerosis may in part be responsible for ISR after SES implantation.

Entities:  

Keywords:  Atherosclerotic neointima; Restenosis; Sirolimus-eluting stent

Mesh:

Substances:

Year:  2013        PMID: 23341147     DOI: 10.1093/ehjci/jet003

Source DB:  PubMed          Journal:  Eur Heart J Cardiovasc Imaging        ISSN: 2047-2404            Impact factor:   6.875


  8 in total

1.  Tissue characteristics of neointima in late restenosis: integrated backscatter intravascular ultrasound analysis for in-stent restenosis.

Authors:  Hirohiko Ando; Akihiro Suzuki; Shinichiro Sakurai; Soichiro Kumagai; Akiyoshi Kurita; Katsuhisa Waseda; Hiroaki Takashima; Tetsuya Amano
Journal:  Heart Vessels       Date:  2016-10-11       Impact factor: 2.037

Review 2.  Neoatherosclerosis: Coronary stents seal atherosclerotic lesions but result in making a new problem of atherosclerosis.

Authors:  Hidenori Komiyama; Masamichi Takano; Noritake Hata; Yoshihiko Seino; Wataru Shimizu; Kyoichi Mizuno
Journal:  World J Cardiol       Date:  2015-11-26

3.  The impact of antiplatelet therapy on patients with vasospastic angina: A multicenter registry study of the Japanese Coronary Spasm Association.

Authors:  Hiroyoshi Mori; Jun Takahashi; Koichi Sato; Satoshi Miyata; Yusuke Takagi; Ryusuke Tsunoda; Tetsuya Sumiyoshi; Motoyuki Matsui; Yasuhiko Tanabe; Shozo Sueda; Shinichi Momomura; Koichi Kaikita; Satoshi Yasuda; Hisao Ogawa; Hiroaki Shimokawa; Hiroshi Suzuki
Journal:  Int J Cardiol Heart Vasc       Date:  2020-06-09

Review 4.  Vascular Wall Reactions to Coronary Stents-Clinical Implications for Stent Failure.

Authors:  Tommaso Gori
Journal:  Life (Basel)       Date:  2021-01-17

5.  The Predictive Value of Monocyte Count to High-Density Lipoprotein Cholesterol Ratio in Restenosis After Drug-Eluting Stent Implantation.

Authors:  Jing Nan; Shuai Meng; Hongyu Hu; Ruofei Jia; Ce Chen; Jianjun Peng; Zening Jin
Journal:  Int J Gen Med       Date:  2020-11-25

Review 6.  Neoatherosclerosis after Drug-Eluting Stent Implantation: Roles and Mechanisms.

Authors:  Yuanyuan Cui; Yue Liu; Fuhai Zhao; Dazhuo Shi; Keji Chen
Journal:  Oxid Med Cell Longev       Date:  2016-06-30       Impact factor: 6.543

7.  Optical coherence tomographic analysis of drug-eluting in-stent restenosis at different times: A STROBE compliant study.

Authors:  Chunguang Feng; Peiying Zhang; Bing Han; Xianchi Li; Yi Liu; Dongdong Niu; Yibing Shi
Journal:  Medicine (Baltimore)       Date:  2018-08       Impact factor: 1.817

Review 8.  In Stent Neo-Atherosclerosis: Pathophysiology, Clinical Implications, Prevention, and Therapeutic Approaches.

Authors:  Annunziata Nusca; Michele Mattia Viscusi; Francesco Piccirillo; Aurelio De Filippis; Antonio Nenna; Cristiano Spadaccio; Francesco Nappi; Camilla Chello; Fabio Mangiacapra; Francesco Grigioni; Massimo Chello; Gian Paolo Ussia
Journal:  Life (Basel)       Date:  2022-03-08
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.