Literature DB >> 23340114

Physiological responses of medical team members to a simulated emergency in tropical field conditions.

Matt B Brearley1, Michael F Heaney, Ian N Norton.   

Abstract

INTRODUCTION: Responses to physical activity while wearing personal protective equipment in hot laboratory conditions are well documented. However less is known of medical professionals responding to an emergency in hot field conditions in standard attire. Therefore, the purpose of this study was to assess the physiological responses of medical responders to a simulated field emergency in tropical conditions.
METHODS: Ten subjects, all of whom were chronically heat-acclimatized health care workers, volunteered to participate in this investigation. Participants were the medical response team of a simulated field emergency conducted at the Northern Territory Emergency Services training grounds, Yarrawonga, NT, Australia. The exercise consisted of setting up a field hospital, transporting patients by stretcher to the hospital, triaging and treating the patients while dressed in standard medical response uniforms in field conditions (mean ambient temperature of 29.3°C and relative humidity of 50.3%, apparent temperature of 27.9°C) for a duration of 150 minutes. Gastrointestinal temperature was transmitted from an ingestible sensor and used as the index of core temperature. An integrated physiological monitoring device worn by each participant measured and logged heart rate, chest temperature and gastrointestinal temperature throughout the exercise. Hydration status was assessed by monitoring the change between pre- and post-exercise body mass and urine specific gravity (USG).
RESULTS: Mean core body temperature rose from 37.5°C at the commencement of the exercise to peak at 37.8°C after 75 minutes. The individual peak core body temperature was 38.5°C, with three subjects exceeding 38.0°C. Subjects sweated 0.54 L per hour and consumed 0.36 L of fluid per hour, resulting in overall dehydration of 0.7% of body mass at the cessation of exercise. Physiological strain index was indicative of little to low strain.
CONCLUSIONS: The combination of the unseasonably mild environmental conditions and moderate work rates resulted in minimal heat storage during the simulated exercise. As a result, low sweat rates manifested in minimal dehydration. When provided with access to fluids in mild environmental conditions, chronically heat-acclimatized medical responders can meet their hydration requirements through ad libitum fluid consumption. Whether such an observation is replicated under a harsher thermal load remains to be investigated.

Entities:  

Mesh:

Year:  2013        PMID: 23340114     DOI: 10.1017/S1049023X12001847

Source DB:  PubMed          Journal:  Prehosp Disaster Med        ISSN: 1049-023X            Impact factor:   2.040


  11 in total

1.  Association Between Work-Related Hyperthermia Emergency Department Visits and Ambient Heat in Five Southeastern States, 2010-2012-A Case-Crossover Study.

Authors:  Jeffrey Shire; Ambarish Vaidyanathan; Michelle Lackovic; Terry Bunn
Journal:  Geohealth       Date:  2020-08-16

2.  Towards Investigating Global Warming Impact on Human Health Using Derivatives of Photoplethysmogram Signals.

Authors:  Mohamed Elgendi; Ian Norton; Matt Brearley; Richard R Fletcher; Derek Abbott; Nigel H Lovell; Dale Schuurmans
Journal:  Int J Environ Res Public Health       Date:  2015-10-14       Impact factor: 3.390

Review 3.  Occupational heat stress in Australian workplaces.

Authors:  Ollie Jay; John R Brotherhood
Journal:  Temperature (Austin)       Date:  2016-07-27

4.  On Time Domain Analysis of Photoplethysmogram Signals for Monitoring Heat Stress.

Authors:  Mohamed Elgendi; Rich Fletcher; Ian Norton; Matt Brearley; Derek Abbott; Nigel H Lovell; Dale Schuurmans
Journal:  Sensors (Basel)       Date:  2015-09-25       Impact factor: 3.576

5.  Influence of Chronic Heat Acclimatization on Occupational Thermal Strain in Tropical Field Conditions.

Authors:  Matt B Brearley; Ian Norton; Daryl Rush; Michael Hutton; Steve Smith; Linda Ward; Hector Fuentes
Journal:  J Occup Environ Med       Date:  2016-12       Impact factor: 2.162

6.  Optimal Signal Quality Index for Photoplethysmogram Signals.

Authors:  Mohamed Elgendi
Journal:  Bioengineering (Basel)       Date:  2016-09-22

7.  The Case for Heat Acclimatization of Disaster Responders-An Australian Perspective.

Authors:  Matt B Brearley; Ian N Norton; Abigail S Trewin
Journal:  Front Public Health       Date:  2017-04-25

8.  Incorporating health workers' perspectives into a WHO guideline on personal protective equipment developed during an Ebola virus disease outbreak.

Authors:  Saskia Den Boon; Constanza Vallenas; Mauricio Ferri; Susan L Norris
Journal:  F1000Res       Date:  2018-01-11

9.  Systolic peak detection in acceleration photoplethysmograms measured from emergency responders in tropical conditions.

Authors:  Mohamed Elgendi; Ian Norton; Matt Brearley; Derek Abbott; Dale Schuurmans
Journal:  PLoS One       Date:  2013-10-22       Impact factor: 3.240

Review 10.  Ebola virus disease and critical illness.

Authors:  Aleksandra Leligdowicz; William A Fischer; Timothy M Uyeki; Thomas E Fletcher; Neill K J Adhikari; Gina Portella; Francois Lamontagne; Christophe Clement; Shevin T Jacob; Lewis Rubinson; Abel Vanderschuren; Jan Hajek; Srinivas Murthy; Mauricio Ferri; Ian Crozier; Elhadj Ibrahima; Marie-Claire Lamah; John S Schieffelin; David Brett-Major; Daniel G Bausch; Nikki Shindo; Adrienne K Chan; Tim O'Dempsey; Sharmistha Mishra; Michael Jacobs; Stuart Dickson; G Marshall Lyon; Robert A Fowler
Journal:  Crit Care       Date:  2016-07-29       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.